7-14
7-4 Disabling the Automatic Gain Adjustment Function
7
Adjustment Functions
Disabling the Adaptive Filter
Setting the Realtime Autotuning Mode Selection (Pn21) to 0 or 4 to 6 will disable the adaptive filter
which automatically adjusts for load resonance. If the properly functioning adaptive filter is disabled,
the effect of the suppressed resonance may appear, and noise and vibration may occur. Disable
the adaptive filter only after manually setting the Notch Filter 1 Frequency (Pn1D) based on the
displayed value of the Adaptive Filter Table Number Display (Pn2F).
When the Adaptive Filter Table Number Display (Pn2F) is greater than 49, the Realtime
Autotuning Machine Rigidity Selection (Pn22) may have automatically disabled the adaptive
filter. In this case, the Notch Filter 1 Frequency (Pn1D) does not need to be set.
Displayed
value
Notch Filter 1
Frequency (Hz)
Displayed
value
Notch Filter 1
Frequency (Hz)
Displayed
value
Notch Filter 1
Frequency (Hz)
0
Disabled
22
766
44
326
1
Disabled
23
737
45
314
2
Disabled
24
709
46
302
3
Disabled
25
682
47
290
4
Disabled
26
656
48
279
5
1482
27
631
49
269 (Disabled when Pn22
≥
F)
6
1426
28
607
50
258 (Disabled when Pn22
≥
F)
7
1372
29
584
51
248 (Disabled when Pn22
≥
F)
8
1319
30
562
52
239 (Disabled when Pn22
≥
F)
9
1269
31
540
53
230 (Disabled when Pn22
≥
F)
10
1221
32
520
54
221 (Disabled when Pn22
≥
E)
11
1174
33
500
55
213 (Disabled when Pn22
≥
E)
12
1130
34
481
56
205 (Disabled when Pn22
≥
E)
13
1087
35
462
57
197 (Disabled when Pn22
≥
E)
14
1045
36
445
58
189 (Disabled when Pn22
≥
E)
15
1005
37
428
59
182 (Disabled when Pn22
≥
D)
16
967
38
412
60
Disabled
17
930
39
396
61
Disabled
18
895
40
381
62
Disabled
19
861
41
366
63
Disabled
20
828
42
352
64
Disabled
21
796
43
339