Modes
3
-
5
Modes
This section describes the Inverter's modes and switching between modes.
Inverter Modes
The Inverter's user parameters and monitoring functions are organized in groups called modes that make it
easier to read and set user parameters.The Inverter is equipped with 5 modes.
The 5 modes and their primary functions are shown in the Table 3.2.
*Always perform autotuning with the motor before operating using vector control. Autotuning Mode will not be displayed during operation or when an
error has occurred.
Table 3.2 Modes
Mode
Primary function(s)
Drive mode
The Inverter can be run in this mode.
Use this mode when monitoring values such as frequency references or output cur-
rent, displaying fault information or displaying the fault history.
Quick programming mode
Use this mode to reference and set the minimum user parameters to operate the
Inverter (e.g., the operating environment of the Inverter and Digital Operator).
Advanced programming mode
Use this mode to reference and set all user parameters.
Verify mode
Use this mode to read/set user parameters that have been changed from their fac-
tory-set values.
Autotuning mode*
Use this mode when running a motor with unknown motor parameters in the vector
control mode. The motor parameters are calculated and set automatically.
This mode can also be used to measure only the motor line-to-line resistance.