10. Service Mode
Field Service Ver. 1.0 Jun. 2008
250
Adjustment / Setting
Mode
Default value
882
Bit
7654 3210
HEX: E0
State
1110 0000
Bit
Setting item
Setting value
Description
0
1
6
Color
o
B/W fallback function
OFF
ON
5
Color Reception
Not
allowed
Allowed
Sets whether to receive
color data or not.
4
Test scan
Disable
Enable
3
Calling port at the time of G3 fall back
G3-1
G3-2
1-0
Warm-up mode
*: In order to make this setting valid, main
power switch needs to be turned off and on
again twice.
00
Mode 1
01
Mode 2
10
Mode 3
11
Mode 4
Mode
Default value
883
Bit
7654 3210
HEX: 00 (for Europe)
HEX: 04 (for U.S)
State
0000 0000 (for Europe)
0000 0100 (for U.S)
Bit
Setting item
Setting value
Description
0
1
3
Power save setting
Immedi-
ately
Normal
Sets the method for shift-
ing to the power save
mode when operation is
complete, in the case of
recovering from lower
power or sleep mode with
recovering condition of no
unit operation.
2
LCT paper size
A4
8
1
/
2
x11
Sets the LCT paper size.
0
Optional original size detection sensor (BS)
No
Yes
Sets whether there is an
optional original size
detection sensor or not.
d-Color MF201
Service Manual Y109660-1