H5L
H5L
256
Deleting Programming
1. Deleting from Normal Operation Programs (ON Time/
OFF Time)
Call up the output display for the program to be deleted by
pressing the Write Key. The minus sign (--) for the output point
will flash.
Next, change the display to disable the output using the Plus
and Minus Keys. For NC contacts, press the Plus Key and for
NO contacts, press the Minus Key. The connecting bar above
the contacts will disappear and the display will flash to indi-
cate that the output has been displayed. If the Write Key is
pressed at this time, the step will be deleted.
2. Deleting from Cyclic Programs
Four steps will be simultaneously deleted from the cyclic pro-
gram if the program is called up and then the Cycle and Write
Keys are pressed in order. The start time display will remain,
but the program will be deleted.
LCD Display
LCD Display (Display Example in Each Mode)
Since the H5L employs interactive programming, the program mode and setting data are displayed on the LCD.
Display
Mode
Display data
Display
Mode
Display data
RUN
Current day of week:
Monday
Current time:
10:11
First circuit:
OFF
Second circuit: ON
Second
operation
time setting
The second circuit turns
ON Sunday to Thursday
(operation by the set
program is executed). It
turns OFF on Friday and
Saturday (operation by
the set program stops).
Current time
setting
Current day of week:
Tuesday
Current time: 9:31
Second
Weekday
setting
The second circuit turns
ON Sunday to Thursday
(operation by the set
program is executed). It
turns OFF on Friday and
Saturday (operation by
the set program stops).
First
operation
time setting
The first circuit turns on
at 8:15
Cycle
Program
setting
The first circuit starts
cycle operation at 1:10
(for details, refer to
Cycle Program).
First weekday
setting
The first circuit turns
OFF on Sunday and
Saturday (operation by
the set program stops).
It turns ON Monday to
Friday (operation by the
set program is
executed).
Memory over
Indicates that all 16
program steps have
been written (on writing
the 16th step, the data
set for the first step is
displayed on the LCD).
Note:
Meaning of output status indications
:Output ON,
; Output OFF,
: Invalid (if an invalid instruction is written to a step, that step will be cleared.)
Programming Example
Be sure to create a timing chart before programming.
Operating Timing Chart
First Circuit
Second Circuit