5
-24
Multi-function Analog Outputs: H4
* An analog output of 4-20 mA can not be used with the standard terminal board. Therefore an optional terminal board (with shunt connector CN15) is
needed.
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Access
Level
RS-422A/
485
Register
Page
LCD Dispay
H4-01
Monitor selec-
tion (terminal
FM)
Sets the number of the monitor
item to be output (U1-
) from
terminal FM.
10 to 14, 28, 34, 39, 40 cannot be
set.
1 to 38
2
No
A
41DH
6-50
Terminal FM
Sel
H4-02
Gain (termi-
nal FM)
Sets the multi-function analog
output 1 voltage level gain.
Sets whether the monitor item
output will be output in multiples
of 10 V.
The maximum output from the
terminal is 10 V. A meter calibra-
tion function is available.
0 to
1000
100%
Yes
Q
41EH
4-7
6-50
Terminal FM
Gain
H4-03
Bias (terminal
FM)
Sets the multi-function analog
output 1 voltage level bias.
Sets output characteristic up/
down parallel movement as a per-
centage of 10 V.
The maximum output from the
terminal is 10 V. A meter calibra-
tion function is available.
-110 to
+110
0.0%
Yes
A
41FH
4-7
Terminal FM
Bias
H4-04
Monitor selec-
tion (terminal
AM)
Sets the number of the monitor
item to be output (U1-
) from
terminal AM.
10 to 14, 28, 34, 39, 40 cannot be
set.
1 to 38
3
No
A
420H
4-7
6-50
Terminal AM
Sel
H4-05
Gain (termi-
nal AM)
Set the voltage level gain for
multi-function analog output 2.
Set the number of multiples of 10
V to be output as the 100% output
for the monitor items. The maxi-
mum output from the terminal is
10 V. A meter calibration func-
tion is available.
0 to
1000
50.0%
Yes
Q
421H
4-7
6-50
Terminal AM
Gain
H4-06
Bias (terminal
AM)
Sets the multi-function analog
output 2 voltage level bias.
Sets output characteristic up/
down parallel movement as a per-
centage of 10 V.
The maximum output from the
terminal is 10 V. A meter calibra-
tion function is available.
-110.0
to
+110.0
0.0%
Yes
A
422H
-
Terminal AM
Bias
H4-07
Analog output
1 signal level
selection
Sets the signal output level for
multi-function output 1 (terminal
FM)
0: 0 to +10 V output
2: 4 – 20 mA*
0 or 2
0
No
A
423H
-
AO Level
Select1
H4-08
Analog output
2 signal level
selection
Sets the signal output level for
multi-function output 2 (terminal
AM)
0: 0 to +10 V output
2: 4 – 20 mA*
0 or 2
0
No
A
424H
-
AO Level
Select2