background image

1

CONTENTS

Selection Guide

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Glossary

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Technical Information

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Standards

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Enclosure Ratings

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Timers

H3CR-A

16

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3CR-F/G/H

36

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3DR-A/P/M

65

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3DR-F/G/H

89

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3CA

109

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

New H3Y

123

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3M

132

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3FA

137

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3T

145

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5CL

151

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5BR

159

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5CR

174

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5AN

189

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5CN

201

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H2C

211

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H2A

219

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

STP

224

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5F

231

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5S

241

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5L

252

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H2F

265

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H2E

270

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H5RA

273

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3BA

280

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3BH

295

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3BG

301

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3BF

308

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Y92A-

jj

N Cover

313

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3G (see note)

316

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

H3CT (see note)

321

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Note: These products may not be available in certain areas.

Summary of Contents for H2A -

Page 1: ... A P M 65 H3DR F G H 89 H3CA 109 New H3Y 123 H3M 132 H3FA 137 H3T 145 H5CL 151 H5BR 159 H5CR 174 H5AN 189 H5CN 201 H2C 211 H2A 219 STP 224 H5F 231 H5S 241 H5L 252 H2F 265 H2E 270 H5RA 273 H3BA 280 H3BH 295 H3BG 301 H3BF 308 Y92A jjN Cover 313 H3G see note 316 H3CT see note 321 Note These products may not be available in certain areas ...

Page 2: ...O Life expectancy 20 x 106 operations 20 x 106 operations 20 x 106 operations 10 x 106 operations EMC Conforms to EN50081 2 prEN50082 2 Conforms to EN50081 2 prEN50082 2 Conforms to EN50081 2 prEN50082 2 Conforms to EN50081 2 prEN50082 2 Approved standards UL CSA conforms to VDE UL CSA conforms to VDE UL CSA conforms to VDE UL CSA conforms to VDE Page 16 37 43 51 Classification Solid state Timer M...

Page 3: ...50081 2 prEN50082 2 Conforms to EN50081 2 prEN50082 2 Approved standards UL CSA conforms to VDE UL CSA conforms to VDE UL CSA conforms to VDE Page 90 95 100 Classification Solid state Timer Model H3CA H3Y H3M Features DIN sized 48 x 48 mm 45 x 75 mm Timer with digital setting and LCD display multifunctions Subminiature Timer incorporating exclusive IC ideal for sequence control Solid state Timer w...

Page 4: ...UL CSA UL CSA Page 137 145 151 Classification Digital Timer Model H5BR H5CR H5AN Features 72 x 72 mm Timer with easy to use functions 1 16 DIN Timer with easy to use function DIN sized 72 x 72 mm Quartz Timer with multiple functions Appearance and dimensions 72 72 106 48 48 69 7 Time range 60 Hz 0 01 s to 9999 h 0 001 s to 9999 h 0 01 s to 9999 h Supply voltage 100 to 240 VAC 50 60 Hz 24 VAC 12 to...

Page 5: ...us SPDT SPDT SPST NO Life expectancy 10 x 106 operations 30 x 106 operations 1 x 106 operations Approved standards UL CSA UL CSA UL CSA Page 201 211 219 Classification Motor Timer Digital Daily Time Switch Weekly Time Switch Model STP H5F H5S Features Best selling Motor Timer with high repeat accuracy Easy to operate Daily Time Switch for various time control Weekly Time Switch for various time co...

Page 6: ...erations 2 years min 2 years min Approved standards UL CSA SEV UL CSA Page 252 265 270 Classification Others Model H5RA H3BA H3BH Features Replaces rotary cams for repeat pattern control DIN sized 48 x 48 mm 45 x 75 mm Timer with selectors to cover 64 specifications DIN sized 48 x 48 mm Power OFF delay Timer Appearance and dimensions Time range 60 Hz 0 01 s to 99 9 h 0 05 s to 100 h 0 05 s to 10 m...

Page 7: ... output 5 A at 250 VAC 5 A at 250 VAC 5 or 7 A at 250 VAC Contact fi ti Time limit SPST NO SPST NO DPDT SPDT DPDT configuration Instantaneous SPST NO Life expectancy 20 x 106 operations 20 x 106 operations 10 x 106 operations Approved standards UL CSA UL CSA UL CSA SEV Page 301 308 316 Classification Others Model H3CT Features DIN 48 x 48 mm standard size Analogue Timer Appearance and dimensions 6...

Page 8: ...ity Vibration The threshold of vibration beyondwhich anabnormality is expected to occur in the appearance or function of a device Mechanical Life Expectancy A life expectancy of a timer when the control output of the timer is operated under no load condition OFF delay Timer An output signal is generated upon application of a voltage to the operating circuit The output signal is removed after the l...

Page 9: ...ven operating time Repeat Cycle Cyclic Timer An output signal is generatedand removedrepetitively accordingto the times of the set ON and OFF while a voltage is being applied to the operating circuit T T T T Resetting Time Theperiodof timefrom theinterruptionof thevoltagesuppliedtothe operating circuit during or after the time limit operation until the re turn of the timer to its initial state Ope...

Page 10: ...ing contacts A A NO contacts NC contacts Normally closed contacts A pair of contacts which are normally closed when no relay input is applied A B B NC contacts Transfer contacts A B Transfer contacts NO and NC contacts which have a common contact terminal are collectively called transfer contacts A variety of contacts shown in A and B are all transfer contacts with NC contact arranged either on th...

Page 11: ...ons of approvals the listing mark and the recognition mark A Listing Mark constitutes a entirely approval of a product Products display the Listing Mark shown below LISTING MARK u TheRecognitionMarkapplies tothecomponentsusedinaproduct andthereforeconstitutes amore conditional approval of a product Products display the Recognition Mark shown below R RECOGNITION MARK This association descended from...

Page 12: ...yd s Register doesn t apply the passing mark on the product but in cludes it on the list of approved products that it publishes every year Automation equipment and devices receive tests and inspections based on the provisions of the steel ship regulations and can be formally approved if the tests are passed Testing at the production factory can be partially or entirely omitted whenautomation equip...

Page 13: ... CSA and the standards for each European country VDE SEMKO etc InNorthAmerica thetestsforloads otherthanresistiveloads arenormally performedwitha general purposeload witha0 75to0 80powerfactor but inEuropeancountriesthetestsareperformedwith an inductive load with a 0 4 power factor EMC Directive 89 336 EEC Concerning Electromag netic Compatibility The EMC Directive is a new approach directive layi...

Page 14: ...y test IEC801 2 1991 Electromagnetic compatibility for industrial process measurement and control equipment Part 2 Electrostatic discharge requirements IEC801 3 1984 Electromagnetic compatibility for industrial process measurement and control equipment Part 3 Radiated electromagnetic field requirements IEC801 4 1988 Electromagnetic compatibility for industrial process measurement and control equip...

Page 15: ...tted Spray water from all directions for one minute per m2 of external surface area and for a total time of no less than 3 minutes using the test device shown below 12 5 l min 2 5 to 3 m Discharging nozzle dia 6 3 6 Strong hosing jets from all directions Protected against strong jets of water e g for use on shipdecks limited ingress permitted Spray water from all directions for one minute per m2 o...

Page 16: ...self holding circuit or run monitoring with instantaneous contact Conforms to VDE0435 0110 and approved by UL and CSA Conforms to EMC standards Six language instruction manual provided RC Ordering Information Outputs Supply voltage 11 pin models 8 pin models Contact 100 to 240 VAC 50 60 Hz H3CR A H3CR A8 12 VDC 24 VDC VAC 50 60 Hz 48 to 125 VDC Transistor Photocoupler 12 VDC H3CR AS H3CR A8S 24 VD...

Page 17: ...ay output DPDT H3CR AS A8S Transistor output NPN PNP Relay output SPDT Instantaneous output type Relay output SPDT Mounting method DIN track mounting surface mounting and flush mounting EMC Emission Enclosure EN55011 Group 1 class A Emission AC Mains EN55011 Group 1 class A Immunity ESD IEC801 2 4 kV contact discharge level 2 8 kV air discharge level 3 Immunity RF interference ENV50140 10 V m 80 M...

Page 18: ... metal parts 2 000 VAC 50 60 Hz for 1 min between control output terminals and operating circuit 1 000 VAC 50 60 Hz for 1 min between contacts not located next to each other Impulse withstand voltage 3 kV between power terminals for 100 to 240 VAC 48 to 125 VDC 1 kV for 12 VDC 24 VDC VAC 4 5 kV between current carrying terminal and exposed non current carrying metal parts for 100 to 240 VAC 48 to ...

Page 19: ...hen Timer stops operating Operating mode display window Operating mode selector select a mode from A B B2 C D and E H3CR A and AS A and E H3CR A8 A8S A8EL A8E Scale range display windows Time unit display window Time unit selector select one from sec min hrs and 10h Time setting knob set time Output indicator orange Time range selector select one from 1 2 3 12 and 30 Operation Block Diagrams H3CR ...

Page 20: ...etting detection circuit Oscillation circuit Time range unit selectors Counting circuit Output circuit Indicator circuit Power ON indicator Output ON indicator Operating mode selector I O Functions Inputs Start Starts time measurement for A AS Reset Interrupts time measurement and resets time measurement value No time measurement is made and control output is OFF while the reset input is ON Gate P...

Page 21: ...plastic frame of the time setting knob Operating mode display window Time unit selector Time unit display window Time range selector Setting of Time Use the time setting knob to set the desired time Using the Setting Ring Setting a Specific Time Mount the Panel Cover on the Timer set the desired time with the time setting knob and place Time Setting Ring A onto the time set ting knob so that the t...

Page 22: ...elay NC Output relay NO Output indicator Power indicator t t B Flicker OFF start t t t Power Output relay NO Output indicator Power indicator t t a Start Reset Output relay NC t Basic operation Power Start Output t t t t B2 Flicker ON start Basic operation Power Start Output t t t t t t t t t a Power Start Reset Output relay NO Output indicator Power indicator Output relay NC t C Signal ON OFF del...

Page 23: ...eration Power Start Output t t a t t a t a t Output relay NC Power indicator Power Start Reset Output relay NO Output indicator E Interval Power Start Output t Basic operation Power Start Reset Output relay NC Power indicator t t t t a t a t Output relay NO Output indicator ...

Page 24: ...Power Start Reset Output relay NC Power indicator t t a t a t Is Is t 1 0 6 s Output Start Power Output relay NO Output indicator Note The G and J modes are special modes Order the H3CR A 300 special model for these modes Gate Signal Input Power Start Gate Reset Output relay ON OFF ON OFF ON OFF ON OFF ON OFF Note 1 This timing chart indicates the gate input in operating mode A ON delay operation ...

Page 25: ...Power indicator Output relay NO output indicator H3CR A8EL A8E Operating mode Timing chart A ON delay Power Output t Basic operation Power Output relay NC Power indicator Instantaneous output relay NC t Rt t Rt t a Instantaneous output relay NO Output relay NO output indicator E Interval Power Output relay NC Power indicator t Rt t Rt t a Instantaneous output relay NC Instantaneous output relay NO...

Page 26: ...nsions with Set Ring Dimensions with Flush Mounting Adaptor Y92F 30 Panel Cutout Note The adapters for two or more timers mounted in a vertical line are different in orientation from those mounted in a horizontal line N can be obtained as follows n the number of H3CR models arranged side by side Without a Cover N 48n 2 5 1 0 With the Protective Cover N 51n 5 5 1 0 With the Panel Cover N 50n 4 5 1 ...

Page 27: ...o 4 5 dia 52 to 53 76 0 2 65 to 66 R0 5 max R0 5 max 45 0 5 0 55 0 5 0 Note Themountingpanel thickness should be 1 to 3 2 mm 56 68 Track Mounting These dimensions vary with the kind of DIN track reference value 100 8 98 5 2 3 H3CR A H3CR AS H3CR A8 H3CR A8S H3CR A8E P2CF 11 P2CF 08 89 9 87 6 2 3 H3CR A8EL P2CF 08 100 7 98 4 2 3 H3CR A H3CR AS Adaptor H3CR A8 H3CR A8S H3CR A8E Y92F 30 P3GA 11 Y92F ...

Page 28: ... holes 70 max 50 max 20 3 max 7 8 3 4 5 35 4 Two 4 5 dia holes Eleven M3 5 x 7 5 sems 70 max 50 max 31 2 max 7 8 3 4 5 35 4 4 4 Back Connecting Socket P3G 08 P3GA 11 Terminal Arrangement Internal Connections Bottom View 45 27 dia 45 45 4 9 45 27 dia 25 6 4 5 16 3 6 2 17 Mounting Track PFP 100N PFP 50N PFP 100N2 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100N2 4 5 15 25 25 25 25 10 10 L 7 3 0 15 3...

Page 29: ...re are three types of Panel Covers Y92P 48GL Y92P 48GB and Y92P 48GM all of which are available in three colors Use the most suitable type of Panel Cover with the design of the scaling plate according to the application When setting a given time for the Timer use of the Y92S 27 or Y92S 28TimeSettingRingfacilitatesthetimesettingoperationand minimizes possible setting errors by operators The Time Se...

Page 30: ... A Contact Output H3CR AS Transistor Output H3CR A8 Contact Output H3CR A8S Transistor Output Power supply Reset input Start input Gate input Power supply Power supply Power supply Reset input Start input Gate input H3CR A8EL A8E Contact Output Power supply ...

Page 31: ...2 pin Operates with relay ON 12 to 24 VDC sensor power supply Sensor Timer Start reset gate Input 0 V No 2 pin Operates with transistor ON DC power supply Application Examples A Mode ON delay ON delay operation A mode is a basic mode 1 Power ON Start Power OFF Reset ThePower ONstart Power OFF resetoperationisastandardoper ating method Power 2 and 10 Start 2 and 6 Control output NC 8 and 11 NC 1 an...

Page 32: ...Power indicator t t t t t t t t Externally short circuited Flashing Lit Flashing Lit Flashing Lit Flashing Lit 2 Signal Start Signal Reset in B Mode If there is an abnormal signal flashing starts When the abnormal condition is restored a reset signal stops the display flashing Power supply Power 2 and 10 Start 2 and 6 Control output NC 8 and 11 NC 1 and 4 Control output NO 9 and 11 NO 1 and 3 Powe...

Page 33: ...g Start signal NC to NO t Power supply 2 Signal Start Instantaneous Operation Time limit Reset Lit Flashing Start signal NO to NC to NO Power supply t Power 2 and 10 Start 2 and 6 Control output NC 8 and 11 NC 1 and 4 Control output NO 9 and 11 NO 1 and 3 Power indicator Power continuously supplied E Mode Interval 1 Power ON Start Instantaneous Operation Time limit Reset This function is useful fo...

Page 34: ...ging of Setting NOTICE Do not change the time unit time range or operation mode while the timer is in operation or malfunction could result Power Supplies An AC power supply can be connected to the power input terminals without regardingpolarity A DCpowersupply must be connectedto the power input terminals as designated according to the polarity of the terminals A DC power supply can be connected ...

Page 35: ...ither NPN or PNP output is possible Environment WhenusingtheTimerinanareawithexcesselectronic noise sepa rate the Timer wiring and the equipment which generates the input signals as far as possible from the noise sources It is also recom mended to shield the input signal wiring to prevent electronic inter ference Organic solvents such as paint thinner as well as very acidic or basic solutions can ...

Page 36: ...functional Timer H3CR A H3CR AS H3CR A8 H3CR A8S H3CR A8E H3CR A8EL Twin Timer H3CR F H3CR FN H3CR F 300 H3CR FN 300 H3CR F8 H3CR F8N H3CR F8 300 H3CR F8N 300 Star delta Timer H3CR G8L H3CR G8EL Power OFF delay Timer H3CR HRL H3CR H8L H3CR H8RL H3CR H H3CR G H3CR F H3CR A Note 1 H3CR AS H3CR A8S Transistor output models 2 Refer to the H3CR A Datasheet L84 for details 11 pin model 8 pin model 8 pin...

