H5CR
H5CR
175
Accessories (Order Separately)
Hard cover
Y92A-48
Soft cover
Y92A-48F1
Track mounted socket
P2CF-08
Rear surface connection socket
P3G-08
Shock prevention cover
Y92A-48T
Mounting Adapter
Y92F-30*
*Standard with unit
Adapter
Y92F-30
Shock Prevention Cover
(conforming to VDE0106/P100)
Y92A-48T
Soft Cover
Y92A-48F1
Hard Cover
Y92A-48
Specifications
Model
H5CR-L (Basic type)
H5CR-B (Standard type)
H5CR-S (Short body type)
Classification
Digital timer
Mounting
Panel or Surface mounting
Panel mounting
External connections
8P socket
Screw terminals
Enclosure ratings
IP40
IP54 (panel surface)
EMC
Emission Enclosure:
EN55011 Group 1 class A
Emission AC Mains:
EN55011 Group 1 class A
Immunity ESD:
IEC801-2:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference:
ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
IEC801-4:
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
Approvals
UL:
File no. E41515
CSA: File no. LR22310
Conforms to EN50081-2, prEN50082-2
Display modes
Elapsed time (UP), remaining time (DOWN)
Output modes
A, A-1, A-2, A-3, b, b-1, d, E, F
Reset system
Power reset (except A-3, b-1, and F modes), External, manual, automatic resets (internal according to
A-1, b, b-1, d, and E mode operation)
Input signals
Start, reset inputs
Start, reset, gate, key protect inputs
Input method
No-voltage input: Via opening and closing of contact
Control outputs
SPDT contact output and transistor output (NPN open collector)
Display
LCD without backlight
LCD with backlight
Digits
4 digits
Max. time settings
9.999 s (0.001 s units), 99.99 s (0.01 s units), 999.9 s (0.1 s unit), 9999 s (1 s unit), 99 min 59 s (1 s
unit), 999.9 min (0.1 min unit), 9999 min (1 min unit), 99 hr 59 min (1 min unit), 999.9 hr (0.1 hr unit),
9999 hr (1 hr unit)
Memory backup
Backup time for power interruption: Approx. 10 years at 20
"
C