Field Service Ver. 1.0 Jun. 2008
10. Service Mode
207
Adjustment / Setting
Mode
Default value
368
Bit
7654 3210
HEX: 82
State
1000 0010
Bit
Setting item
Setting value
Description
0
1
7
Communication management report CSV
output
Not out-
put
Output
1
Communication log (TX) for scanner trans-
mission
Not print
Sets whether to print logs
in TX report, activity
report.
0
Result of communication received from an IP
Relay sending fax
Not print
Mode
Default value
370
Bit
7654 3210
HEX: FF
State
1111 1111
Bit
Setting item
Setting value
Description
0
1
7-0
Additional number of times to retry transmis-
sion (Network function)
Specify additional retrial times after retrying
the number of times specified by the user.
“0” indicates no additional retrial following the
current number of times specified by the user.
0000 0000
0
0000 0001
1
:
1111 1111
255
Mode
Default value
371
Bit
7654 3210
HEX: 40
State
0100 0000
Bit
Setting item
Setting value
Description
0
1
7-5
Retry interval for “additional number of times
to retry transmission” (Network function)
000
10 min.
001
15 min.
010
20 min.
011
25 min.
100
30 min.
others
Not available
1
Binary division
No
Yes
Sets Yes/No for binary
division during scan to e-
mail.
0
Page division
No
Yes
Sets Yes/No for page divi-
sion during Internet fax (e-
mail), scan to e-mail.
d
-Color
M
F
201
Y109660-1 Sevice Manual