Page 37: ...panel mounted with a socket 11 pin and 8 pin models are available RC Ordering Information Operating d Supply voltage 0 05 s to 30 h models 1 2 s to 300 h models p g modes 11 pin models 8 pin models 11 pin models 8 pin models Flicker OFF start 100 to 240 VAC H3CR F H3CR F8 H3CR F 300 H3CR F8 300 24 VAC DC 12 VDC 48 to 125 VDC Flicker ON start 100 to 240 VAC H3CR FN H3CR F8N H3CR FN 300 H3CR F8N 300...

Page 38: ...Group 1 class A Immunity ESD IEC801 2 4 kV contact discharge level 2 8 kV air discharge level 3 Immunity RF interference ENV50140 10 V m 80 MHz to 1 GHz level 3 Immunity Conducted Disturbance ENV50141 10 V 0 15 to 80 MHz level 3 Immunity Burst IEC801 4 2 kV power line level 3 2 kV I O signal line level 4 Approved standards UL508 CSA C22 2 No 14 LR NK Conforms to VDE0435 2021 VDE0110 Conforms to EN...

Page 39: ...0 to 240 VAC 48 to 125 VDC 1 kV for 12 VDC 24 VAC DC 4 5 kV between current carrying terminal and exposed non current carrying metal parts for 100 to 240 VAC 48 to 125 VDC 1 5 kV for 12 VDC 24 VAC DC Noise immunity 1 5 kV between power terminals square wave noise by noise simulator pulse width 100 ns 1 s 1 ns rise 400 V for 12 VDC Static immunity Malfunction 8 kV Destruction 15 kV Vibration resist...

Page 40: ...g knob with orange pointer For ON time setting OFF timesettingknob withgreenpointer For OFF time setting ON time unit display window ON time unit selector select one from sec 10 s min and hrs or from 10 s 10 min hrs and 10 h Operation Block Diagrams ON indicator OFF indicator Indicator circuit Power supply circuit One chip microcomputer Zero setting detection circuit Time range unit selectors ROM ...

Page 41: ... indicator tON ON set time tOFF OFF set time tOFF tON tOFF tON tOFF tOFF 0 1 s min Lit Not lit Lit Not lit Output NC ON OFF ON OFF Flicker ON start tON tON ON set time tOFF OFF set time Power ON OFF ON indicator OFF indicator tOFF tON tOFF tON tOFF 0 1 s min Lit Not lit Lit Not lit Output NO Output NC ON OFF ON OFF ...

Page 42: ... 300 H3CR F8N 300 66 6 0 7 17 4 37 dia 52 3 6 5 7 R1 3 14 dia 44 8 x 44 8 66 6 0 7 17 4 37 dia 52 3 6 5 7 R1 3 14 dia 44 8 x 44 8 48 48 48 48 Installation Terminal Arrangement Power supply Power supply H3CR F H3CR FN H3CR F 300 H3CR FN 300 H3CR F8 H3CR F8N H3CR F8 300 H3CR F8N 300 Note Leave terminals 5 6 and 7 open Do not use them as relay terminals ...

Page 43: ... 100 to 120 VAC H3CR G8L 200 to 240 VAC Time limit contact and instantaneous contact 100 to 120 VAC H3CR G8EL 200 to 240 VAC Note Specify both the model number and supply voltage when ordering Example H3CR G8L 100 to 120 VAC Supply voltage Model Number Legend H3CR 1 2 3 1 Classification G Star delta timer 2 Configuration 8 8 pin socket 3 Outputs None Star delta operation contact E Star delta opera...

Page 44: ...3CR G8L H3CR G8EL Functions Star delta timer Star delta timer with instantaneous output Pin type 8 pin Operating Reset method Time limit operation Self reset Output type Time limit SPST NO star operation circuit SPST NO delta operation circuit Time limit SPST NO star operation circuit SPST NO delta operation circuit Instantaneous SPST NO Mounting method DIN track mounting surface mounting and flus...

Page 45: ...trol output terminals and operating circuit 1 000 VAC 50 60 Hz for 1 min between contacts not located next to each other Impulse withstand voltage 3 kV between power terminals 4 5 kV between current carrying terminal and exposed non current carrying metal parts Noise immunity 1 5 kV between power terminals square wave noise by noise simulator pulse width 100 ns 1 ms 1 ns rise Static immunity Malfu...

Page 46: ...d current A 30 VDC L R 7 ms 250 VAC 30 VDC cosf 1 250 VAC cosf 0 4 Switching operations x 10 3 10 000 5 000 1 000 500 100 Nomenclature Scale range display windows Star operation indicator green Delta operation indicator orange Star operation time range selector select one from 6 12 60 and 120 Time unit display sec is fixed Time setting knob for setting star operation time Star delta transfer time ...

Page 47: ...r supply circuit Star operation time oscillation circuit Star operation time range selector Star operation time counting circuit Output circuit Indicator circuit Star operation indicator Delta operation indicator Star operation Delta operation Instantaneous output circuit AC input Star delta transfer time oscillation circuit Star delta transfer time counting circuit Star delta transfer time select...

Page 48: ...f the setting range and place Time Setting Ring C onto thetimesettingknobsothatthestopperof TimeSettingRingCisontheright edgeof thereset lockpositionofthePanelcover Next set thetime settingknobto20s theupperlimit of thesettingrange placeTimeSettingRingB ontothetimesettingknobsothatthestopperof TimeSetting Ring B is on the left edge of the reset lock position of the Panel Cover Stopper Reset lock p...

Page 49: ...esign of the scaling plate according to the application When setting a given time for the Timer use of the Y92S 27 or Y92S 28TimeSettingRingfacilitatesthetimesettingoperationand minimizes possible setting errors by operators The Time Setting Ring and Panel Cover should be used as a pair Setting a specific time Time Setting Ring A Y92S 27 and Panel Cover Y92P 48GL 48GB or 48GM Limiting the setting ...

Page 50: ...L H3CR G8EL Instantaneous contact Star operation contact Delta operation contact Star operation contact Delta operation contact Note Leave terminals 1 3 and 4 open Do not use them as relay terminals Note Leave terminal 4 open Do not use them as relay terminals ...

Page 51: ... H8L H3CR H8L 200 to 240 VAC 24 VAC DC 48 VDC 100 to 125 VDC With reset input 100 to 120 VAC H3CR HRL H3CR HRL 200 to 240 VAC 24 VAC DC 48 VDC 100 to 125 VDC SPDT 100 to 120 VAC H3CR H8RL H3CR H8RL 200 to 240 VAC 24 VAC DC 48 VDC 100 to 125 VDC Note Specify both the supply voltage and time unit code S or M in addition to the model number when ordering Example H3CR H8L 24 VAC DC M Supply voltage Ti...

Page 52: ...tage Output type Relay output DPDT Relay output SPDT Relay output DPDT Mounting method DIN track mounting surface mounting and flush mounting EMC Emission Enclosure EN55011 Group 1 class A Emission AC Mains EN55011 Group 1 class A Immunity ESD IEC801 2 4 kV contact discharge level 2 8 kV air discharge level 3 Immunity RF interference ENV50140 10 V m 80 MHz to 1 GHz level 3 Immunity Conducted Distu...

Page 53: ... 60 Hz for 1 min between control output terminals and operating circuit 1 000 VAC 50 60 Hz for 1 min between contacts not located next to each other Impulse withstand voltage 3 kV between power terminals for 100 to 120 VAC 200 to 240 VAC 100 to 125 VDC 1 kV for 24 VAC DC 48 VDC 4 5 kV between current carrying terminal and exposed non current carrying metal parts for 100 to 120 VAC 200 to 240 VAC 1...

Page 54: ... VAC 30 VDC cos 1 250 VAC cos 0 4 Switching operations x 10 3 10 000 5 000 1 000 500 100 Nomenclature Time range selector select one from 0 6 1 2 6 12 Output indicator red Scale range display windows Time unit display S series sec M series min Time setting knob for setting power OFF delay time Operation Block Diagrams Without Reset Input H3CR H8L LCD Time range selector Power supply circuit Oscill...

Page 55: ...it Power failure detection circuit Indicator circuit Input circuit AC DC input Reset input Output indicator I O Functions Inputs Reset Turns off the control output and resets the elapsed time Outputs Control output Operates instantaneously when the power is turned on and time limit resets when the set time is up after the power is turned off ...

Page 56: ...indicator Output 8 6 Power Reset input ON Short circuited OFF Open 0 05 s min 0 05 s min Rt Rt Output 8 5 H3CR HRL Power ON OFF Output 1 3 Output indicator Lit Not lit Output 1 4 Output 11 9 Output 11 8 Reset input Rt t Rt t 0 05 s min 0 05 s min Note t Set time Rt Minimum power ON time S series 0 1 s min M series 2 s min Dimensions Note All units are in millimeters unless otherwise indicated ...

Page 57: ...48 Installation Terminal Arrangement 8 pin Models Without Reset Input H3CR H8L With Reset Input H3CR H8RL 11 pin Model With Reset Input H3CR HRL Power supply Power supply Power supply Reset input Reset input Note Leave terminal 3 open Do not use them as relay terminals Note Leave terminal 6 open Do not use them as relay terminals ...

Page 58: ...tic frame of the time setting knob scale range display win dows For ON time the desired time unit sec 10 s min and hrs or 10 s 10 min hrs and 10 h is indicated in the ON time unit display win dow at the lower right corner of the front panel and can be changed by turning the ON time unit selector located below the ON time unit display window For OFF time the desired time unit sec 10 s min and hrs o...

Page 59: ...tioned is common for all H3CR F G H models Note All units are in millimeters unless otherwise indicated Dimensions with Flush Mounting Adaptor Y92F 30 Panel Cutout Note The adapters for two or more timers mounted in a vertical line are different in orientation from those mounted in a horizontal line N can be obtained as follows n the number of H3CR models arranged side by side Without a Cover N 48...

Page 60: ...uld be 1 to 3 2 mm 56 68 Track Mounting These dimensions vary with the kind of DIN track reference value 102 8 100 5 2 3 11 pin short body models eg H3CR F P2CF 11 P2CF 08 91 9 89 6 2 3 P2CF 08 100 7 98 4 2 3 Y92F 30 P3GA 11 Y92F 30 P3G 08 80 17 17 Flush Mounting 75 Y92F 30 P3G 08 15 85 4 P2CF 11 111 7 109 4 2 3 Y92F 30 P3GA 11 15 91 4 11 pin short body models eg H3CR F 8 pin short body models eg ...

Page 61: ... dia holes 70 max 50 max 20 3 max 7 8 3 4 5 35 4 Two 4 5 dia holes Eleven M3 5 x 7 5 sems 70 max 50 max 31 2 max 7 8 3 4 5 35 4 4 4 Back Connecting Socket P3G 08 P3GA 11 Terminal Arrangement Internal Connections Bottom View 45 27 dia 45 45 4 9 45 27 dia 25 6 4 5 16 3 6 2 17 Mounting Track PFP 100N PFP 50N PFP 100N2 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100N2 4 5 15 25 25 25 25 10 10 L 7 3 0 ...

Page 62: ... Socket Precautions Note The undermentioned is common for all H3CR F G H models Changing of Setting NOTICE Do not change the time unit time range or operation mode while the timer is in operation or malfunction could result Wiring H3CR H The H3CR has a high impedance circuit Therefore the H3CR may not be reset if the H3CR is influenced by inductive voltage In order to eliminate any influence of in...

Page 63: ...es a fixed value at once or the Timer may not be reset or a timer error could result For the power supply of an input device use an isolating transform er of which the primary and secondary windings are mutually iso lated and the secondary winding is not grounded H3CR Input terminal Power supply Circuit Isolation transformer is required Rectifier circuit The H3CR H has a large inrush current provi...

Page 64: ...hase or the terminals will be short circuited to one another refer to the figures below Incorrect Contact or transistor for external input signal H3CR series timer Input terminal Input terminal Power supply Power supply Correct Short circuit current Input terminal Input terminal Environment WhenusingtheTimerinanareawithexcesselectronic noise sepa rate the Timer wiring and the equipment which gener...

Page 65: ...odes cover a wide range of applications Enables easy sequence checks through instanta neous outputs for a zero set value at any time range Start reset and gate control inputs provided A wide time setting range of 0 10 s to 120 h Fine adjustment dial for accurate time settings Relay DPDT and Transistor Output Models are available H3DR P Multifunction Timer Six operating modes cover a wide range of ...

Page 66: ...me range Operating mode Model 100 to 240 VAC 50 60 Hz Contact DPDT 0 10 s to 120 h ON delay Flicker OFF start H3DR AP 12 VDC 7 multi range Flicker ON start Signal ON OFF delay 24 VDC VAC 50 60 Hz Signal OFF delay Interval 12 VDC Transistor 6 multi mode H3DR ASP 24 VDC VAC 50 60 Hz Photocoupler 100 to 120 VAC 50 60 Hz Contact SPDT H3DR PP 200 to 240 VAC 50 60 Hz 24 VDC VAC 50 60 Hz No input Models ...

Page 67: ... IEC801 2 4 kV contact discharge level 2 8 kV air discharge level 3 Immunity RF interference ENV50140 10 V m 80 MHz to 1 GHz level 3 Immunity Conducted Disturbance ENV50141 10 V 0 15 to 80 MHz level 3 Immunity Burst IEC801 4 2 kV power line level 3 2 kV I O signal line level 4 Approved standards UL508 CSA C22 2 No 14 Conforms to VDE 0435 2021 C 250 C 30 AS model VDE 0110 VDE0106 P100 IEC947 AC 15 ...

Page 68: ...C resistance load cos 1 Ambient temperature Operating 10 C to 55 C with no icing Storage 25 C to 65 C with no icing Ambient humidity Operating 35 to 85 Humidity class DIN 40 040 G PNP Voltage Input Models Item H3DR AP H3DR ASP H3DR PP Rated supply voltage 100 to 240 VAC 50 60 Hz 12 VDC 24 VDC VAC 50 60 Hz 12 VDC 24 VDC VAC 50 60 Hz 100 to 120 VAC 50 60 Hz 200 to 240 VAC 50 60 Hz 24 VDC VAC 50 60 H...

Page 69: ...min between current carrying terminal and non current carrying metal parts 2 000 VAC 1 000 VAC for AS model 50 60 Hz for 1 min between control output terminals and operating circuit 1 000 VAC 50 60 Hz for 1 min between contacts not located next to each other except AS model Impulse withstand voltage 3 kV between power terminals for 100 to 120 VAC 110 to 120 VAC 200 to 240 VAC 220 to 240 VAC 100 to...

Page 70: ...ated next to each other Impulse withstand voltage 3 kV between power terminals for 100 to 120 VAC 200 to 240 VAC 100 to 240 VAC 1 kV for 12 VDC 24 VDC VAC 4 5 kV between current carrying terminal and exposed non current carrying metal parts for 100 to 120 VAC 200 to 240 VAC 100 to 240 VAC 1 5 kV for 12 VDC 24 VDC VAC Noise immunity 1 5 kV between power terminals 400 V for 12 VDC and 600 V between ...

Page 71: ...1 5 kV between power terminals and 600 V between input terminals square wave noise by noise simulator pulse width 100 ns 1 s 1 ns rise Static immunity Malfunction 4 kV Destruction 8 kV Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude each in three directions Malfunction 10 to 55 Hz with 0 5 mm double amplitude each in three directions Shock resistance Destruction 980 m s2...

Page 72: ...ne tuning dial use to fine tune the set time Scale range display window Time unit display window Scale range display window Fine tuning dial use to fine tune the set time Power indicator green Flashes when Timer operates lit when Timer stops operating Time setting dial set time Operating mode selector select a mode from A B B2 C D and E Operating mode display window Name plate for user use 20 x 6 ...

