Event code
Event name
Meaning
Assumed cause
Level
Reference
M
a
j
P
rt
M
i
n
O
b
s
I
n
f
o
05220000 hex
Internal Cir-
cuit Error at
Test Output
A fault was detected
in the internal circuit
for the test output ter-
minal.
•
The internal circuit for the test
output terminal is faulty.
•
A memory error or signal error
occurred due to a transient
cause, such as an excessive
noise.
¡
05230000 hex
Internal Cir-
cuit Error at
Safety Out-
put
A fault was detected
in the internal circuit
for the safety output
terminal.
•
The internal circuit for the safe-
ty output terminal is faulty.
•
A memory error or signal error
occurred due to a transient
cause, such as an excessive
noise.
¡
65200000 hex
I/O Power
Supply Volt-
age Error
An incorrect I/O pow-
er supply voltage was
detected.
•
The input power or output
power is not supplied correctly.
¡
65210000 hex
Output Pow-
er Interrupt
Circuit Error
An error was detect-
ed by the output pow-
er interruption test.
•
The wiring is not correct or
there is a fault in the hardware.
¡
65220000 hex
External Test
Signal Fail-
ure at Safety
Input
An error was detect-
ed in test pulse evalu-
ation of the safety in-
put terminals.
•
The positive power supply wire
is in contact with the input sig-
nal line.
•
The input signal lines are
shorted.
•
The external device is faulty.
¡
65230000 hex
Discrepancy
Error at
Safety Input
An error was detect-
ed in discrepancy
evaluation of safety
input terminals.
•
There is a ground fault or dis-
connection in the input signal
line.
•
The connected device is faulty.
•
The setting of the discrepancy
time is not correct.
•
Chattering occurred in the in-
put signal from the external in-
put device, such as a safety
door.
¡
65240000 hex
Overload
Detected at
Test Output
An overcurrent was
detected at the test
output terminal.
•
There is a ground fault on the
output signal line.
•
The external device is faulty.
¡
65250000 hex
Stuck-at-
high Detect-
ed at Test
Output
It was detected that
the test output termi-
nal is stuck ON.
•
The positive power supply line
is in contact with the output
signal line.
•
The internal circuit is faulty.
•
A memory error or signal error
occurred due to a transient
cause, such as a software er-
ror or excessive noise.
¡
65270000 hex
Short Circuit
Detected at
Safety Out-
put
A ground fault was
detected on the safe-
ty output terminal.
•
There is a ground fault on the
output signal line.
¡
12 Troubleshooting
12 - 29
NX-series Safety Control Unit User's Manual (Z930)
12-3 Checking for Errors with the Sysmac Studio
12
12-3-3 Event Codes for Errors and T
roubleshooting Procedures
Summary of Contents for NX-SIH400
Page 4: ...Introduction 2 NX series Safety Control Unit User s Manual Z930 ...
Page 46: ...Revision History 44 NX series Safety Control Unit User s Manual Z930 ...
Page 108: ...2 Specifications 2 42 NX series Safety Control Unit User s Manual Z930 ...
Page 132: ...3 Installation and Wiring 3 24 NX series Safety Control Unit User s Manual Z930 ...
Page 148: ...4 Safety Control Unit Operation 4 16 NX series Safety Control Unit User s Manual Z930 ...
Page 216: ...5 System Configuration and Setup 5 44 NX series Safety Control Unit User s Manual Z930 ...
Page 306: ...6 Programming 6 90 NX series Safety Control Unit User s Manual Z930 ...
Page 390: ...8 Calculating Safety Reaction Times 8 12 NX series Safety Control Unit User s Manual Z930 ...
Page 412: ...11 Safety Data Logging 11 10 NX series Safety Control Unit User s Manual Z930 ...
Page 504: ...12 Troubleshooting 12 92 NX series Safety Control Unit User s Manual Z930 ...
Page 554: ...l I O Map Settings Appendices A 42 NX series Safety Control Unit User s Manual Z930 ...
Page 623: ...I Index I 1 NX series Safety Control Unit User s Manual Z930 I ...
Page 625: ......