10. Service Mode
Field Service Ver. 1.0 Jun. 2008
192
Adjustment / Setting
Mode
Default value
322
Bit
7654 3210
HEX: 00
State
0000 0000
Bit
Setting item
Setting value
Description
0
1
6-0
Setting printing area for ADF back side poste-
rior end 2 (D).
Set so that the value is less than that on
mode 321 bit [6-0].
0000000
0 mm
0000001
1 mm
:
1000010
66 mm
others
Not available
Mode
Default value
323
Bit
7654 3210
HEX: 80
State
1000 0000
Bit
Setting item
Setting value
Description
0
1
7-6
ACS parameter setting for ADF back side
leading edge (2).
00
Parameter for center
(closer to the full color)
01
Parameter 1 closer to
black
10
Parameter 2 closer to
black
11
Parameter 3 closer to
black (closer to black)
d-Color MF201
Service Manual Y109660-1