Page 73: ... window Time unit display window Scale range display window Fine tuning dial use to fine tune the set time Power indicator green Flashes when Timer operates lit when Timer stops operating Time setting dial set time Operating mode selector select a mode from A B B2 C D and E Operating mode display window Name plate for user use 20 x 8 mm Time unit selector select one from sec min hrs and 10 h Outpu...

Page 74: ... input Input circuit Indicator circuit Power ON indicator Output ON indicator AC DC input Power supply circuit Zero setting detection circuit Oscillation circuit Time range unit selectors Counting circuit Operating mode selector Output circuit Start input Input circuit Indicator circuit Power ON indicator Output ON indicator H3DR P PP H3DR M AC DC input Power supply circuit Oscillation circuit Cou...

Page 75: ...curing positions or a malfunc tion could result from improper setting A Operating mode selector Groove for screwdriver Operating mode display window Selection of Operating Mode Turn the operating mode selector with a screwdriver until the de sired operating mode A B B2 C D or E appears in the display window located below the selector Selection of Time Unit and Time Scale The desired time unit s m ...

Page 76: ...ut relay NC t Output relay NO Output indicator For power on operation short circuit the start input and input common terminal The timer starts operating at the moment the power is turned on B2 Flicker ON start Basic operation Power Start Output t t t t t t t t t a Power Start see note Reset see note Power indicator Output relay NC t Output relay NO Output indicator For power on operation short cir...

Page 77: ...t see note Reset see note Output relay NC Power indicator t t t t a t a t Output relay NO Output indicator For power on operation short circuit the start input and input common terminal The timer starts operating at the moment the power is turned on Note For NPN Input Models Start stands for short circuited C1 and A2 and Reset stands for short circuited D1 and A2 ForPNPInputModels Start standsforv...

Page 78: ...moment the power is turned on Note 1 For NPN Input Models Start stands for short circuited C1 and A2 and Reset stands for short circuited D1 and A2 ForPNPInputModels Start standsforvoltageapplicationbetweenB1 andA2 and Reset stands forvoltageapplicationbetween C1 and A2 2 The G and J modes are special modes Order the H3DR Aj 300 special model for these modes Gate Signal Input Power Start Gate see ...

Page 79: ...y NO 15 to 18 output indicator Basic operation Power Start Output t t t t For power on operation short circuit the start input and input common terminal The timer starts operating at the moment the power is turned on B2 Flicker ON start Power A1 and A2 Start see note Output relay NC 15 and 16 Power indicator t t t t a t t t a Output relay NO 15 to 18 output indicator Basic operation Power Start Ou...

Page 80: ...nterval t a t t Power A1 and A2 Start see note Output relay NC 15 and 16 Power indicator t t a Output relay NO 15 to 18 output indicator Power Start Output t Basic operation For power on operation short circuit the start input and input common terminal The timer starts operating at the moment the power is turned on Note For NPN Input Models Start stands for short circuited C1 and A2 For PNP Input ...

Page 81: ...R P PP H3DR M H3DR A AS AP ASP Accessories Order Separately Mounting Track PFP 100N PFP 50N PFP 100N2 L Length 1 m PFP 100N 50 cm PFP 50N 1 m PFP 100N2 End Plate PFP M Spacer PFP S 4 5 15 25 25 25 25 10 10 L 7 3 0 15 35 0 3 27 0 15 1 4 5 15 25 25 25 25 15 10 10 L 35 0 3 27 24 16 29 2 1 1 5 50 11 5 M4 x 8 pan head screw 10 6 2 1 8 1 35 5 35 3 1 8 1 3 4 8 5 16 12 44 3 16 5 10 34 8 ...

Page 82: ...modes 6 modes thus uses a new timer contact symbols which are different from conventional ones used for other digital timers Power supply Reset B1 Start C1 Gate D1 A1 A2 H3DR A DPDT Relay Output H3DR P 15 16 18 Power supply Start C1 A1 A2 15 16 18 C1 A1 A2 Power supply A1 A2 Reset B1 Start C1 Gate D1 H3DR AS Transistor Output ...

Page 83: ...bolswhicharedifferentfromconventionalones used for other digital timers H3DR AP DPDT Relay Output H3DR PP 15 16 18 15 16 18 B1 A1 A2 H3DR ASP Transistor Output Power supply A1 A2 Reset C1 Start B1 Gate D1 Power supply A1 A2 Reset C1 Start B1 Gate D1 Power supply A1 A2 Start B1 No input Models H3DR M Power supply A1 A2 15 16 18 A1 A2 15 16 18 ...

Page 84: ... gate Input 0 V A2 Operates with transistor ON DC power supply H3DR P No voltage inputs No contact Input Connection to NPN open collector output sensor Contact Input No contact Input Connection to a voltage output sensor 12 to 24 VDC sensor power supply Sensor Timer Start Input 0 V A2 Operates with transistor ON DC power supply Timer Start Input 0 V A2 Operates with relay ON 12 to 24 VDC sensor po...

Page 85: ...n adequately switch 0 1 mA at 5 V H3DR PP Voltage inputs No contact Input for 24 VDC VAC Model Connection to PNP output sensor Contact Input Voltage Input Signal Levels No contact input Contact input 1 Transistor ON Residual voltage 1 V max Voltage between terminals B1 and A2 must be more than the operating voltage range 2 Transistor OFF Leakage current 0 01 mA max Voltage between terminals B1 and...

Page 86: ...ean voltage is within the rated operating voltage range of the Timer Connect the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value at once or the Timer may not be reset or a timer error could result For the power supply of an input device use an isolating transform er of which the primary and secondary windings are mutually iso lated and the second...

Page 87: ...rminal other than the commonterminal ortoapply voltageacross otherthan thespecified input andcommonterminals orthe internal circuits of the Timermay be damaged Power supply terminal A2 is a common terminal for the input sig nals S to the Timer Never use terminal A1 as the common ter minal for this purpose otherwise the internal circuit of the Timer may be damaged Do not connect a relay or any othe...

Page 88: ...rates the input signals as far as possible from the noise sources It is also recom mended to shield the input signal wiring to prevent electronic inter ference Organic solvents such as paint thinner as well as very acidic or basic solutions can damage the outer casing of the Timer Others If the Timer is mounted on a control board dismount the timer from the control board or short circuit the circu...

Page 89: ... identification and management Finger protection terminal block conforms to VDE0106 compatible with bar sleeve or fork connectors Delivered with an open terminal for quick installation Six language instruction manual provided Broad Line up of H3DR Series H3DR Standard Timer H3DR A AP H3DR AS ASP H3DR P PP H3DR M Twin Timer H3DR F Star delta Timer H3DR G Power OFF delay Timer H3DR H H3DR A P M Note...

Page 90: ... to 240 VAC H3DR F 48 VAC 24 VAC DC 12 VDC Note Specify both the model number and supply voltage when ordering Example H3DR F 24 VAC DC Supply voltage Model Number Legend H3DR j 1 1 Classification F Twin timers Specifications General Item H3DR F Operating mode Flicker OFF start Terminal block 5 terminals used Operating Reset method Time limit operation Time limit reset or self reset Output type Re...

Page 91: ... contacts not located next to each other Impulse withstand voltage 3 kV between power terminals for 100 to 240 VAC 1 kV for 12 VDC 24 VAC DC 48 VAC 4 5 kV between current carrying terminal and exposed non current carrying metal parts for 100 to 240 VAC 1 5 kV for 12 VDC 24 VAC DC 48 VAC Noise immunity 1 5 kV between power terminals square wave noise by noise simulator pulse width 100 ns 1 s 1 ns r...

Page 92: ...ns x 10 3 Load current A 30 VDC L R 7 ms 250 VAC cos 0 4 250 VAC 30 VDC cos 1 10 000 5 000 1 000 500 100 Nomenclature Note The output will change instantly if the setting dial is turned toward 0 ON indicator orange OFF indicator green Time scale selector x 0 1 x 1 For both ON time and OFF time OFF time setting dial OFF time unit selector select one from sec 10 s min and hrs Nameplate for user appl...

Page 93: ...ted above the window ON time unit display window ON time unit selector OFF time unit selector OFF time unit display window Time Scale Selection The scale 0 1 or 1 is selected with the time scale selector at the upper left cornerof thefront panel andappears inthewindowabove the selector Time range display window Time scale selector Time Setting Use the ON OFF time setting dial to set the ON OFF tim...

Page 94: ...e tOFF OFF set time Allow at least 0 1 s for recovery Power ON OFF Output 0 1 s min ON indicator OFF indicator ON OFF ON OFF ON OFF Dimensions Note All units are in millimeters unless otherwise indicated Installation Terminal Arrangement Power supply ...

Page 95: ...umber and supply voltage when ordering Example H3DR G 24 VAC DC Supply voltage Model Number Legend H3DR j 1 1 Classification G Star delta timer Specifications General Item H3DR G Terminal block 6 terminals used Operating Reset method Time limit operation Self reset Output type Time limit SPST NO star operation circuit SPST NO delta operation circuit Mounting method DIN track mounting Approved stan...

Page 96: ...rrent carrying terminal and exposed non current carrying metal parts for 100 to 240 VAC 1 5 kV for 24 VAC DC 48 VAC Noise immunity 1 5 kV between power terminals square wave noise by noise simulator pulse width 100 ns 1 s 1 ns rise Static immunity Malfunction 4 kV Destruction 8 kV Vibration resistance Destruction 10 to 55 Hz with 0 75 mm single amplitude each in three directions Malfunction 10 to ...

Page 97: ...ations x 10 3 Load current A 30 VDC L R 7 ms 250 VAC cos 0 4 250 VAC 30 VDC cos 1 10 000 5 000 1 000 500 100 Nomenclature Note The fine adjustment dial affects the setting on the main dial Star operation indicator green Delta operation indicator orange Star operation time scale selector x 1 s x 10 s Nameplate for user application 20 x 6 6 white panel Time setting dial for setting star operation ti...

Page 98: ...me Setting Use the main dial to set the operation time The fine tuning dial is useful whendelicate ormore accurateadjust ment is required Block Diagram AC DC input Power supply circuit Star operation indicator Delta operation indicator Indicator circuit Output circuit Star opera tion time oscillation circuit Star opera tion time counting circuit Star operation time range selector Star delta transf...

Page 99: ...OFF 0 5 s min Star operation contact Delta operation contact ON OFF ON OFF Star operation indicator Delta operation indicator ON OFF ON OFF Dimensions Note All units are in millimeters unless otherwise indicated Installation Terminal Arrangement Power supply Star operation contact Delta operation contact ...

Page 100: ...th the model number and supply voltage when ordering Example H3DR H 24 VAC DC S Supply voltage Time span code Model Number Legend H3DR j 1 1 Classification H Power OFF delay timer Specifications General Item H3DR H Operating mode Power OFF delay Terminal block 5 terminals used Operating Reset method Instantaneous operation Time limit reset Output type Relay output SPDT Mounting method DIN track mo...

Page 101: ... 60 Hz for 1 min between control output terminals and operating circuit 1 000 VAC 50 60 Hz for 1 min between contacts not located next to each other Impulse withstand voltage 3 kV between power terminals for 100 to 120 VAC 200 to 240 VAC 1 kV for 24 VAC DC 48 VAC DC 4 5 kV between current carrying terminal and exposed non current carrying metal parts for 100 to 120 VAC 200 to 240 VAC 1 5 kV for 24...

Page 102: ... 30 VDC L R 7 ms 250 VAC cos 0 4 250 VAC 30 VDC cos 1 10 000 5 000 1 000 500 100 Nomenclature Note The fine adjustment dial affects the setting on the main dial Time scale selector x 0 1 x 1 or x 1 s x 10 s Time setting dial for setting power OFF delay time Nameplate for user application 20 x 6 6 white panel Fine adjustment dial Power indicator green ...

Page 103: ...o set the operation time The fine tuning dial is useful whendelicate ormore accurateadjust ment is required Block Diagram AC DC input Power supply circuit Indicator circuit Output circuit Power failure detection circuit Oscillation circuit Counting circuit Time range selector I O Functions Inputs Reset Turns off the control output and resets the elapsed time Outputs Control output Operates instant...

Page 104: ...mum power On time S series 0 1 s min L series 0 3 s min The output may never turn ON if a value equal to or less than this value is used Power ON OFF Output OFF indicator ON OFF ON OFF Dimensions Note All units are in millimeters unless otherwise indicated ...

Page 105: ...H3DR H H3DR H 105 Installation Terminal Arrangement Power supply ...

Page 106: ...re in millimeters unless otherwise indicated Accessories Order Separately Mounting Track PFP 100N PFP 50N L Length 1 m PFP 100N 50 cm PFP 50N 4 5 15 25 25 25 25 10 10 L 7 3 0 15 35 0 3 27 0 15 1 End Plate PFP M Spacer PFP S 50 11 5 M4 x 8 pan head screw 10 6 2 1 8 1 35 5 35 3 1 8 1 3 4 8 5 16 12 44 3 34 8 16 5 10 ...

Page 107: ...all theremay be delays in turning ON the output Inrush Current Model Voltage Applied voltage Inrush current peak value Time H3DR F 12 VDC 13 2 VDC 50 mA 10 ms max 24 VAC DC 26 4 VAC 10 ms max 26 4 VDC 0 51 A 10 ms max 48 VDC 52 8 VAC 0 79 A 10 ms max 100 to 240 VAC 264 VAC 0 54 A 10 ms max H3DR G 24 VAC DC 26 4 VAC 0 79 A 5 ms max 26 4 VDC 0 54 A 10 ms max 48 VDC 52 8 VAC 0 54 A 5 ms max 100 to 24...

Page 108: ...eset by turningthem eitherclock wise or counterclockwise The switches are designed to click into place Be sure that the switches areintheproperplaceand donot leavethem betweenset tings Leaving switches between settings can cause faulty opera tion Wiring H3DR H The H3DR has a high impedance circuit Therefore the H3DR may not be reset if the H3DR is influenced by inductive voltage In order to elimin...

Page 109: ...operation p socket SPDT SPDT H3CA 8H H3CA 8H Note 1 Specify both the model number and supply voltage when ordering for the H3CA 8H and H3CA 8 2 The operation resetting system depends on the selected operation mode For details see Timing Chart 3 The 8 operation modes are as follows A ON delay operation B Repeat cycle operation C Signal ON OFF delay operation 1 D Signal OFF delay operation 1 E Inter...

Page 110: ... 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 100 m s2 approx 10G Ambient temperature Operating 10 C to 55 C Ambient humidity Operating 35 to 85 Life expectancy Mechanical 10 000 000 operations min unde...

Page 111: ...icker operation C Signal ON OFF delay operation 1 D Signal OFF delay operation 1 E Interval operation F One shot and flicker operation G Signal ON OFF delay operation 2 H Signal OFF delay operation 2 Operation Timing Chart H3CA A FA ON delay Operation A Mode Signal Start t Set time t a Time within the set time t Set time R Resetting time t a Time within the set time Power ON Start Power OFF Reset ...

Page 112: ...ote The minimum signal input time is 0 05 s One shot and Flicker Operation F Mode Signal Start Power ON Start Power OFF Reset Note The minimum signal input time is 0 05 s t Set time t a Time within the set time t Set time t a Time within the set time Note The minimum signal input time is 0 05 s Signal ON OFF delay Operation 2 G Mode Signal ON OFF delay Operation 2 H Mode Note 1 The minimum signal ...

Page 113: ... will enter the next control state Also while a check signal is being input the elapsed time measurement of the set time is not performed ON delay Operation Repeat Cycle Operation Note 1 This timing chart indicates the gate input in opera tion mode A ON delay operation 2 The set time is the sum of t1 and t2 t Set time t a Time within the set time t Set time t a Time within the set time H3CA 8H ...

