Field Service Ver. 1.0 Jun. 2008
10. Service Mode
245
Adjustment / Setting
Mode
Default value
505
Bit
7654 3210
HEX: 40
State
0100 0000
Bit
Setting item
Setting value
Description
0
1
6-5
Sound level of buzzer
00
Low
01
Normal
10
High
11
Not available
Mode
Default value
506
Bit
7654 3210
HEX: 00
State
0000 0000
Bit
Setting item
Setting value
Description
0
1
7-0
Auto reset extension time
Sets the period of time for the screen for
checking to be displayed when reaching to
the auto reset.
0000 0000
OFF
0000 0011
30 sec.
0000 0110
60 sec.
0000 1001
90 sec.
0000 1100
120 sec.
others
Not available
d
-Color
M
F
201