Field Service Ver. 1.0 Jun. 2008
19. Image quality problem
337
T
roubleshooting
19.3.16
Printer monocolor: white lines in main scan direction, white bands in main
scan direction, colored lines in main scan direction, colored bands in main
scan direction
A. Typical faulty images
B. Troubleshooting procedure
A02EF4C508DA
White lines in main
scan direction
White bands in main
scan direction
Colored lines in main
scan direction
Colored bands in main
scan direction
Step
Section
Check item
Result
Action
1
Imaging unit The surface of the PC drum is
scratched.
YES
Change imaging unit.
2
Dirty on the outside.
YES
Clean.
3
Contact terminals make good con-
nection between each IU and
machine.
NO
Clean contact terminals.
4
Developing bias contact terminal
makes good connection.
NO
Clean contact terminal and check ter-
minal position.
5
PH unit
The surface of the PH window is
dirty.
YES
Clean with cleaning jig.
6
The problem has been eliminated
through the checks of steps up to 5.
NO
Change imaging unit.
o
Change transfer belt unit.
o
Change PH unit.
d
-Color
M
F
201
Y109660-1 Sevice Manual