Page 114: ...di mension L between two adjacent timers shouldbe 10 mm min N Accessories Order Separately Mounting Holes Note P2CF 11canbeused as a front connecting socket Track Mounted Front Connecting Socket P2CF 11 Terminal Arrangement Top View Mounting Height of Timer with Socket Two 4 5 dia mounting holes Two 4 5 dia holes Eleven M3 5 x 7 5 sems P2CF 08 Two 4 5 dia holes Two 4 5 dia or Two M4 Eight M3 5 x 7...

Page 115: ... with Socket P3G 08 86 3 10 9 Mounting Holes Terminal Arrangement Bottom View Mounting Height of Timer with Socket PL11 Approx 20 5 Two 3 5 dia or M3 socket mounting holes Two 2 dia holes M3 5 P3G 08 35 max Two 2 dia holes Mounting Holes Terminal Arrangement Bottom View Mounting Height of Timer with Socket PL08 Two 3 5 dia or 3M socket mounting holes 27 dia 79 6 ...

Page 116: ...woormoretimers inavertical or horizontal line Protective Cover Y92A 48B Y92A 48D The protective cover protects the front panel particularly the time setting section against dust dirt and water drip as well as prevents the set value from being altered due to accidental contact with the time setting knob Y92A 48D Hard Plastic Cover Y92A 48D Soft PVC Cover Note The Y92A 48B Protective Cover is made o...

Page 117: ...the check input contact between ter minals C and D For each signal input contact use a gold plated contacts with high reliability Be sure that these input signals satisfy the following re quirements aresistanceof 1k max andaresidual voltageof 1V max when the contact is made Solid state Signal Inputs Connect the start input transistor between terminals C and F the re set input transistor between te...

Page 118: ... when it goes from a high to low level Again the residual voltage should be 1 V max when the transistor is ON As the current output from the timer to Tr isapproximately0 1mA thisconnectionis possibleprovidedthere sidual voltage is kept to a maximum of 1 V Solid state circuit proximity sensor photoelectric sensor etc Note Except for the power supply circuitry avoid the laying of in put signal wires...

Page 119: ...y Operation A Mode Power ON Start Power OFF Reset Signal Start Signal Reset or Flicker Operation B Mode Power ON Start Power OFF Reset Signal Start Signal Reset Signal ON OFF delay Operation 1 C Mode Signal ON OFF start Instantaneous Operation Time limit Reset t Set time t a Time within the set time Signal OFF delay Operation 1 D Mode Signal Start Instantaneous Operation Time limit Reset or or or ...

Page 120: ...it Reset Signal Start Signal Reset Interval Operation E Mode Power ON Start Power OFF Reset Signal Start Signal Reset One shot and Flicker Operation F Mode Power ON Start Power OFF Reset Signal OFF delay Operation 2 H Mode Signal Instantaneous Operation Time limit Reset or or or or or or or or or or or or ...

Page 121: ...CA A and H3CA FA be sure that there is no inductive voltage or residual voltage applied to the timer power supply terminals 2 and 10 or A1 and A2 when the power switch is turned OFF Inductive voltage can be generated in the power supply line if it is placed in parallel with high voltage or power lines A DC power supply can be connected if its ripple factor is 20 or less and the mean voltage is wit...

Page 122: ...H3CA FA Timer on a socket mounting track ob serve the following procedures Mounting First hook portion A of the timer to an edge of the track and then de press the timer in direction B B A C Dismounting Pull out portion C with a round blade screwdriver and remove the timer from the mounting track ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To conv...

Page 123: ... h 24 100 to 120 200 to 230 VAC 50 60 Hz 12 24 48 125 100 to H3Y 2 H3Y 2 0 self resetting 4PDT 12 24 48 125 100 to 110 VDC H3Y 4 H3Y 4 0 Note Specify both the model number supply voltage and rated time when ordering Ex H3Y 2 100 to 120 VAC 0 5 s Rated time Supply voltage Accessories Order Separately Timer Track mounted socket t 1 Back connecting socket see note 1 Solder terminal Wire wrap terminal...

Page 124: ...elay ON 0 9 W at 24 VDC Relay OFF 0 07 W at 24 VDC 48 VDC Relay ON 1 0 W at 48 VDC Relay OFF 0 2 W at 48 VDC 100 to 110 VDC Relay ON 1 3 W at 110 VDC Relay OFF 0 3 W at 110 VDC 125 VDC Relay ON 1 3 W at 125 VDC Relay OFF 0 3 W at 125 VDC Control outputs H3Y 2 0 5 A at 250 VAC resistive load cos 1 H3Y 4 0 3 A at 250 VAC resistive load cos 1 Note 1 With DC ratings single phase full wave rectified po...

Page 125: ...y Mechanical 10 000 000 operations min under no load at 1 800 operations h Electrical H3Y 2 500 000 operations min 5 A at 250 VAC resistive load at 1800 operations h H3Y 4 200 000 operations min 3 A at 250 VAC resistive load at 1800 operations h Impulse withstand voltage Between power terminals 3 kV for 100 to 120 VAC 200 to 230 VAC 100 to 110 VDC 125 VDC 1 kV for 12 VDC 24 VDC 48 VDC Between expo...

Page 126: ...switched if L R is 7 ms In both cases a life of 100 000 operations can be expected The minimum applicable load is 1 mA at 5 VDC P reference value Reference A maximum current of 0 5 A can be switched at 125 VDC cos 1 Maximum current of 0 2 A can be switched if L R is 7 ms In both cases a life of 100 000 operations can be expected The minimum applicable load is 1 mA at 1 VDC P reference value 250 VA...

Page 127: ...meters unless otherwise indicated Timers H3Y 2 H3Y 4 63 0 6 4 6 3 63 0 6 4 6 3 28 max 21 5 max 21 5 max 28 max Mounting Holes H3Y 2 0 H3Y 4 0 H3Y 4 CB 0 Fourteen 1 3 dia holes Eight 1 3 dia holes Mounting Holes 60 7 28 max 60 7 28 max 6 3 21 5 max 6 3 21 5 max ...

Page 128: ...4A Mounting Holes Fourteen M3 8 sems Two 4 2 5 mounting holes Two 4 5 dia M4 or M3 6 72 max 29 5 max 30 max 16 5 35 4 3 4 4 6 59 0 3 22 0 2 PYF08A N Terminal Arrangement Mounting Holes for Surface Mounting 4 1 8 5 12 9 14 14 13 42 44 12 14 41 11 A2 A2 A1 19 8 3 2 dia 3 6 dia 4 42 8 44 1 12 5 14 41 12 A2 14 11 9 A1 13 A2 14 22 max 66 5 max PYF 08A N 30 max 4 3 2 1 8 7 6 5 12 11 10 9 14 14 13 20 8 T...

Page 129: ...ee note Note With PYjQN 2 dimension should read 20 max and dimension 36 5 max 29 5 max 25 5 max 24 max 0 3 2 7 7 7 20 max 2 6 2 7 29 5 max 41 5 max see note 25 max 24 max 22 max H3Y Series PYj PYj 02 PYjQN 2 29 5 max 25 5 max 22 max 0 3 2 7 4 3 16 5 max 2 PY08 02 PY14 02 59 3 21 4 0 2 0 Terminal Arrangement Bottom View Terminal Arrangement Bottom View PY08QN PY08QN 2 PY14QN PY14QN 2 PY08 PY14 25 8...

Page 130: ...Y08QN 2 PY14QN 2 PYP 1 PYP 18 Note PYP 18 may be cut to any desired length PYP 1 Two 3 4 dia holes PYP 18 Relay Hold down Clips Y92H 3 for PYFjA Socket Y92H 4 for PYj Socket Mounting Track PFP 100N PFP 50N see note 1 End Plate PFP M 1000 500 See note 2 Note 1 Meets DIN EN50022 2 This dimension applies to PFP 50N Spacer PFP S ...

Page 131: ...h as an MY Relay in combination H3Y Auxiliary relay MY Relay Do not use the H3Y in places where there is excessive dust corro sive gas or direct sunlight Do not mount more than one H3Y closely together otherwise the internal parts may become damaged Make sure that there is a space of 5 mm or more between any H3Y Models next to each other to allow heat radiation The internal parts may become damage...

Page 132: ...ing SPDT SPDT H3M H H3M H with Y92F 40 adapter Note 1 Specify both the model number and supply voltage when ordering 2 Sockets and adapters for surface track mounting are available optionally and therefore place the order for them as necessary Timer hold down clips F hook and L hook are supplied with the timer Accessories Order Separately Adapter Y92F 40 Specifications Time Ranges Four time ranges...

Page 133: ...0 Hz for 1 min between contact and control circuit 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 100 m s2 approx 10G Ambient temperature Operating 10 C to 50 C Storage 25 C to 65 C Ambient humi...

Page 134: ... at the same time after the lapse of theset time besuretolimit thecarry current toless than1A Whenusing thetimers at an ambient temperature of more than 40 C be sure to reset the timers immediately after the set time has elapsed Track Mounted Front Connecting Socket PF085A Terminal Arrangement Top View Mounting Holes Mounting Height of Timer with Socket Eight M3 5 7 sems Two 4 5 dia holes Four 5 d...

Page 135: ... Height of Timer with Socket Two 3 5 dia or M3 socket mounting holes Two 2 dia holes Terminal Arrangement Bottom View Mounting Holes Mounting Height of Timer with Socket Back Connecting Socket PL08 Mounting Track PFP 100N PFP 50N End Plate PFP M Note This dimension applies to PFP 50N Spacer PFP S See note Hold down Clips Attached PHC 1 For PF085A F fook ...

Page 136: ...o 240 VAC specifications Using these power supplies can damage internal circuits How to Change the Time Range The H3M is provided with two time range selector switches One is on the lower right side A of the front panel and the other on the lower left side Changethepositional combinationof thetimerangeselec tor switches with a flat blade screwdriver as desired A Caution Be sure to turn the power o...

Page 137: ...ternal resetting OFF delay operation by external signal Solid state output 1 s to 10 min H3FA SA OFF delay operation by external signal power OFF resetting 6 s to 60 min H3FA SB Instantaneous operation time limit resetting d t l tti l t t Contact output SPST NO SPST NC 1 s to 10 min H3FA AU p g and external resetting pulse output p SPST NO SPST NC 6 s to 60 min H3FA BU Solid state output 1 s to 10...

Page 138: ...50 60 Hz for 1 min between current carrying and non current carrying metal parts and between contact and control circuit see note 2 1 000 VAC 50 60 Hz for 1 min between non continuous contacts see note 2 Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 100 ...

Page 139: ...ower supply short circuit terminals 13 and 15 Note 1 Control output is provided when the set time T1 T2 or T3 T4 is up 2 Whenusingthe12 24VDCoperatedtimerwith a 12 VDC power supply short circuit terminals 13 and 15 Note When using the 12 24 VDC operated timer with a 12 VDC power supply short circuit terminals 13 and 15 Note 1 When using the 12 VDC operated timer suffixed SjU short circuit terminal...

Page 140: ...e External resistor M External resistor M H3FA A U SA U H3FA B U SB U When Prolonging Reset Time The time unit has a shorter reset time than conventional timers so that it canbe usedin combinationwith solid statecircuit Toprolong thereset time of the time unit while it is in operation to about 100 ms connect a capacitor having the listed constant to the time unit as shown below Since the reset tim...

Page 141: ...Mounting Holes Top View H3FA A B H3FA SA SB Applicable Connecting Socket Standard 24 pin IC socket can be used for mounting the time unit H3FA AU H3FA BU H3FA SAU H3FA SBU Mounting Holes Top View H3FA AU BU H3FA SAU SBU Applicable Connecting Socket Standard 24 pin IC socket can be used for mounting the time unit Thirteen 1 0 dia holes Thirteen 1 0 dia holes ...

Page 142: ... 140 When operating an external reset input contact short circuit termi nals A and D In this case the current that flows from terminal D to terminal Ais approx 0 1mA Therefore useofahigh reliabilitycon tact is recommended for the reset input Contact Output Top View Solid state Output Top View When using the 12 24 VDC operated timer with a 24 VDC power supply open terminals 13 and 15 Integration Op...

Page 143: ...A and X short circuit terminals M and O when using the 12 24 VDC operated timer with 12 VDC power supply and start input application short circuit terminals F and A output is produced immediately and is reset when the set time has elapsed While operating the timer unit if a reset input is applied a start input terminals F and A are open the time unit stops operating and the output is reset When op...

Page 144: ...t is approx 0 1 mA Therefore use of a high reliability contact is recommended for start and reset inputs Contact Output Top View Solid state Output Top View When using the 12 24 VDC operated timer with a 24 VDC power supply open terminals 13 and 15 Precautions Operating Refer to the diagram below for variations in the operate time with re spect to the set value Operate time Set value Others When c...

Page 145: ... Integrating operation power OFF resetting and external resetting OFF delay operation by external signal Power OFF resetting 6 s to 60 min multi H3T B Note 1 Time specifications differ for H3T A and H3T B 2 The desired operation resetting system is selected by short circuiting and opening the specified terminals 3 A 24 pin IC socket can be used for mounting the time unit 4 The number of terminals ...

Page 146: ...tage of FS value Influence of temperature 5 max at 10 C to 70 C Percentage of FS value Insulation resistance 100 M min at 250 VDC Dielectric strength 500 VAC 50 60 Hz for 1 min between all terminals knob and case Vibration resistance Destruction 10 to 55 Hz with 1 5 mm double amplitude Malfunction 10 to 55 Hz with 1 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunct...

Page 147: ... cannot be used Note Terminal 22 cannot be used Power S1 13 to 14 or 13 to 14 15 ON OFF ON 1 ms Reset input S2 1 to 13 Control output 11 to 12 Set time Set time 24 VDC 24 VDC Integration Operation The variable resistor connection can be opened to interrupt the tim er operation thus enabling integration operation Interrupt the timer operation by opening the connection between terminals 21 and 22 wh...

Page 148: ...he terminal section by the dotted line 24 VDC 1 mA 1 mA External Resistor and Operate Time Whenusinganexternal resistor refertothecharacteristicdiagrams shown below Use an external resistor rated at about 0 1 W 2 M Pay attention to external noise and keep the lead length to less than 2 m Since the characteristic diagrams represent standard data the op eratetimefactory settingmay not always be unif...

Page 149: ...When thevaluesetinthetimingcircuitiscounted anoutput signalis generated This signalis amplifiedby atransistortooperatetheload Thevoltage created across the load is the input voltage minus the forward voltage drop of the transistor and diode Note 1 A diode is connected internally to adsorb surge voltage generated by the output relay 2 Terminals 12 and 14 are internally connected 3 There are no time...

Page 150: ...5 min set the time range to 6 s adjust the knob to 5 s and then change the time range to 6 min The case is made of PBT which has good resistance to chemicals and will not be affected if cleaned at room temperature for short durations of time The structure of the Unit however does not allow for submersed cleaning Models with exposed internal variable resistors can malfunction if the moving parts co...

Page 151: ...revention Cover Contact output 100 to 240 VAC H5CL A 12 to 24 VDC H5CL AD H5CL AD 500 Transistor output Ph t l 100 to 240 VAC H5CL AS p Photocoupler 12 to 24 VDC H5CL ADS Model Number Legend H5CL A 2 3 1 Fixed 2 D DC Supply Voltage 3 S Transistor output 1 Accessories Order Separately Name Model Soft Cover Y92A 48F1 Hard Cover Y92A 48 Shock Prevention Cover for DC models only Y92A 48T Back Connecti...

Page 152: ... voltage input via NPN transistor or switching of contact Operating modes A signal ON delay F accumulative operation selectable Reset system Power reset A signal ON delay mode only external manual resets Sensor waiting time 216 ms typ 250 ms max Control output is turned OFF and no input is accepted during sensor waiting time External power supply 50 mA at 12 VDC 10 Display 7 segment LEDs 12 mm hig...

