Precautions for Correct Use
• The maximum number of connections per Unit is as follows:
NX-SIH400: 20 (10 connected in series × 2 series)
• You can connect up to 10 Non-contact Door Switches to each test output terminal.
• You cannot branch the connections to more than one Non-contact Door Switch from the
same test output terminal.
Non-contact Door Switches
24 VDC
0 V
White
Black
Blue
Brown
White
Black
Blue
Brown
NX bus connection
IOV
IOV
IOG
IOG
T0
Si0
Si1
Si3
Si2
NX-SI
o
The unit that supplies the I/O
power to the NX bus
• The total wiring length (L1 + L2 +…+ Ln+2 in the figure above) for the D40A or D40Z Non-
contact Switches is 100 m max.
• The D40A Non-contact Door Switch can be used in a Safety Category 3 or lower or a PLd or
lower application. It cannot be used in a Safety Category 4 or PLe application.
• The D40Z Non-contact Door Switch can be used in a Safety Category 4 or lower or a PLe or
lower application.
l
UM/UMA Safety Mats
OMRON UM/UMA Safety Mats are connected as shown in the following figure.
Safety mat
n pcs (n=12 max.)
Blue
White
Brown
Black Blue
White
Brown
Black
T0
NX-SIH400
T1
Si0
Si1
L
n + 1
L
1
L
2
L
n
L
3
Example of Sysmac Studio Settings:
4 Safety Control Unit Operation
4 - 19
NX-series Safety Control Unit User's Manual (Z930)
4-3
Safety I/O Function
4
4-3-1
Safety Input Function
Summary of Contents for NX-SIH400
Page 4: ...Introduction 2 NX series Safety Control Unit User s Manual Z930 ...
Page 46: ...Revision History 44 NX series Safety Control Unit User s Manual Z930 ...
Page 108: ...2 Specifications 2 42 NX series Safety Control Unit User s Manual Z930 ...
Page 132: ...3 Installation and Wiring 3 24 NX series Safety Control Unit User s Manual Z930 ...
Page 148: ...4 Safety Control Unit Operation 4 16 NX series Safety Control Unit User s Manual Z930 ...
Page 216: ...5 System Configuration and Setup 5 44 NX series Safety Control Unit User s Manual Z930 ...
Page 306: ...6 Programming 6 90 NX series Safety Control Unit User s Manual Z930 ...
Page 390: ...8 Calculating Safety Reaction Times 8 12 NX series Safety Control Unit User s Manual Z930 ...
Page 412: ...11 Safety Data Logging 11 10 NX series Safety Control Unit User s Manual Z930 ...
Page 504: ...12 Troubleshooting 12 92 NX series Safety Control Unit User s Manual Z930 ...
Page 554: ...l I O Map Settings Appendices A 42 NX series Safety Control Unit User s Manual Z930 ...
Page 623: ...I Index I 1 NX series Safety Control Unit User s Manual Z930 I ...
Page 625: ......