Precautions When Connecting the Power Supplies
There are limits for each block to the capacities of the power supplies. The
total power consumption of the CompoNet Communications Unit and Smart-
Slice I/O Units must not be larger than 80 W. The total current consumption of
the I/O devices which connect to the SmartSlice I/O Units must not be larger
than 4 A.
If the current consumption or power consumption is too large, do the proce-
dure below.
Total Unit Power Consumption
1,2,3...
1. Refer to
Appendix D Power Consumption and Weight Tables
and calculate
the total power consumption. Include the CompoNet Communications Unit
and the connected SmartSlice I/O Units.
2.
If the total power consumption is larger than 80 W, connect a Right Turn-
back Unit (GRT1-TBR) where the total power consumption is 80 W or less.
Then connect a Left Turnback Unit (GRT1-TBL) to start a new block.
3.
Connect the Right Turnback Unit to the Left Turnback Unit with a Turnback
Cable (GCN2-100).
4.
Connect the Unit power supply (24 VDC) to the Unit power supply termi-
nals on the Left Terminal Block. Connect the I/O power supply (24 VDC) to
the I/O power supply terminals on the Left Terminal Block
Total I/O Current Consumption
1,2,3...
1.
Refer to
Appendix E Total I/O Current Consumption Table
and calculate the
total current consumption of all connected SmartSlice I/O Units. Include
the Turnback Unit.
2.
If the total current consumption is larger than 4 A, do one of these proce-
dures:
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
Right Turnback Unit
Total power consumption:
80 W maximum
Cable
connector
CompoNet
Communica-
tions Unit
I/O power
supply
(24 VDC)
I/O power
supply
(24 VDC)
End Unit
Turnback Cable
Left Turnback Unit
Same power supply as CompoNet
Communications Unit
Unit power
supply
(24 VDC)
• Connect all blocks to the same Unit power supply.
Precaution for
Correct Usage
Summary of Contents for GRT1-CRT - 05-2008
Page 1: ...CompoNet Communications Unit Cat No W476 E1 01 SmartSlice GRT1 CRT OPERATION MANUAL ...
Page 2: ...SmartSlice GRT1 CRT CompoNet Communications Unit Operation Manual Produced May 2008 ...
Page 3: ...iv ...
Page 17: ...About this Manual xviii ...
Page 28: ...9 Specifications Section 1 4 1 4 3 Dimensions 12 23 1 25 1 61 2 69 7 58 3 8 4 3 mm ...
Page 29: ...10 Specifications Section 1 4 ...
Page 39: ...20 Switches Section 2 3 ...
Page 47: ...28 Installing the Turnback Units Section 3 2 ...
Page 99: ...80 Last Maintenance Date Section 6 12 ...
Page 113: ...94 Performance of Message Communications Section 8 2 ...
Page 127: ...108 Other Error Causes and Error Procedures Section 9 3 ...
Page 141: ...122 Power Consumption and Weight Tables Appendix D ...
Page 143: ...124 Total I O Current Consumption Table Appendix E ...
Page 147: ...128 Index ...
Page 149: ...130 Revision History ...