Page 153: ...kV between power terminals 600 V between input terminals square wave noise by noise simulator pulse width 100 ns 1 s 1 ns rise Static immunity Destruction 15 kV Malfunction 8 kV Vibration resistance Destruction 10 to 55 Hz 0 75 mm single amplitude each in three directions Malfunction 10 to 55 Hz 0 5 mm single amplitude each in three directions Shock resistance Destruction 294 m s2 30G each in thre...

Page 154: ... OFF OFF 0 1 to 999 9 s OFF ON OFF 1 to 9999 s ON ON OFF 0 min 01 s to 99 min 59 s OFF OFF ON 0 1 to 999 9 min ON OFF ON 0 h 01 min to 99 h 59 min OFF ON ON 0 1 to 999 9 h Note Switches 1 to 6 are all set to OFF before shipping The same switch settings apply to AC and DC models ON 1 3 4 5 6 2 Top of Timer Timer Control with Power Start When using the H5CL with power start short circuit the start i...

Page 155: ... DIN43700 1 0 A 48n 2 5 Note 1 The mounting panel thickness should be 1 to 4 mm 2 It is possibletomounttimers sideby side but onlyinonedirection 3 WhentheTimers aremountedclosely sideby side the Timers will not be water resistive 44 7 x 44 7 58 51 48 99 2 7 5 51 48 58 7 5 Y92S 29 rubber packing provided Panel Y92F 30 flush mounting adaptor provided P3GA 11 back connecting socket sold separately Y9...

Page 156: ...utput Transistor output 6 7 8 9 10 5 4 3 2 Reset Start Gate Key protection External power supply 12 VDC 50 mA max 11 1 8 9 11 Transistor output Contact output 100 to 240 VAC Input common 0 V 6 1 Load Sensor Note Power supply circuit is insulated from the internal circuit or I O Input Circuits Start Reset and Gate Input H5CL Aj AC Models Key Protection Input IN Vin 3 5V 16V max 1 k Internal circuit...

Page 157: ...ating voltage 10 VDC Note When connecting a two wire sensor to a DC models sup ply 24 VDC 21 6 to 26 4 VDC to the timer Key Protection Input 4 3 10 6 AC models DC models Open collector or contact 0 V Key protection input Key Protection Input ON impedance 1 k max the leakage current is approx 1 mA when the impedance is 0 ON residual voltage 0 5 V max OFF impedance 100 k min Maximum applicable volta...

Page 158: ...s also recom mended to shield the input signal wiring to prevent electronic inter ference Organic solvents such as paint thinner as well as very acidic or basic solutions can damage the outer casing of the Timer Preset Value Change When changing preset value during timing operation output will turn ON if preset value is changed as follows Display mode UP Present value preset value Display mode DOW...

Page 159: ...nforms to EMC standards Six language instruction manual provided RC Ordering Information Functions 9 field selectable Contact type One SPDT relay and two NPN open collector transfor output Terminal form 18 terminal screws on rear of case Part number H5BR B Supply voltage AC 24 100 to 240 V 50 60 Hz DC 12 to 24 V Note Specify both the model and control power supply when ordering Model Legend H5BR T...

Page 160: ...es Elapsed time UP remaining time DOWN Output modes A A 1 A 2 A 3 b b 1 d E F Reset system Power reset except A 3 b 1 and F modes External manual automatic resets internal according to A 1 b b 1 d and E mode operation Batch counting function Yes Sensor power supply 12 VDC Input signals Start reset gate batch count reset key protect inputs Input method No voltage input Via opening and closing of co...

Page 161: ...ror including temperature and voltage effects Power start 0 01 0 05 s max Control signal start 0 005 0 03 s max rate for set value Insulation resistance 100 M min at 500 VDC between current carrying terminal and exposed non current carrying metal parts and between non continuous contacts Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying terminal and exposed non current carr...

Page 162: ...tches to the present value display Operation key 15 Batch key Switches to the batch display 16 Mode key Switches from run mode to setting mode Changes items in the setting mode 17 Reset key Resets timing and outputs Factory Settings The following table shows the timer settings when it is shipped Please change the settings as necessary to suit the system before operation Settings and the display re...

Page 163: ...ts are not accepted while reset input is ON Reset indicator lit while reset input is ON Gate Inhibits timer operation Batch count reset Resets batch count to zero and batch output turns OFF on leading edge Batch count signals are not accepted while batch count reset is ON Key protect Makes keys inoperative according to key protect level Key protected indicator lit while key protect input is ON Eff...

Page 164: ...Setting mode Press the DISPLAY key Press the BATCH key Press the DISPLAY key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Note 1 Set values are changed using the increment keys 1 to 4 2 The large arrows indicate the parameter displayed first when the mode is changed with the MODE or DISPLAY key ...

Page 165: ...Output time Determines the duration of the control output Will be displayed when the output mode is A A 1 A 2 A 3 b or b 1 Will not be displayed when the output mode is d E or F Use keys 1 to 3 to change the value Key1 adjusts the first digit 0 1 s digit Key2 adjusts the second digit 1 s digit Key3 adjusts the third digit 10 s digit Key4 selects either hold output or one shot output 0 1 2 8 9 hold...

Page 166: ...ue Nonsignificant zeros are normally not shown on the set value display Note Read Changing Set Values in the Precautions section pg 15 before changing the Timer set value during operation Changing the Batch Count Set Value 1 Press the BATCH key to switch from the present value display to the batch count display 2 Change the set value when the Timer is set to the batch count display Nonsignificant ...

Page 167: ...is enabled Settings changed in the setting mode are not effective until run mode is entered As the operating conditions will change in this case always reset operation with the RESET key or a reset input 2 Press the MODE key to scroll successively through the items that can be set 3 Changing the selected item Press the MODE key until the desired item appears Change the item setting by pressing key...

Page 168: ...r for a programmable one shot time period Output mode A 2 Power ON delay 1 Timer resets when power comes on t Power Start signal Gate Reset Control output Set value Timing diagram UP DOWN 0 0 Set value Timing begins when power is applied Start signals act as a gate input causing the present value to The control output will be energized when the present value equals the preset time The output can b...

Page 169: ...eated until a reset input is applied or power is interrupted Output mode b 1 Repeat cycle 2 Timer does not reset when power comes on Power Start signal Gate Reset Control output Set value Timing diagram UP DOWN 0 0 Set value The OFF ON cycle is initiated at the leading edge of the start signal The output relay will be OFF for the preset time then ON for the preset time The cycle will be repeated u...

Page 170: ...he output is sustained until power is interrupted or a reset signal applied Batch Counter Operation Batch count reset Batch output Batch count set value Batch count present value 0 The batch count output holds until reset by the batch count reset The present value of the batch count advances continuously 1 The batch count present value remains at 0 while the batch count reset is ON 2 When the batc...

Page 171: ...nless otherwise indicated Panel Mounting H5BR M3 5 terminal screw effective length 6 mm 7 panel thickness Panel Mounting Adaptor Panel Cutouts Panel cutouts are as shown at right according to DIN43700 Panel 72 72 6 100 67 6 100 6 100 min 82 min 68 0 7 0 68 0 7 0 ...

Page 172: ... the H5BR are no voltage short circuit or open inputs No voltage Input Signal Levels No contact input Contact input 1 High level Transistor ON Residual voltage 2 V max Impedence when ON 1 k max 2 Low level Transistor OFF Impedence when OFF 100 k min Use contacts which can adequate ly switch 2 mA at 5 V No contact Input NPN Transistor Contact Input No contact Input Sensor Timer High transistor ON T...

Page 173: ...nction The following displays will appear if an error occurs The present value and output enter the same status as after pressing the RESET key Display Error Output status Correction Setting e1 CPU OFF Press RESET key No change e2 Memory batch count to 0 Set at the factory Changing Set Values The Timer set value can be changed while the timer is operating so a high value can be set temporarily to ...

Page 174: ...table Contact type SPDT relay Solid state open collector Unit Depth Basic 78 mm Standard 100 mm Short body 64 mm Basic 78 mm Standard 100 mm Short body 64 mm Display Backlit H5CR B H5CR S H5CR BS H5CR SS Non backlit H5CR L H5CR LS Supply voltages AC 24 100 to 240 V 50 60 Hz 24 100 to 240 V 50 60 Hz 24 100 to 240 V 50 60 Hz 24 100 to 240 V 50 60 Hz DC 12 to 24 V 12 to 24 V 12 to 24 V 12 to 24 V Not...

Page 175: ...Immunity Conducted Disturbance ENV50141 10 V 0 15 to 80 MHz level 3 Immunity Burst IEC801 4 2 kV power line level 3 2 kV I O signal line level 4 Approvals UL File no E41515 CSA File no LR22310 Conforms to EN50081 2 prEN50082 2 Display modes Elapsed time UP remaining time DOWN Output modes A A 1 A 2 A 3 b b 1 d E F Reset system Power reset except A 3 b 1 and F modes External manual automatic resets...

Page 176: ... Characteristics Repeat accuracy including temperature and voltage effects Power start 0 01 0 05 s max Control signal start 0 005 0 03 s max rate for set value Insulation resistance 100 M min at 500 VDC between current carrying terminal and exposed non current carrying metal parts and between non continuous contacts Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying terminal...

Page 177: ...ey Switches from run mode to set mode Changes items in the set mode 14 Reset key Resets timing and outputs 2 3 4 5 10 12 13 14 9 1 7 11 6 8 Factory Settings The following table shows the timer settings when it is shipped Please change the settings as necessary to suit the system before operation Settings and the display receive power from the internal battery and are therefore unaffected by extern...

Page 178: ...ons Inputs Start signal Stops timing in A 2 and A 3 power on delay modes Starts timing in other modes Reset Resets present value to zero in UP modes to preset in DOWN mode Count inputs are not accepted while reset input is ON Reset indicator lit while reset input is ON Gate Inhibits timer operation Key protect Makes keys inoperative according to key protect level Key protected indicator lit while ...

Page 179: ...Input signal time Output time Output mode UP DOWN mode Setting mode Press the DISPLAY key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Press the MODE key Note 1 Set values are changed using the increment keys 1 to 4 2 The large arrows indicate the parameter displayed first when the mode is changed with the MODE or DISPLAY key 3 T...

Page 180: ...l output Will be displayed when the output mode is A A 1 A 2 A 3 b or b 1 Will not be displayed when the output mode is d E or F Change the output time with the increment keys 1 to 4 0 1 s 1s 0 5 s 5s 10 s 15 s 20 s hold Input signal time Changes the duration of the control and reset input signals Change the duration with the increment keys 1 to 4 1 ms 20 ms 1 20 Key protect level Locks certain ke...

Page 181: ...ation Setting Mode Changing Settings in the Set Mode 1 Press the MODE key to switch from run mode to set mode The Timer will continue operation if switched from run mode to set mode during operation The MODE key will be locked if the key protection function is enabled Settings changed in the set mode are not effective until run mode is entered As the operating conditions will change in this case a...

Page 182: ...wer interrupted or for a programmable one shot time period Output mode A 2 Power ON delay 1 Timer resets when power comes on t Power Start signal Gate Reset Control output Set value Timing diagram UP DOWN 0 0 Set value Timing begins when power is applied Start signals act as a gate input causing the present value to The control output will be energized when the present value equals the preset time...

Page 183: ...l a reset input is applied or power is interrupted Output mode b 1 Repeat cycle 2 Timer does not reset when power comes on Power Start signal Gate Reset Control output Set value Timing diagram UP DOWN 0 0 Set value The OFF ON cycle is initiated at the leading edge of the start signal The output relay will be OFF for the preset time then ON for the preset time The cycle will be repeated until a res...

Page 184: ... Gate Reset Control output Set value Timing diagram UP DOWN 0 0 Set value Timing begins on the leading edge of the start signal The control output is only energized during timing The timer is reset when power is interrupted or a reset signal is applied Output mode F Cumulative Timer does not reset when power comes on Power Start signal Gate Reset Control output Set value Timing diagram UP DOWN 0 0...

Page 185: ... unless otherwise indicated H5CR L Panel Mounting Surface Mounting M3 5 terminal screw effective length 6 mm H5CR B Panel Mounting H5CR S Panel Mounting M3 5 terminal screw effective length 6 mm 48 48 84 0 63 7 6 0 7 14 3 44 8 48 48 100 6 44 8 48 48 6 64 44 8 ...

Page 186: ...pter Panel Y92F 30 Panel mounting adapter Panel Note 1 The mounting panel thickness should be 1 to 4 mm 2 It is possible to mount timers side by side but only horizontally 48 58 6 85 9 92 8 H5CR L P2CF 08 58 48 6 100 58 48 6 64 60 min 60 min A 45 0 6 0 45 0 6 0 0 6 0 A n x 45 n 1 x 3 5 Panel Y92F 30 Panel mounting adapter P3G 08 Rear surface connection socket 44 8 44 8 ...

Page 187: ...rotect input OUT 100 to 240 VAC 24 VAC Unused Unused Start signal input Transistor output 12 to 24 VDC 11 6 7 8 9 10 1 2 3 4 5 12 Input use 0 V Reset input Gate input Key protect input OUT Unused Unused Start signal input Note Do not connect unused terminals Connections The inputs of the H5CR are no voltage short circuit or open inputs No voltage Input Signal Levels No contact input Contact input ...

Page 188: ...lay Error Output status Correction Set e1 CPU OFF Press RESET key No change e2 Memory Set at the factory Changing Set Values The Timer set value can be changed while the timer is operating so a high value can be set temporarily to inactivate the timer or a low value can be set to activate the timer more quickly If the set value is changed accidentally during operation the timer might be activated ...

Page 189: ...modes N F C R K P and Q are available RC Ordering Information Operation system Resetting system No of digits Backup power supply function for memory protection Model Time limit operation integrating operation Power OFF resetting excluding M 4 digits switch selectable 0 01 to 99 99 s 0 1 to 999 9 s 1 to Not provided H5AN 4D integrating operation excluding M external resetting manual resetting autom...

Page 190: ...art see note Setting error Influence of voltage Influence of temperature Insulation resistance 100 M min at 500 VDC between current carrying terminal and exposed non current carrying metal parts between non continuous contacts Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying and non current carrying metal parts 750 VAC 50 60 Hz for 1 min between non continuous contacts Vib...

Page 191: ...an be switched if L R is 7 ms In both cases a life of 100 000 operations can be expected The minimum applicable load is 10 mA at 5 VDC P reference value Nomenclature 7 segment LED display Front cover Time up indicator Rated time label affixing section when a rated time label of 99 min 59 s is affixed Reset input indicator Pushbutton switch for manual reset Internal unit fixing screw One shot time ...

Page 192: ...crement up to 9999 even after reaching the set value and then returns to all zeroes In DOWN mode the digital display continues to up 9999 and then decrements 9998 9997 after reaching all zeroes The control output is held until a reset input is applied C The digital display returns to the initial setting once the set time has elapsed and the timer restarts the timing operation When the set time has...

Page 193: ...e shot time The timer repeats this cycle Q In UP mode the digital display continues to increment after reaching the set value during the one shot time In DOWN mode the digital display continues to 9999 and then decrements 9998 9997 after reaching all zeros during the one shot time However in both UP and DOWN modes the digital display returns to the initial setting after the one shot time and the t...

Page 194: ...d time operation mode and output level of the solid state output when the set time has elapsed etc Set these switches for programming the desired functional specifi cations by referring to Positions and Functions of Specification Se lector Switches Open the front cover The internal unit comes out by loosening the internal unit fixing screw ...

Page 195: ... hrs 0 1 to 999 9 hrs 7 9999 hrs 1 to 9999 hrs 8 99 99 s Same as switch position 0 9 999 9 s Same as switch position 1 Note Select the appropriate label from the ratedtime labels sup plied as accessories and affix it on the proper position on the front panel SW2 Switch position Operating mode Display mode 0 N DOWN display 1 F 2 C 3 R 4 K 5 P Note 1 Same as it h 6 Q switch position 0 7 N see note 1...

