5-53
5-10 User Parameters
5
Operating Functions
Internally Set Speed Control Parameters
These speed settings are used for Internally Set Speed Control.
Use internally set speeds No. 1 to No. 4 when Internally Set Speed Control is selected in the
Control Mode Selection (Pn02).
The sign of the setting indicates the direction of rotation. Settings with a plus sign (normally not
indicated) are for the forward direction, and settings with minus sign are for the reverse direction.
For details, refer to
Use this parameter to set the speed for jog operation.
For details, refer to
Set the acceleration or deceleration time for Internally Set Speed Control.
Set the time (setting
×
2 ms) required until the Servomotor rotation speed reaches 1,000 r/min or
until operation stops from 1,000 r/min.
Pn50
Not used. (Do not change setting.)
Pn51
Not used. (Do not change setting.)
Pn52
Not used. (Do not change setting.)
Pn53
No. 1 Internally Set Speed
Setting range
−
20000 to 20000
Unit
r/min
Default setting
100
Power OFF
→
ON
---
Pn54
No. 2 Internally Set Speed
Setting range
−
20000 to 20000
Unit
r/min
Default setting
200
Power OFF
→
ON
---
Internally set speed
Internally set speed
Pn55
No. 3 Internally Set Speed
Setting range
−
20000 to 20000
Unit
r/min
Default setting
300
Power OFF
→
ON
---
Internally set speed
Pn56
No. 4 Internally Set Speed
Setting range
−
20000 to 20000
Unit
r/min
Default setting
400
Power OFF
→
ON
---
Internally set speed
Pn57
Jog Speed
Setting range
0 to 500
Unit
r/min
Default setting
200
Power OFF
→
ON
---
All modes
Pn58
Soft Start Acceleration Time
Setting range
0 to 5000
Unit
×
2 ms
Default setting
0
Power OFF
→
ON
---
Pn59
Soft Start Deceleration Time
Setting range
0 to 5000
Unit
×
2 ms
Default setting
0
Power OFF
→
ON
---
Internally set speed
Internally set speed
ta
td
Internally Set Speed
Speed
1000 r/min