S
ETUP
part
2
13
INPUT CONNECTION EXAMPLES
The figure below shows the wiring hookup for any thermocouple type. For
example, for Type K hookup, connect the yellow wire to the + (+S) Terminal and
the red wire to the Ð (ÐS) Terminal.
When configuring your controller, select
Thermocouple and Thermocouple type in the Input Type menu (see part 3).
2.5.1. Thermocouple
Figure 2.5.2 Thermocouple Wiring Hookup
TYPE
Input Connector
Jacket (external insulation)
Terminal 1 (-)
Terminal 2 (+)
Extension
Grade
J
Red
White
dark-Brown
Black
K
Red
Yellow
dark-Brown
Yellow
T
Red
Blue
dark-Brown
Blue
E
Red
Purple
dark-Brown
Purple
N
Red
Brown
dark-Brown
Brown
R
Red
Black
-
Green
S
Red
Black
-
Green
B
Red
Black
-
Black