Appendix C
Standard Models
CompoNet Communications Unit
SmartSlice I/O Units
Model
Specifications
GRT1-CRT
SmartSlice CompoNet Communications Unit
A total of 64 SmartSlice I/O Units can connect to one CompoNet Communica-
tions Unit.
Model
Specifications
GRT1-ID4
Four-point SmartSlice DC Input Unit, NPN
GRT1-ID4-1
Four-point SmartSlice DC Input Unit, PNP
GRT1-OD4
Four-point SmartSlice Transistor Output Unit, NPN
GRT1-OD4-1
Four-point SmartSlice Transistor Output Unit, PNP
GRT1-ID8
Eight-point SmartSlice DC Input Unit, NPN
GRT1-ID8-1
Eight-point SmartSlice DC Input Unit, PNP
GRT1-OD8
Eight-point SmartSlice Transistor Output Unit, NPN
GRT1-OD8-1
Eight-point SmartSlice Transistor Output Unit, PNP
GRT1-ROS2
Two-point SmartSlice Relay Output Unit
GRT1-AD2
Two-channel SmartSlice Analog Input Unit
GRT1-DA2C
Two-channel SmartSlice Analog Output Unit with Current Outputs
GRT1-DA2V
Two-channel SmartSlice Analog Output Unit with Voltage Outputs
GRT1-IA4-1
Four-point SmartSlice AC Input Unit (Input voltage: 100 to 120 VAC 50/60 Hz)
GRT1-IA4-2
Four-point SmartSlice AC Input Unit (Input voltage: 200 to 240 VAC 50/60 Hz)
GRT1-TS2T
Two-channel SmartSlice Temperature Input Unit for Thermocouples (input types: R, S, K,
J, T, B, L, E, U, N, W, and PL2)
GRT1-TS2P
Two-channel SmartSlice Temperature Input Unit for Pt100 Temperature Resistance Ther-
mometers
GRT1-TS2PK
Two-channel SmartSlice Temperature Input Unit for Pt1000 Temperature Resistance Ther-
mometers
GRT1-CT1
SmartSlice Counter Unit, NPN
GRT1-CT1-1
SmartSlice Counter Unit, PNP
GRT1-END
End Unit
GRT1-PD2
I/O Power Feed Unit
GRT1-PD8
I/O Power Feed Unit with overcurrent protection
GRT1-PD8-1
I/O Power Feed Unit, PNP, with 4 voltage and 8 ground terminals
GRT1-PC8
I/O Power Connection Unit, NPN, with 8 voltage and 4 ground terminals
GRT1-PC8-1
I/O Power Connection Unit, PNP, with 4 voltage and 8 ground terminals
GRT1-TBR
Right Turnback Unit
GRT1-TBL
Left Turnback Unit
GRT1-PD2G
I/O Power Feed Unit with overcurrent protection
GRT1-OD4G-1
Four-point Transistor Output Unit (PNP) with overcurrent and short-circuit protection
GRT1-OD4G-3
Four-point 2-A Transistor Output Unit (PNP) with overcurrent and short-circuit protection
GRT1-OD8G-1
Eight-point Transistor Output Unit (PNP) with overcurrent and short-circuit protection
GRT1-IA4-1
Four-point AC Input Unit (Input voltage: 100 to 120 VAC 50/60 Hz)
GRT1-IA4-2
Four-point AC Input Unit (Input voltage: 200 to 240 VAC 50/60 Hz)
Summary of Contents for GRT1-CRT - 05-2008
Page 1: ...CompoNet Communications Unit Cat No W476 E1 01 SmartSlice GRT1 CRT OPERATION MANUAL ...
Page 2: ...SmartSlice GRT1 CRT CompoNet Communications Unit Operation Manual Produced May 2008 ...
Page 3: ...iv ...
Page 17: ...About this Manual xviii ...
Page 28: ...9 Specifications Section 1 4 1 4 3 Dimensions 12 23 1 25 1 61 2 69 7 58 3 8 4 3 mm ...
Page 29: ...10 Specifications Section 1 4 ...
Page 39: ...20 Switches Section 2 3 ...
Page 47: ...28 Installing the Turnback Units Section 3 2 ...
Page 99: ...80 Last Maintenance Date Section 6 12 ...
Page 113: ...94 Performance of Message Communications Section 8 2 ...
Page 127: ...108 Other Error Causes and Error Procedures Section 9 3 ...
Page 141: ...122 Power Consumption and Weight Tables Appendix D ...
Page 143: ...124 Total I O Current Consumption Table Appendix E ...
Page 147: ...128 Index ...
Page 149: ...130 Revision History ...