6. Other
Field Service Ver. 1.0 Jun. 2008
58
Maintenance
B. Reinstall procedure
1.
Fit the back of the PH unit [1] into the
plate spring [2] of installation plate.
2.
Push the PH unit [1] along the right
side line of PH unit installation plate
all the way and fit it into the plate
spring [2].
3.
Make sure that the two bosses [3] at
front and rear side of the PH unit fit
in the locating hole [4].
4037F2C113DB
[1]
[2]
9J06F2C578DA
[3]
[4]
[3]
[4]
[2]
[1]
d-Color MF201