10. Service Mode
Field Service Ver. 1.0 Jun. 2008
146
Adjustment / Setting
10. Service Mode
10.1 Service Mode function setting procedure
NOTE
• Ensure appropriate security for Service Mode function setting procedures. They
should NEVER be shown to any unauthorized person not involved with service
jobs.
A. Procedure
1.
Press the Utility/Counter key.
2.
Touch [Check Details].
3.
Press the following keys in this order; Stop
o
0
o
0
o
Stop
o
0
o
1
NOTE
• When selecting [CE Authentication] under [Security Settings] available from Ser-
vice Mode, authentication by CE password is necessary.
Enter the 8 digits CE password, and touch [END].
(The initial setting for CE password is “92729272.”)
• NEVER forget the CE password. When forgetting the CE password, it becomes
necessary to replace the RAMU board with a new one and call responsible person
of KMBT.
• The service code entered is displayed as “
✽
.”
4.
The Service Mode menu will appear.
NOTE
• Be sure to change the CE password from its default value.
• For the procedure to change the CE password, see the Security Settings.
See P.268
B. Exiting
• Touch the [OK] key.
NOTE
• When changing the setting value in service mode, make sure to turn main power
switch off once and turn it on again.
C. Changing the setting value in Service Mode functions
• Use the [+] / [-] key to enter or change the setting value.
• Use the 10-key pad to enter the setting value. (To change the setting value, first press the
Clear key before making an entry.)
A02FF3E517DA
d-Color MF201
Service Manual Y109660-1