5
-36
* This setting depends on the inverter capacity.
Copy Function: o3
Parameters for the copy function are shown in the following table.
T: Motor Autotuning
The following settings are made with the motor autotuning parameters (T parameters): Settings for autotuning.
o2-08
Cumulative
operation time
selection
0: Cumulative time when the
Inverter power is on. (All time
while the Inverter power is on
is accumulated.)
1: Cumulative Inverter run time.
(Only Inverter output time is
accumulated.)
0 or 1
0
No
A
50CH
-
Elapsed Time
Run
o2-09
Initialize Mode
2: European specification
5: PV-E specification
2 or 5
2
No
A
50DH
–
Init Mode Sel
o2-10
Fan operation
time setting
Set the initial value of the fan
operation time.
The operation time accumulates
from the set value.
0 to
65535
0 hr
No
A
50EH
6-80
Fan ON Time
Set
o2-12
Fault trace ini-
tialize
0: Disable
1: Initialize (= zero clear) after
setting ”1“ o2-12 will be returned
to ”0“
0 or 1
0
No
A
511H
-
FLT Trace Init
Param-
eter-
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Access
Level
RS-422A/
485
Register
Page
LCD
Display
o3-01
Copy function
selection
0: Normal operation
1: READ (Inverter to Operator)
2: COPY (Operator to Inverter)
3: Verify (compare)
0 to 3
0
No
A
515H
6-82
Copy Function
Sel
o3-02
Read permis-
sion selection
0: Read prohibited
1: Read permitted
0 or 1
0
No
A
516H
6-82
Read Allow-
able
Param-
eter
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Access
Level
RS-422A/
485
Register
Page
LCD
Display
T1-02
Motor output
power
Set the output power of the motor
in kilowatts.
0.00 to
650.00
0.40
kW
No
A
702H
4-8
Mtr Rated
Power
Param-
eter-
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Access
Level
RS-422A/
485
Register
Page
LCD
Display