Page 196: ...Leave them open Unused Connections Power Supply Connection Connect the required supply voltage to terminals 1 and 2 AC Power Supply DC Power Supply Load Connection Terminals 4 5 and 6 are for contact output while terminals 12 and 13areforsolid stateoutput Terminal 14is connectedtoabsorbthe surge if an inductive load is connected The control outputs of both contact type and solid state type are si ...

Page 197: ...s as shown below the voltage of the solid state circuit V should be 13 to 30 V and the VCE S of the transis tor should be less than 3 V the current that flows from either termi nal 9or10is approximately 10mA Moreover it is essential that the circuit be ON for gate or reset input and OFF when thereis noinput Connection of a Power Supply for Externally Connected Components TheH5ANhasabuilt inpowersu...

Page 198: ...ntion not to alter the set value to this state 3 Since the sexagesimal system is adopted when a rated time of 99 min 59 s or 99 hrs 59 min is selected any value set to 6 or more i e 6 9 in the order of x 10 s or x 10 min respectively will be rated as 5 Some erroneous setting examples are shown below Examples of Setting Actual Operating Time 4 Whenchangingtheset time whilepower is being supplied an...

Page 199: ...very C Power failure of 0 01 to 0 5 s Note Either A or B The type with a backup power supply function for memory protec tion restarts in the status preceding the power failure as shown in A regardless of the duration of the power failure 7 The type with backup power supply for memory protection incorporates a battery for backup power supply which lasts for about ten years of normal use meaning dat...

Page 200: ...bel WARNING Fire Explosion and Severe Burn Hazard The H5AN has a built in lithium battery Be sure to dispose of theoldH5ANproperly as lithium batteries arelikely toexplode if incinerated ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L50 E1 7 ...

Page 201: ...dicator Not provided with IN and UP indicators Provided without UP indicator indicators UP display timer increments from 0 to the set time DOWN display timer decrements from the set time to 0 indicators Provided UP display timer Backup power supply function for memory protection Not provided Not provided Provided Not provided Not provided Not provided Rated ti 0 001 to 9 999 s H5CN ZNS H5CN XZNS a...

Page 202: ...rminal and exposed non current carrying metal parts between power supply circuit and control output circuit Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying terminal and exposed non current carrying metal parts between power supply circuit and control output circuit Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 ...

Page 203: ... In both cases a life of 100 000 operations can be expected The minimum applicable load is 10 mA at 5 VDC P reference value Operation Timing Chart Digital Display UP Display DOWN Display Note For the models without digital display an IN indicator LED is provided to indicate power application This LED however goes off when the reset input is applied Dimensions Note All units are in millimeters unle...

Page 204: ...ting Holes Mounting Height of Timer with Socket P2CF 08 P2CF 11 Terminal Arrangement Top View Mounting Holes Mounting Height of Timer with Socket Two 4 5 dia holes Two 4 5 dia holes or M4 Eight M3 5 x 7 5 sems screw Note Track mounting is also possible Back Connecting Socket P3G 08 Terminal Arrangement Bottom View Mounting Depth of Timer with Socket 116 9 95 1 10 9 ...

Page 205: ...tically 3 No cover N 48n 2 5 1 0 With hard cover N 48n 2 5 n 1 x 3 1 0 Spacer PFP S Gang mounting of more than 2 units horizontally 27 dia Eleven M3 5 sems 10 9 N Protective Cover The protective cover shields the front panel particularly the count value setting section from dust dirt and water drip as well as prevents malfunctioning of the timer due to static electricity Y92A 48D see note 1 Soft c...

Page 206: ...t thetimersothat therequiredsupply voltagecanbeapplied across terminals B and J Connection of Load Circuit Control Output Model With Backup Power for Memory Protection Contact Output Type H5CN jN Terminals E F and H are for contact output contacts Load 1 con nected inseries withNO contact between terminals F andH is nor mallyopen andtheloadcircuitvoltagewillbeappliedafterthelapse of the set time T...

Page 207: ...the transistor turns ON Use of a high reliability gold plated contact is recommended for the reset input For the reset in put transistor select the one satisfying the following electrical rat ings VCEO 20 V min IC 50 mA min ICBO 0 5 A max Reset input contact Timer resets when contact is made Reset input transistor Timer resets when transis tor is ON Model With Backup Power for Memory Protection Co...

Page 208: ...ection Battery Connection Connect the Y92S 20 backup battery between terminals A and D paying attention to the polarities Battery Connections When Recording Interrup tions AlwaysconnectabatterywhenusingUnits withapowerinterruption recording function Any 3 V battery may be used but the time the interruptionis recordedforwilldependonthecapacityof thebattery When using the Unit for the first time aft...

Page 209: ...Integrating Operation Use of the gate input terminal permits the timer to sum up timers T1 T2 and T3 i e integrating operation as shown below UP Display Timer DOWN Display Timer Operating Time Measurement The UP display timers with digital display can be used to measure the operating time of other timers or equipment For this measure ment set the set time to the maximum Note The digital display of...

Page 210: ...put When changing the set time during normal operation pay special attention not to alter the set value to this state 3 Whenchangingtheset time whilepower is being supplied an inadequate push of the thumbwheel switches will display two numbers in one digital display window causing the operating time to drift widely Therefore press the thumb wheel switches surely Take particular care in the case wh...

Page 211: ...e mounting track mounting Flush mounting Time limit operation self resetting Separate motor and clutch i 8 pin round socket SPDT SPDT H2C 8 H2C 8 with Y92F 30 adapter se esett g a d c utc connection 11 pin round socket H2C H2C with Y92F 30 adapter Front screw H2C F Time limit operation electric resetting 8 pin round socket SPDT H2C 8R H2C 8R with Y92F 30 adapter e ect c esett g 11 pin round socket...

Page 212: ...os 1 Refer to Engineering Data since theelectrical servicelife of the built in switch will change in such a case Characteristics Accuracy of operating time 0 5 max 1 max at 0 2 to 6 s for the time range code B or at 0 5 to 12 s for the time range code C Setting error 2 max Reset time 0 5 s max Influence of voltage 1 max Influence of temperature 2 max Insulation resistance 100 M min at 500 VDC Diel...

Page 213: ...iming Chart H2C 8 ON delay 8 pin Round Socket H2C F H2C F R Rt Resetting time H2C 8R OFF delay 8 pin Round Socket Rt Resetting time Note For the types rated at 24 and 48 VAC the timing operation indicator is not equipped Set time Rt Set time Rt Set time T Rt Rt Power failure time t Rt T t Rt Set time Set time Rt Rt Resetting time see note Rt Resetting time see note Rt Set time T Rt Rt T t Power fa...

Page 214: ...nterval of 5 mm between timers For a load current of 6 A max dimension L becomes 20 mm min with an interval of 10 mm between timers Two M4 or 4 5 dia holes 44 8 x 44 8 Accessories Order Separately Track Mounted Front Connecting Socket P2CF 08 Two 4 5 dia holes Two 4 5 dia or Two M4 Eight M3 5 x 7 5 sem Mounting Holes Terminal Arrangement Top View Mounting Height of Timer with Socket PF085A Mountin...

Page 215: ...s Eleven M3 5 7 sems P3GA 11 Terminal Arrangement Bottom View Terminal Arrangement Bottom View Mounting Height of Timer with Socket P3G 08 Mounting Holes Terminal Arrangement Bottom View Mounting Height of Timer with Socket PL11 Solder Terminals Approx 20 5 Two 3 5 dia or M3 socket mounting holes Two 2 dia holes 35 max Back Connecting Socket PL08 Solder Terminals Two 2 dia holes Mounting Holes Ter...

Page 216: ...timer housing since the adapter security notches are provided on all four sides of the housing H2C with PF113A H2C F Note For a load current of 3 A max a spacer and an end plate are not required For a load current of 6 A one spacer or an end plate is required Note For a load current of 1 A max a spacer and an end plate are not required For a load current of 3 A max one spacer or an end plate is re...

Page 217: ...connectable per timer Protective Cover Y92A 48B The protective cover shields the front panel particular ly the time setting section from dust dirt and water as well as prevents the set value from being altered due to accidental contact with the time setting knob Installation Terminal Arrangement H2C 8 ON delay 8 pin Round Socket H2C F H2C F R H2C 8R OFF delay 8 pin Round Socket ...

Page 218: ... C Electrical Set The motor and clutch do not need to be reset simultaneously Use the voltage applied to the clutch for resetting with the H2C R Do not allow power to be continuously applied to the motor and clutch for extended periods of time Others Do not turn the operation time setting knob beyond the range of the scale Toachievehigher accuracy in setting measure theoperation time while turning...

Page 219: ...e 1 Specify both the model number and supply voltage when ordering 2 Surface mounting models can be used as a flush mounting type by attaching an exclusive adapter Y92F 40 to the timer Specifications Time Ranges Rated time Time setting range Time division 50 Hz 60 Hz 5 s 0 2 to 6 s 0 2 to 5 s 0 2 s 10 s 0 5 to 12 s 0 5 to 10 s 0 5 s 30 s 1 to 36 s 1 to 30 s 1 0 s 60 s 2 to 72 s 2 to 60 s 2 0 s 3 m...

Page 220: ...2 000 VAC 50 60 Hz for 1 min between current carrying and non current carrying parts between contact and control circuit and between contacts of different polarities 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 16 7 Hz with 4 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G ...

Page 221: ... millimeters unless otherwise indicated H2A H2A H Note F shaped hook PHC 1 for PF085A and L shaped hook PHc 4 for PL08 are supplied with the timer H2A H with Adapter Panel Cutouts Note Back connecting socket US08 and Y shaped hook PHC 3 are supplied with the timers Panel Y92F 40 adapter for flush mounting See note ...

Page 222: ...l Cutouts Note PF085A can be used as a front connectingsocket Back Connecting Socket PL08 Solder Terminals Mounting Holes Terminal Arrangement Bottom View Mounting Height of Timer with Socket Mounting Track Meets DIN EN50022 PFP 100N PFP 50N see note Note This dimension applied to PFP 50N End Plate PFP M PFP S Two 4 5 dia holes Eight M3 5 7 sems Two 4 5 dia or M4 holes Top View Two 2 dia holes Bot...

Page 223: ...the set time has elapsed be sure to limit the carry current to less than 1 A When using the timers at an ambient temperature of more than 40 C be sure to reset the timers immediately after the set time has elapsed Wiring When wiring employ a multi core cable having a finished outer di ameter of less than 10 5 mm or insulated twisted wires with less than a 3 mm outer diameter ALL DIMENSIONS SHOWN A...

Page 224: ...ing see note 4 Flush mounting Surface mounting see note 4 Flush mounting Time limit operation self resetting Parallel motor and clutch SPDT SPST NO see note 3 STP N STP Y STP NM STP YM clutch connection SPST NO STP NH STP YMH SPDT STP ND Separate motor and SPST NO see note 3 STP N2 Time limit operation electric resetting motor and clutch connection see note 3 STP NR STP NMR STP YMR Note 1 Specify ...

Page 225: ...istive load Instantaneous contact 1 5 A at 250 VAC resistive load Note The front panel of the timer is color coded to identify the following supply voltage classifications 100 to 120 V Blue 220 to 240 V Red Other classes Black Characteristics Accuracy of operating time 0 5 max 1 max for the 5 s and 10 s model Setting error 5 max Reset time 0 5 s max Influence of voltage 1 max Influence of temperat...

Page 226: ...Engineering Data Switching operations x 10 3 Load current A Operation Timing Chart STP N STP NM STP Y STP YM STP NH STP ND STP N2 STP NR STP NMR STP YMR When setting the time apply voltage across terminals 1 and 4 ...

Page 227: ... NM series timers Note US08 connecting socket is supplied with the timer Two 4 5 dia holes See note Two 4 5 dia timer mounting holes See note 1 75 See note 2 See note 2 Dimension L1 L2 L3 L4 STP N STP N2 63 5 84 92 5 61 STP ND STP NH STP NR STP NM STP NMR 74 1 94 6 103 1 60 2 STP Nj STP NMj with Adapter Note The mounting panel thickness should be 1 to 3 2 mm STP Yj STP YMj Dimension L1 L2 L3 STP Y...

Page 228: ...ecting Socket PL08 Mounting Holes Terminal Arrangement Bottom View Mounting Height of Timer with Socket Mounting Track Meets DIN EN50022 PFP 100N PFP 50N see note Note This dimension applied to PFP 50N End Plate PFP M Eight M3 5 7 sems Two 4 5 dia hoes Two M4 or Two 4 5 dia holes Top View Note 8PFA can be used as a front connecting socket Two 3 5 dia or M3 timer mounting holes Two 3 5 dia or M3 so...

Page 229: ...ly for resetting Do not apply power continuously for both the motor and clutch power supplies for extended periods of time Connecting Instantaneous Contact Circuit Socket terminals 1 and 3 are for an instantaneous contact circuit and are normally open Terminal 1 is internally connected to termi nal 2 to connect power The same phase must be used for both ter minal 2andforterminals 1and3 Thecontroll...

Page 230: ...to be mounted in line provide a dis tance of more than 5 mm between the two adjacent timers ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L03 E1 9 ...

Page 231: ...iming chart displayed for at a glance confirma tion DIN sized 48 x 48 mm RC Ordering Information Wiring Mounting method Model Screw terminals Flush mounting H5F B Surface mounting H5F FB Surface mounting track mounting H5F KB Specifications Ratings Rated supply voltage 100 to 240 VAC 50 60 Hz Operating voltage range 85 to 110 of rated supply voltage Power consumption Approx 2 VA Control outputs Co...

Page 232: ...iation due to voltage change and variation due to temperature change is 0 01 0 05 s max 0 01 also indicates an error in the time interval of a set time 2 The total time when power is not being supplied Operation Operation method Digital quartz Operation 1 Daily operation Multiple day operation possible 2 Pulse output operation pulse width can be set in units of 1 s from 1 to 59 s and in units of 1...

Page 233: ...utput regardless of the setting OUT Turns on the output according to the setting OFF Turns off the output regardless of the setting I TMR Timer pulse output Key P Selects timer operation or pulse operation Display Time Adjustment Mode Indicator Displays the Present Time Operation Time and Time Width Output Circuit Indicator Pulse Operation Indicator Present Date Date of Operation Indicator Partial...

Page 234: ...lse operation with the TMR Key Set the operation time with the Select Key h Key m WD Key and Write Key P P Operation data setting mode Press the Mode Key Set the non operation day and specific day with the d Key and Write Key Run mode Press the Mode Key Execute the timer operation according to the set time AUTO The time and date setting procedures in various operation modes are illustrated with di...

Page 235: ...Ordinary Timer Operation Example ON at 8 30 a m and OFF at 5 15 p m each day from Monday to Friday First set the Operation time setting mode with the Mode Key Display and key operation shaded portion indicates blinking of the indicator 5 Press the Mode Key to set the Operation day setting mode 6 Set Sunday and Satur day as non operation days with the d and Write Keys Initial screen 7 Press the Mod...

Page 236: ... above press the Write Key several times until appears P P Pulse Output Operation Example To turn on the output for 30s at 8 25 a m from Monday to Friday First set the Operation time set ting mode with the Mode Key Display and key operation shaded portion indicates blinking of the indicator 5 Use the d Key and Write Key to specify Sunday and Saturday as non operation days 6 Press the Mode Key The ...

Page 237: ...ight the special day op eration S indicator see note 2 Set the ON time to 8 30 a m with the h and m WD keys 3 Press the h and m WD Keys to set the OFF time to 0 30 p m Note 1 If the display is for the pulse operation change the operation mode to the timer operation with the TMR Key 2 Even in the pulse operation a specified day may be specified by displaying the special day indicator with the Selec...

Page 238: ...ng H5F FB Surface Mounting Mounting Dimensions Flush Mounting H5F B Panel Cutout Mounting Note To provided the dimension marked tight en the screw using the cut off marked H5F KB Surface Track Mounting Surface Mounting Mounting Hole 44 8 Protective cover Y92A 48 option 75 7 49 58 Protective cover option ...

