4-25
CHAPTER 4 Adjustment
12) Perform the absolute reset from outside the safeguard enclosure.
13) After the absolute reset is completed, read the machine reference value dis-
played on the PB.
14) If the machine reference value is in the range between 40 and 60 (recom-
mended range), then the machine reference has been completely adjusted.
If it is outside the recommended range, then repeat the procedure that starts
in 5) to readjust it.
Summary of Contents for R6Y Series
Page 2: ......
Page 12: ......
Page 30: ......
Page 32: ......
Page 38: ......
Page 53: ...3 13 CHAPTER 3 Installation Fig 3 7 Ground terminal Ground symbol M4 Ground terminal...
Page 108: ......
Page 150: ...4 42 CHAPTER 4 Adjustment End effector R Y X z Fig 4 13 Positions for affixing the stickers...
Page 160: ......
Page 162: ......
Page 202: ......
Page 203: ...CHAPTER 6 Increasing the robot operating speed 1 Increasing the robot operating speed 6 1...
Page 204: ......
Page 210: ......
Page 212: ......
Page 215: ...7 3 CHAPTER 7 Specifications 1 2 External view and dimensions Fig 7 1 R6YXH250...
Page 216: ...7 4 CHAPTER 7 Specifications User tubing 1 f4 black User tubing 2 f4 red User tubing 3 f4 blue...
Page 217: ...7 5 CHAPTER 7 Specifications Fig 7 2 R6YXH350...
Page 218: ...7 6 CHAPTER 7 Specifications...
Page 219: ...7 7 CHAPTER 7 Specifications Fig 7 3 R6YXH400...
Page 221: ...7 9 CHAPTER 7 Specifications Fig 7 4 R6YXX1200...
Page 222: ...7 10 CHAPTER 7 Specifications...
Page 224: ...7 12 CHAPTER 7 Specifications Fig 7 6 R6YXX1200...
Page 225: ...7 13 CHAPTER 7 Specifications 1 4 Wiring table Robot cable wiring table...
Page 226: ...7 14 CHAPTER 7 Specifications...
Page 229: ...7 17 CHAPTER 7 Specifications Motor wiring table Motor X Y Motor Z R...
Page 230: ...7 18 CHAPTER 7 Specifications Resolver wiring table Resolver X Y Resolver Z R...