6-22
6-3 Using the Parameter Unit
6
Opera
tion
5. Returning to the Display of Copy Mode
Key operation
Display example
Explanation
Press the Data key to return to the Copy Mode Display.
ckfk_kck2ka.
If “Error” is displayed before completion, repeat the procedure from the
beginning.
Press the Data key to clear the error.
If an error is repeatedly displayed, the following are the possible causes:
cable disconnection, connector contact failure, incorrect operation due to
noise, or EEPROM fault in the Parameter Unit.
Do not disconnect the Parameter Unit from the Servo Drive while copying
is being performed.
If the Parameter Unit is disconnected, incorrect data may be written and
the data may be corrupted. Copy the user parameters again from the
source Servo Drive to the Parameter Unit, and then copy the user
parameters from the Parameter Unit to the other Servo Drive.
Precautions
for Correct Use