Page 239: ...e 1 With mounting tracks PFP 100N or PFP 50N 2 With mounting track PFP 100N2 Mounting Track Meets DIN EN50022 PFP 100N PFP 50N PFP 100N2 Note This dimension applied to PFP 50N See note Twelve 25 4 5 elliptic holes Installation Connections Flush Mounting H5F B H5F FB Surface Track Mounting H5F KB ...

Page 240: ...y output After data has been set note that pressing the TMR P key to change the operation between the timer and pulse operation will cause the set data to be lost If a power failure occurs the output is turned off and the indicators go off during the power failure WARNING The H5F has a built in lithium battery When disposing of an entire timer containing a lithium battery be sure to do so prop erl...

Page 241: ...ntly Supply voltage from 100 to 240 VAC Surface flush or track mounting possible RC Ordering Information Wiring Mounting style Model Screw terminals Flush mounting H5S B Surface mounting track mounting H5S FB Specifications Time Ranges Rated time Time setting range Time division 1 week 00 00 a m to 11 59 p m 1 min Ratings Rated supply voltage 100 to 240 VAC 50 60 Hz 24 VDC Operating voltage range ...

Page 242: ...ductive load cos 0 7 50 000 operations min 100 W at 100 VAC lamp load 10 000 operations min 300 W at 100 VAC lamp load Approved standards UL File No E52800 CSA File No LR22310 10 A at 250 VAC general use 15 A at 125 VAC resistive load Weight Approx 200 g Note The total error including the repeat accuracy settingerror variationdue tovoltage change and variationdue totemperature changeis 0 01 0 05 s...

Page 243: ...Key Operations No Function 1 Shifts the cursor B specifying a day to the right 2 Sets or cancels a specified day 3 4 Sets a time or ON OFF time width 5 Monitors the parameters set for an operation during an operation 6 Sets parameters 7 Sets a time adjustment mode 8 Specifies a cyclic operation or sets a pulse width 9 Specifies a day substitution operation 10 Cancels the parameters set for each ci...

Page 244: ...ation is automatically started on power recovery MANUAL Operation is started by applying an external signal after power recovery Day override operation Executes a day s operation on another day The specified new operation is performed only for one week Programming Before setting the parameters necessary for each operation the operation of circuits outputs 1 and 2 must be determined Also whether th...

Page 245: ...day Display and key operation Shaded portion indicates blinking of the indicator 1 Move the cursor B with the Shift Key Press the Set Key so that of a desired day turns on Select Monday through Friday Display and key operation Shaded portion indicates blinking of the indicator 4 Set the time to 5 45 p m with the h and m Keys Press the Write Key 2 Set the time to 9 00 a m with the h and m Keys 5 Th...

Page 246: ...to the initial screen 1 s lat er The Mode Switch to RUN Initial screen Multiple day Operation Set the Mode Switch to P1 or P2 Example ON at 9 00 p m Monday and OFF at 3 15 a m Tuesday Display and key operation Shaded portion indicates blinking of the indicator 1 Specify Monday with the Shift and Set Keys Display and key operation Shaded portion indicates blinking of the indicator 4 Set the time to...

Page 247: ... Wednesday Display and key operation Shaded portion indicates blinking of the indicator 1 Press the Check Key To check the operation of a day other than today Example To check Monday s opera tion on Wednes day Display and key operation Shaded portion indicates blinking of the indicator 1 Move the cursor to the Monday position using the Shift and Set Keys 2 The first item of today s operation set f...

Page 248: ...dicates blinking of the indicator 1 Set the Mode Switch to the position of the circuit whose setting is to be canceled 2 Press the CLR Key To cancel the day override program Display and key operation Shaded portion indicates blinking of the indicator 1 Set the Mode Key to RUN Depress the Copy Key for at least 1 s 2 Press the Clr Key The display returns to the initial screen 3 The message Clr is di...

Page 249: ...nel thickness 1 to 5 mm When mounting the time switch on a soft iron panel using the M4 tapping screws the diameter of the mounting holes drilled into the panel vary according to the panel thickness as follows If the panel is die cast aluminum the hole diameter should be slightly larger Panel thickness 0 8 1 0 1 2 1 6 2 0 2 6 3 2 4 0 Hole diameter 3 6 3 7 Accessories Order Separately Y92A 72C Prot...

Page 250: ...DIN EN 50022 This dimension applies to the PFP 50N Mounting Track Installation Terminal Arrangement H5S B Flush Mounting Models Rear View H5S FB Surface Mounting Models Front View Note The terminal screws are M3 5 Connections H5S B Flush Mounting Models H5S FB Surface Mounting Models Power source Power source ...

Page 251: ...sible no operation is performed If the Mode Switch is set to the P1 or P2 position no output is pro duced Therefore after setting has been done set the Mode Switch totheRUNpositionandconfirm that theautomatic operationindica tor lights Theset datamay beerased if the OUT switch is moved betweenthe TIMER and PULSE positions after the data has been set WARNING The H5S has a built in lithium battery W...

Page 252: ...ion possible Surface flush or track mounting RC Ordering Information Wiring Backup power supply function for memory protection No of program steps Model Screw terminals Provided approx 10 years at 25 C 16 in total of first and second circuits Each ON or OFF is considered to be one step H5L A Specifications Time Ranges Rated time Time setting range Time division 24 hrs x 7 days 00 00 to 23 59 1 min...

Page 253: ...Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 300 m s2 approx 30G Malfunction 100 m s2 approx 10G Ambient temperature Operating 10 C to 55 C Ambient humidity Operating 35 to 85 Life expectancy 100 000 operations min 15 A at 250 VAC resistive load Approved standards UL File No E52800 CSA File No LR22310 SEV Weight Approx 350 g Note Theoverallerror whichincludes r...

Page 254: ... is held down the displayed digit increments continuously when the Minus Key is held down it decrements continuously Minus Key is held down it decrements continuously When specifying output The Plus Key specifies output ON while the Minus Key specifies output OFF Note that if the same key is pressed twice the output specification becomes invalid neither ON nor OFF is set Cycle Key Specifies the cy...

Page 255: ...he current time and output status are displayed but the op eration mode is not displayed After starting the H5L the colon between the hour and minute blinks to indicate that time count is in execution Note The H5L operates in accordance with the program already set even while another program is being set The output status dis play etc during programming displays the setting be ing programmed There...

Page 256: ...rent time 10 11 First circuit OFF Second circuit ON Second operation time setting The second circuit turns ON Sunday to Thursday operation by the set program is executed It turns OFF on Friday and Saturday operation by the set program stops Current time setting Current day of week Tuesday Current time 9 31 Second Weekday setting The second circuit turns ON Sunday to Thursday operation by the set p...

Page 257: ...igits shown in are blinking 1 Setting Current Time To set the current time day of the week hour and minute must be specified First turn on the power to the H5L The contents of the memory are cleared on power up and the TIM ADJ indicator is displayed as shown on the left As an example set the time to 11 15 on Tuesday Start by setting the day of the week The blinking indicator indicates the paramete...

Page 258: ...output to the OFF state using the Minus Key and store it in memory by pressing the Write Key The display returns to the initial state and waits for the next program command to be input Now let us turn to the setting of the day of the week 3 Fist Circuit Day of the week Setting By pressing the Mode Key place the H5L into DAY SET mode The display will be as shown on the left Press the Plus Key to op...

Page 259: ...this example Set the hour to 20 using the Plus or Minus Keys then press the Write Key Set the minutes to 30 and press the Write Key again The programming of the cyclic operation is now complete The timer will wait for input of a new program as shown We will now have to set the day of the week for the second circuit 5 Second Circuit Day of the Week Setting Press the Mode Key to place the H5L into P...

Page 260: ...mensions Note All units are in millimeters unless otherwise indicated H5L A Mounting Dimensions Flush Mounting Use a U shaped mounting bracket to flush mount the unit Panel Cutout Dimensions Mounting Bracket Included ...

Page 261: ...Mounting Bracket Included Two M4 taps Mounting bracket Panel Track Mounting Hook the upper part on the rear surface to the upper edge of the mounting track and press the unit down Dimensions 59 8 See note 1 68 5 See note 2 Note 1 When using mounting track PFP 100N or PFP 50N 2 When using mounting track PFP 100N2 ...

Page 262: ...See note 2 See note See note Note 1 This dimension is 15 mm on both ends in the case of the PFP 100N but on one end in the case of the PFP 50N 2 The length l of each mountingtrack is shown in this table 3 A total of twelve 25 x 4 5 elliptic holes are provided with six holes cut from each end of the track at a pitch of 10 mm between holes PFP 100N 1 m PFP 50N 50 cm PFP 100N2 1 m ...

Page 263: ...de of the front 2 Slide the upper part of the unit approx 15 mm upward 3 After the terminals appear perform wiring 4 Return the upper part of the unit to the original position and tighten the screw Connections Connect the power supply between terminals A and B the load for the first circuit between terminals G and H and the load for the se cond circuit between terminals E and F Terminals C and D a...

Page 264: ...tions Corrosive gases Constant vibrations or large shocks Water or oil spray Dust Direct sunlight Organic solvents thinner or benzine strong acids or bases If operating conditions exceed the above values besure toconnect a surge absorber When switching inductive loads counterelectro motive force is generated When using the H5L as a switch contac tor or for similar functions connect asurge absorber...

Page 265: ...H2F WMF SPDT H2F DFC H2F DMFC H2F WMFC Accessories Order Separately Extra programming tabs 1 pair for each ON OFF Y92S 21 Note 24 hour type is supplied with three pairs of programming tabs 1 week type is supplied with seven pairs of programming tabs Specifications Time Ranges Operation period Minimum division Minimum set time Maximum set time 24 hour 15 min 15 min 23 hrs 45 min 1 week 1 hr 2 hrs 1...

Page 266: ...function 10 to 55 Hz 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 200 m s2 approx 20G Ambient temperature Operating 10 C to 55 C Ambient humidity Operating 35 to 85 Life expectancy 2 years min approx 10 000 operations min Approved standards UL File No E52800 CSA File No LR22310 Weight Flush mounting approx 150 g Surface mounting approx 200 g Note 1 Accura...

Page 267: ...H2F D DM WM DC DMC WMC Panel Cutout Recommended panel thickness 3 2 mm Note The mounting adapter and screws are included 65 5 Installation Connections Synchronous Motor Model SPST NO Output H2F D SPDT Output H2F DC H2F DF H2F DFC ...

Page 268: ...ries 3 If the lead wires have been connected to the timer from the front of the panel before the timer is mounted in the panel engage the timer to part A of the adapter and push it in the direction of B Then tighten the two screws as described in 2 Panel Lead wire B A Time Setting To set the time turn the center knob clockwise to the correct time Turning it counterclockwise or turning it with your...

Page 269: ...s 5 and 6 are turned OFF Whenitis settotheAUTOposition theoutputis turnedONandOFF according to the setting of the programming tabs Whenthemanual switchis set totheONposition load1 connected across terminals 4 and 5 is turnedON andload 2 across 5and 6 is turned OFF Output Indicator The output indicator at the upper left corner of the front panel shows the status of the output when the manual switch...

Page 270: ... number and supply voltage when ordering All H2E series Timers are supplied with two pairs of setting pins one pair for each ON operation and OFF operation as the standard accessories If more setting pins are required also specify the required number of setting pins 2 For the flush mounting types a mounting bracket is supplied 3 Repetitive operations can be performed in a cycle of 24 hrs Specifica...

Page 271: ... 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 200 m s2 approx 20G Ambient temperature Operating 10 C to 55 C Ambient humidity Operating 45 to 85 Life expectancy 2 years min 10 000 contact operations min Weight H2E Y approx 315 g H2E Y 2 approx 360 g Dimensions Note All units are in millimeters unless otherwise indicated H2E Four 8 dia holes for tightening s...

Page 272: ...ee note Panel Mounting bracket 1R max 102 0 4 Note The mounting panel thickness should be 1 to 3 2 mm 74 0 4 8 8 8 10 87 0 5 120 117 0 5 90 106 Installation Connections H2E H2E Y H2E 2 H2E Y2 100 110 200 220 VAC ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L10 E1 8 ...

Page 273: ...hod No of control outputs Mounting method Model Continuous repetition 8 Surface mounting H5RA 8 16 H5RA 16 Specifications Time Ranges Rated time Setting range Cycle Output 9 99 s 0 02 to 9 99 s 0 00 to 9 98 s see note 99 9 s 0 2 to 99 9 s 0 0 to 99 8 s see note 999 s 2 to 999 s 0 to 998 s see note 99 9 min 0 2 to 99 9 min 0 0 to 99 8 min see note 999 min 2 to 999 min 0 to 998 min see note 99 9 hrs...

Page 274: ...0 ms Memory protection With built in battery 10 years at 25 C Power ON time 0 5 s max Insulation resistance 100 M min at 500 VDC between current carrying and non current carrying parts and between power circuit and control circuit Dielectric strength 1 500 VAC 50 60 Hz for 1 min between current carrying and non current carrying parts and between power circuit and control circuit Vibration resistan...

Page 275: ...ate command parameter F PV Present Value Indicator Illuminates while a present time value is being displayed on the time value display G SV Set Value Indicator Illuminates while a set time value is being displayed on the time value display H ON Indicator Illuminates to indicate that the ON time is being set I OFF Indicator Illuminates to indicate that the OFF time is being set J MULTI Indicator Il...

Page 276: ...signal is input OUTPUT MODE When this input signal is turned ON the control outputs remain OFF until either the START signals or the RESET signal is input When it is OFF the control output returns to the status before power failure This input signal has no effect while the START at PW ON signal is turned ON Normally read in START 1 Starts the timer The timer starts operating at the leading edge of...

Page 277: ... or both of these input signals The program at the specified bank can be changed or executed Banks 2 and 3 are selected by the corresponding input signal When the B2 and B3 signals are both OFF or when they are both ON at the same time bank 1 is selected Bank selection can be done in the PROG mode or in the RUN mode only when B3 Bank 3 selection can be done in the PROG mode or in the RUN mode only...

Page 278: ...2 V max OFF Vi 4 V min Terminal Arrangement Upper Terminals Terminal number D1 D2 D3 D4 D5 D6 D7 D8 Function OUTPUT MODE B2 B3 INHIBIT BATCH RESET RESET at PW ON START at PW ON INPUT COM Terminal number C1 C2 C3 C4 C5 C6 C7 C8 Function FORCED RUN START 1 START 2 GATE RESET OPER CHECK 1 OPER CHECK 2 INPUT COM Note Use the input common terminals even though they are internally connected to the outpu...

Page 279: ...tage 1 0 V max Leakage current 0 1 mA max Terminal Arrangement Bottom Terminals Terminal number A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 Function ALM RUN OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 S1 power S2 power Terminal number B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 Function BATCH READY OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 OUT 14 OUT 15 OUT 16 OUTPUT COM OUTPUT COM FG Note 1 Ter...

Page 280: ...A with Y92F 30 adapter or Signal OFF delay operation selectable Front screw SPDT H3BA FA Time limit operation self resetting ON delay operation 8 pin round socket SPDT SPDT H3BA 8H with P2CF 08 socket H3BA 8H with Y92F 30 adapter DPDT H3BA 8 with P2CF 08 socket H3BA 8 with Y92F 30 adapter Note 1 Specify both the model number and supply voltage when ordering 2 The operation resetting system is depe...

Page 281: ... note 1 Insulation resistance 100 M min at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying and non current carrying parts and between contact and control circuit 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistanc...

Page 282: ...selectors i e rated time selector and time unit selector RUN UP Indicator Time unit display Windows Rated Time Selector Operation Mode Selector Operation Mode Display Window Time Unit Selector Rated Voltage Classification Color Code Dial Digit Display Windows RUN UP Indicator Time Unit Display Window Rated Time Selector Operation Mode Selector Operation Mode Display Window Time Unit Selector Rated...

