Field Service Ver. 1.0 Jun. 2008
10. Service Mode
251
Adjustment / Setting
10.5.11
Consumable Life Reminder
10.5.12
Unit Change
10.5.13
Option Settings
Mode
Default value
884
Bit
7654 3210
HEX: 01
State
0000 0001
Bit
Setting item
Setting value
Description
0
1
0
Fan control for the low-temperature warm-up
*: In order to make this setting valid, main
power switch needs to be turned off and on
twice.
Valid
Invalid
Sets the valid/invalid of
the fan control function
which further prevents the
waviness of the paper
when printing immediately
after the warm-up in low
temperature.
Functions
• To select whether or not to give the display of PM parts lifetime
PM parts lifetime display: An entire screen warning is given when the service life
of a specific unit has been reached, prompting the
user to replace the part.
• Applicable units:
Transfer belt unit, fusing unit, imaging unit (C, M, Y, K)
Use
• Use to select not to give the display of PM parts lifetime.
Setting/
Procedure
• The default setting is “Yes.”
“Yes”
No
Functions
• To select who is to replace a unit.
• When the unit life arrives, the warning display is intended for the specific person who
is going to replace the unit.
When “User” is selected
: Printing is inhibited.
When “Service” is selected: Life warning.
Use
• Upon setup
Setting/
Procedure
<Unit Change>
• The following are the default settings:
US, Japan, Others 2 Europe, Others1,3,4
Toner Cartridge
: “User” Service
“User”
Service
Imaging Unit
: User
“Service”
“User”
Service
Waste Toner Box
: User
“Service”
“User”
Service
Functions
• To set the status for the optional stamp unit SP-503.
Use
• To be used for setting up the stamp unit SP-503.
Setting/
Procedure
• The default setting is “No.”
Yes
“No”
d
-Color
M
F
201