4. Second Circuit Operation Setting
Press the Mode Key to place the H5L into PROG 2 mode. The display appears as shown on the left.
In this example, as the second circuit is to be cyclically operated, specify the cycle program by pressing
the Cycle Key.
Select the start time by setting the hour to 6 and the minute to 50 using pressing the Plus or Minus Key.
Write each set value by pressing the Write Key.
The timer will now wait for you to set the ON time (5 min in this example).
Press the Write Key to select 0 hrs, then use the Plus or Minus Keys followed by the Write Key to select 5 min.
The timer will now wait for the OFF time to be set (20 min in this example).
Press the Write Key to select 0 hrs, then use the Plus or Minus Keys followed by the Write Key to select 20 min.
The timer will now wait for the cyclic circuit operation stop time to be set (20:30 in this example).
Set the hour to 20 using the Plus or Minus Keys, then press the Write Key. Set the minutes to 30 and press the
Write Key again.
The programming of the cyclic operation is now complete. The timer will wait for input of a new program as
shown. We will now have to set the day of the week for the second circuit.
5. Second Circuit Day-of-the Week Setting
Press the Mode Key to place the H5L into PROG 2, DAY WET mode. Initially, all days of the week are selected
(shown by reverse video) and the SUN indicator will be flashing.
In our example, the second circuit is to be operated on all days except Sunday. To inhibit Sunday operation, press
the Minus Key while the SUN indicator is flashing. The circuit will now be operated only from Monday to Saturday.
All of the parameters have now been programmed for this example. Press the Mode Key to place the timer into
RUN mode. The display will be as shown (assuming five minutes have elapsed while programming). The output
status indicators indicate the status of each of the circuit.
Note:
Set manual override switches 1 and 2 to RUN.