132
Solid-state Timer
H3M
Solid-state Timer with Variable Time
Ranges
Four time ranges are selectable per timer unit.
Wide timing range of 0.05 second to 30 hours can
be covered by a combination of five timer units.
Standard surface mounting type is easily convert-
ible to flush mounting type with the use of a special
adapter (Y92F-40).
Requires only 40 x 50 mm for mounting space.
Equipped with power-ON & time-out indicators.
RC
Ordering Information
Operation/resetting system
Time-limit
t
t
Instantaneous
t
t
Mounting
p
/
g y
contact
contact
Surface mounting
Flush mounting
Time-limit operation/
lf
tti
DPDT
---
H3M
H3M with Y92F-40 adapter
p
/
self-resetting
SPDT
SPDT
H3M-H
H3M-H with Y92F-40 adapter
Note:
1. Specify both the model number and supply voltage when ordering.
2. Sockets and adapters for surface/track mounting are available optionally and therefore, place the order for them as necessary.
Timer hold-down clips (F-hook and L-hook) are supplied with the timer.
Accessories (Order Separately)
Adapter
Y92F-40
Specifications
Time Ranges
Four time ranges are available for each timer by changing the time range selector switch positions to different combinations.
Time range code
Time range selector switch
A
0.05 to 0.5 s
0.5 to 5 s
0.05 to 0.5 min
0.5 to 5 min
B
0.1 to 1 s
1 to 10 s
0.1 to 1 min
1 to 10 min
C
0.3 to 3 s
3 to 30 s
0.3 to 3 min
3 to 30 min
Time range code
Time multiplying key
D
0.1 to 1 min
1 to 10 min
0.1 to 1 hrs
1 to 10 hrs
E
0.3 to 3 min
3 to 30 min
0.3 to 3 hrs
3 to 30 hrs