5-43
5-10 User Parameters
5
Operating Functions
This parameter displays the table entry number corresponding to the frequency of the adaptive
filter.
This parameter is set automatically and cannot be changed if the adaptive filter is enabled in the
Realtime Autotuning Mode Selection (Pn21).
When the adaptive filter is enabled, data will be saved in EEPROM every 30 minutes. If the
adaptive filter is enabled the next time the power supply is turned ON, adaptive operation will start
with the data saved in the EEPROM as the default value.
To reset the adaptive filter when operation is not normal, set the Realtime Autotuning Mode
Selection (Pn21) to 0 or to between 4 and 6 and disable the filter, and enable it again.
If the display for this parameter is 49 or higher, the adaptive filter may be automatically disabled
depending on the Realtime Autotuning Machine Rigidity Selection (Pn22).
Explanation of Settings
Pn2F
Adaptive Filter Table Number Display
Setting range
0 to 64
Unit
---
Default setting
0
Power OFF
→
ON
---
Advanced position
Dis-
played
value
Notch Filter 1
Frequency (Hz)
Dis-
played
value
Notch Filter 1
Frequency (Hz)
Dis-
played
value
Notch Filter 1 Frequency (Hz)
0
Disabled
22
766
44
326
1
Disabled
23
737
45
314
2
Disabled
24
709
46
302
3
Disabled
25
682
47
290
4
Disabled
26
656
48
279
5
1482
27
631
49
269 (Disabled when Pn22
≥
F)
6
1426
28
607
50
258 (Disabled when Pn22
≥
F)
7
1372
29
584
51
248 (Disabled when Pn22
≥
F)
8
1319
30
562
52
239 (Disabled when Pn22
≥
F)
9
1269
31
540
53
230 (Disabled when Pn22
≥
F)
10
1221
32
520
54
221 (Disabled when Pn22
≥
E)
11
1174
33
500
55
213 (Disabled when Pn22
≥
E)
12
1130
34
481
56
205 (Disabled when Pn22
≥
E)
13
1087
35
462
57
197 (Disabled when Pn22
≥
E)
14
1045
36
445
58
189 (Disabled when Pn22
≥
E)
15
1005
37
428
59
182 (Disabled when Pn22
≥
D)
16
967
38
412
60
Disabled
17
930
39
396
61
Disabled
18
895
40
381
62
Disabled
19
861
41
366
63
Disabled
20
828
42
352
64
Disabled
21
796
43
339