Page 283: ...he timer is in operation becomes invalid Repeat Cycle Operation B Mode Signal Start Power ON Start Power OFF Reset Note The minimum signal input time is 0 05 s Note The minimum resetting time is 0 15 s min Note The minimum resetting time is 0 1 s min Signal ON OFF delay Operation C Mode Note The minimum signal input time is 0 05 s Signal OFF delay Operation D Mode Note The minimum signal input tim...

Page 284: ...ow to Use Gate Signal Input Note 1 This timing chart indicates the gate input in opera tion mode A ON delay operation 2 The set time is the sum of t1 and t2 H3BA 8H H3BA 8 Note The minimum signal input time is 0 05 s ...

Page 285: ...t cover N 48n 2 5 1 0 With front cover N 48n 2 5 n 1 x 3 1 0 N 44 8 x 44 8 Accessories Order Separately Mounting Holes Note P2CF 11canbeused as a front connecting socket Track Front Mounting Socket P2CF 11 Terminal Arrangement Top View Mounting Height of Timer with Socket Two 4 5 dia mounting holes Two 4 5 dia holes Eleven M3 5 x 7 5 sems P2CF 08 Two 4 5 dia holes Two 4 5 dia or Two M4 Eight M3 5 ...

Page 286: ... Socket P3G 08 Mounting Holes Terminal Arrangement Bottom View Mounting Height of Timer with Socket PL11 Approx 20 5 Two 3 5 dia or M3 socket mounting holes Two 2 dia holes M3 5 35 max Two 2 dia holes Mounting Holes Terminal Arrangement Bottom View Mounting Height of Timer with Socket PL08 Two 3 5 dia or M3 socket mounting holes 27 dia 86 3 ...

Page 287: ... holes End Plate PFP M Spacers PFP S Adapter for Flush Mounting Y92F 30 Note Pay attention to the orientation of the adapter when mountingtwoormoretimers inavertical or horizontal line When mounting two or more timers in a vertical line arrange all the adapters so that their molded springs are positioned on the right and left sides When mounting two or more timers in a horizontal line arrange all ...

Page 288: ...t panel particularly the time setting section against dust dirt and water It also prevents the set value from being altered due to accidental contact with the time setting knob Note 1 TheY92A 48B ProtectiveCoverismadeofahardplastic and therefore it must be removed to change the timer set value 2 The Protective Cover cannot be mounted if the Panel Cover sold separately is used on the Timer Timing S...

Page 289: ...ver the contacts of H3BA are symbolized as because timer has four operation modes Refer to Application Examples Note 1 G Gate S Start R Reset 2 Conventional time limit contacts are symbolized as However the contacts of H3BA FA are symbolized as because timer has four operation modes Refer to Application Examples See note 2 See note 2 See note 2 H3BA 8H H3BA 8 ...

Page 290: ...ansistor with characteris tics VCEO 20V min VCE S 1Vmax IC 50mA min andICBO 0 5 A max In addition be sure that the input signals satisfy the fol lowing requirements 1 A resistance of 1 k max when the resister is ON 2 A residual voltage of 1 V max when the transistor is ON 3 A resistance of 200 k min when the transistor is OFF From a solid state circuit proximity sensor photoelectric sensor or the ...

Page 291: ...licationexamples Intheschematicdiagrams eachthicktheindicatesthewiringnecessaryfor selecting the desired operation mode ON delay Operation A Mode Power ON Start Power OFF Reset Signal Start Signal Reset Integrating Operation by Gate Signal Signal ON OFF delay Operation C Mode ...

Page 292: ...Cycle Operation B Mode Power ON Start Power OFF Reset Signal OFF delay Operation D Mode Power ON Start Instantaneous Operation Time limit Reset Signal Start Signal Reset Signal Start Instantaneous Operation Time limit Reset ...

Page 293: ...on can be turned in both directions clockwise and counter clockwise Each selector switch has a snap mechanism that se cures the switch at a given position Set the switch at a position at which it is secured Do not set it midway between two securingposi tions because such practice may causes the Timer to malfunction or in the worst case break down Accurately move and set the scale selector switch m...

Page 294: ...the internal circuit of the Timer may bedamagedduetothehigh tension voltageap plied to the input terminals Power Supply Connection If the Timer is connected to an AC power supply its two pole ter minals can be connected to the power supply in either direction regardless of the polarity But if it is connected to a DC power supply be sure to connect the Timer s power terminals to the correct polarit...

Page 295: ...operation time limit resetting forced resetting SPDT H3BH 8R with P2CF 08 socket H3BH 8R with Y92F 30 adapter Note Specify both the model number and supply voltage when ordering Accessories Order Separately Same as H3BA except for the following Timer Track mounted socket t 1 Back connecting socket see note 1 Solder terminal Screw terminal H3BH 8 8R P2CF 08 PL08 P3G 08 Note Track mounted socket can...

Page 296: ...500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying and non current carrying parts and between contact and control circuit 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfun...

Page 297: ...ation Color Code Operation Timing Chart H3BH 8 H3BH 8R Dimensions Note All units are in millimeters unless otherwise indicated Note Numbers in parentheses are reference value Panel Cutouts When mounting a single unit t 1 to 3 2 mm Horizontally connecting n units No front cover N 48n 2 5 1 0 With front cover N 48n 2 5 n 1 x 3 1 0 N ...

Page 298: ...H3BH H3BH 298 Installation Terminal Arrangement H3BH 8 H3BH 8R ...

Page 299: ...echanismthat securestheswitchat agiv en position Set the switch at a position at whichit is secured Donot set it midway between two securing positions because such prac ticemaycausestheTimertomalfunctionor intheworst case break down Accurately move and set the scale selector switch matching the 0 position mark to a division on the scale Wiring Sincethe H3BHuses ahigh impedance circuit the inducedv...

Page 300: ...of an AC power supply Use a DC power supply having a ripple factor of 20 or less and sup plying a mean voltage that is within the rated operating voltage range of the Timer Make sure that the supply voltage is applied to the Timer all at once using contacts such as of a switch or relay If the supply voltage is applied gradually the Timer may not be able to per form power reset or its set time may ...

Page 301: ...t SPST NO star circuit SPST NO d l H3BG 8 with P2CF 08 socket H3BG 8 with Y92F 30 adapter se esett g c cu t SPST NO delta circuit SPST NO H3BG 8H with P2CF 08 socket H3BG 8H with Y92F 30 adapter Front screw H3BG F SPST NO H3BG FH Note Specify both the model number and supply voltage when ordering Accessories Order Separately Same as H3BA except for the following exception Timer Track mounted socke...

Page 302: ...in at 500 VDC Dielectric strength 2 000 VAC 50 60 Hz for 1 min between current carrying and non current carrying parts and between contact and control circuit 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G ...

Page 303: ... Time Selector Rated Voltage Classification Color Code Dial Digit Display Windows Delta Operation Indicator Star delta Transfer Time Display Window Rated Star Time Selector Star Operation Indicator Star delta Transfer Time Selector Rated Voltage Classification Color Code Operation Timing Chart Note 1 The terminal numbers in parentheses apply to H3BG F H 2 Instantaneous contact is only available fo...

Page 304: ... dimension L between two adjacent timers should be 10 mm min H3BA FA Two 4 5 dia or M4 holes Panel Cutouts When mounting a single unit t 1 to 3 2 mm Horizontally connecting n units No front cover N 48n 2 5 1 0 With front cover N 48n 2 5 n 1 x 3 1 0 N Installation Internal Connection H3BG 8 8H See note Note Instantaneous contact is only available for H3BG 8H ...

Page 305: ...H3BG H3BG 305 H3BG F FH Note Instantaneous contact is only available for H3BG FH See note External Connection H3BG 8 H3BG 8H ...

Page 306: ...e lectorswitchhas asnapmechanismthat securestheswitchat agiv en position Set the switch at a position at whichit is secured Donot set it midway between two securing positions because such prac ticemaycausestheTimertomalfunctionor intheworst case break down Accurately move and set the scale selector switch matching the 0 position mark to a division on the scale Caution Donot changethetimeunit orope...

Page 307: ...in the rated operating voltage range of the Timer Make sure that the supply voltage is applied to the Timer all at once using contacts such as of a switch or relay If the supply voltage is applied gradually the Timer may not be able to per form power reset or its set time may be up when it should not Power Source Connection Because the AC operatedversion is a capacitiveload thesolid state relay to...

Page 308: ...pin round socket DPDT H3BF 8 with P2CF 08 socket H3BF 8 with Y92F 30 adapter Note Specify both the model number and supply voltage when ordering Accessories Order Separately Same as H3BA except for the following exception Timer Track mounted socket t 1 Back connecting socket see note 1 Solder terminal Screw terminal H3BF 8 P2CF 08 PL08 P3G 08 Note Track mounted socket can be used as a front connec...

Page 309: ...ween current carrying and non current carrying parts and between contact and control circuit 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 100 m s2 approx 10G Ambient temperature Operating 10 C...

Page 310: ...al Double Knob Dial Digit Display Windows Rated Time Selector Time Unit Display Window Operation Timing Chart Dimensions Note All units are in millimeters unless otherwise indicated H3BF 8 Panel Cutouts When mounting a single unit t 1 to 3 2 mm Horizontally connecting n units No front cover N 48n 2 5 1 0 With front cover N 48n 2 5 n 1 x 3 1 0 N ...

Page 311: ...ay windows Rated time selector Time unit display window Switch Setting The selector switches for time unit scale and function can be turnedinbothdirections clockwiseandcounterclockwise Eachse lectorswitchhas asnapmechanismthat securestheswitchat agiv en position Set the switch at a position at whichit is secured Donot set it midway between two securing positions because such prac ticemaycausestheT...

Page 312: ...in the rated operating voltage range of the Timer Make sure that the supply voltage is applied to the Timer all at once using contacts such as of a switch or relay If the supply voltage is applied gradually the Timer may not be able to per form power reset or its set time may be up when it should not Power Source Connection Because the AC operatedversion is a capacitiveload thesolid state relay to...

Page 313: ...le OMRON Products Temperature Controller ES100 E5AF E5EF Thermac X W S E5T E5P E5KN E5C2 E5C4 Timer H3CR H3B Series H3CA H5CR H2C H5CN H5BR H5AN Counter H8CA S H7CR H8PS H7BR H8BM H7CL H7AN H7CN Intelligent Signal Processor Digital Panel Meter K3TX K3TH K3TR K3TS K3TE see note K3TF K3TL Note Use the K32 L49MB sold separately for mounting Nomenclature Note Tighten the knurled screw to a torque of 0...

Page 314: ...therwise indicated Y92A 48N 48 x 48 mm Y92A 49N 48 x 96 mm Y92A 72N 72 x 72 mm Y92A 96N 96 x 96 mm Panel Cutout Y92A 48N 48 x 48 mm 29 4 21 9 2 2 21 9 29 4 131 7 131 7 115 6 67 6 69 12 2 21 9 14 87 7 79 2 67 6 107 7 91 6 21 9 2 29 4 Two 4 5 dia 69 0 3 45 0 6 0 dia Square hole ...

Page 315: ...en installing the Watertight Cover The front cover is made of polycarbonbate which can be cleaned using water methanol or ethanol Regularly check the packing the quality of which will deteriorate over the process of time The front cover can be mounted in any direction ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multipl...

Page 316: ...H3G 8A DPDT 1 s 3 s 5 s 10 s 30 s 30 s 60 s 3 min 5 min 10 min 30 min 60 min 3 hrs H3G 8C Note Specify both the model number supply voltage and rated time when ordering Ex H3G 8A 100 110 120 VAC 1 s Rated time Supply voltage Specifications Time Ranges Rated time Time range Rated time Time range 1 s 0 1 to 1 s 3 min 0 3 to 3 min 3 s 0 3 to 3 s 5 min 0 5 to 5 min 5 s 0 5 to 5 s 10 min 1 to 10 min 10...

Page 317: ... 10 to 55 Hz with 0 75 mm double amplitude Malfunction 10 to 55 Hz with 0 5 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 100 m s2 approx 10G Ambient temperature Operating 10 C to 55 C Ambient humidity Operating 35 to 85 Life expectancy Mechanical 10 000 000 operations min Electrical See Engineering Data Approved standards UL File No E41515 CSA File No LR22310...

Page 318: ...ons Note All units are in millimeters unless otherwise indicated Accessories Order Separately Adapter for Flush Mounting Y92F 31 Adapter Y92F 31 shown with H3G 8j and connecting socket Panel Cutout Recommended panel thickness 1 to 5 mm US08 Connecting Socket ...

Page 319: ...mer with Socket PF085A Mounting Holes Terminal Arrangement Top View Mounting Height of Timer with Socket Note PF085A can be used as a front connecting socket Eight M3 5 7 sems Eight M3 5 7 sems Two 4 2 dia holes Two 4 5 dia holes Two M4 or 4 5 dia holes Two M4 or 4 5 dia holes Mounting Clips Y92H 6 Connecting Socket US08 P3G 08 Terminal Arrangement Bottom View ...

Page 320: ...e This dimension applied to PFP 50N End Plate PFP M for Track Mounting Socket Spacer PFP S for Track Mounting Socket Installation Terminal Arrangement H3G 8A H3G 8C ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 03527 Cat No L33 E1 4 ...

Page 321: ...CT 8A Note Specify both the model number and supply voltage when ordering Example H3CT 8H 100 to 120 VAC B Supply voltage Time range code Model Number Legend H3CT 8j 1 1 Output Type A Time limit SPDT H Time limit SPDT instantaneous SPDT Accessories Order Separately Track Mounting Socket P2CF 08 Back Connecting Socket P3G 08 PL 08 Flush Mounting Adapter Y92F 30 Specifications General Item H3CT 8A H...

Page 322: ... at 250 VAC resistive load cos 1 Characteristics Accuracy of operating time 1 FS max 10 ms FS in ranges of 0 5 and 1 s Setting error 5 Influence of voltage 1 10 ms FS in range of 0 5 and 1 s Influence of temperature 2 10 ms FS in range of 0 5 and 1 s Insulation resistance 100 M Dielectric strength 2 000 VAC between current carrying metal parts and exposed non current carrying metal parts 2 000 VAC...

Page 323: ...cale selector at the lower right corner of the front panel Timing Charts Note 1 The minimum power operating time Rt is 0 1 s 2 The t in the timing charts stands for the set time H3CT 8A H3CT 8H t Rt t Power 2 to 7 NC 8 to 5 NO 8 to 6 Indicator G Indicator R t Rt t Power 2 to 7 NC 8 to 5 NO 8 to 6 Indicator G Indicator R NC 1 to 4 NO 1 to 3 Dimensions Note All units are in millimeters unless otherw...

Page 324: ...o M4 Eight M3 5 x 7 5 sems Two 4 5 dia holes 70 max 50 max 20 3 max 7 8 3 4 5 35 4 4 Back Connecting Socket P3G 08 Terminal Arrangement Internal Connections Bottom View 45 27 dia 45 4 9 17 Two 2 dia holes Mounting Holes Terminal Arrangement Bottom View PL08 Two 3 5 dia or 3M socket mounting holes Installation Terminal Arrangement Power supply H3CT 8A H3CT 8H Power supply ...

Page 325: ...nded to shield the input signal wiring to prevent electronic inter ference Organic solvents such as paint thinner as well as very acidic or basic solutions can damage the outer casing of the Timer Others If the Timer is mounted on a control board dismount the timer from the control board or short circuit the circuitry of the power board be fore carrying out a voltage withstand test between the ele...

Page 326: ...ized Distributor OMRON Corporation Systems Components Division 28th Fl Crystal Tower Bldg 1 2 27 Shiromi Chuo ku Osaka 540 Japan Phone 06 949 6012 Fax 06 949 6021 In the interest of product improvement specifications are subject to change without notice ...

Reviews: