10. Service Mode
Field Service Ver. 1.0 Jun. 2008
198
Adjustment / Setting
Mode
Default value
350
Bit
7654 3210
HEX: 28
State
0010 1000
Bit
Setting item
Setting value
Description
0
1
6
POP3 before SMTP
No
Yes
5-4
Maximum width of document to be transmit-
ted when the fax capability of the receiver is
set to [Advanced]
(Network function)
00
A4
Default
value of
maximum
width of
document to
be transmit-
ted
01
B4
10
A3
11
Not avail-
able
3-2
Maximum resolution to be used when the fax
capability of the receiver is set to [Advanced]
(Network function)
00
200 x 200
dpi
Default
value of
maximum
resolution to
be used
01
400 x 400
dpi
10
600 x 600
dpi
11
Not avail-
able
Mode
Default value
351
Bit
7654 3210
HEX: 1C
State
0001 1100
Bit
Setting item
Setting value
Description
0
1
7
Gateway transmission (Network function)
Not
allowed
Allowed
Specify allowed or not
allowed for sending e-mail
using gateway communi-
cations.
If “Not allowed”, SMTP
reception is executed,
however gateway trans-
mission is not executed,
and received data is
printed.
6-5
Outgoing port for gateway transmission (Net-
work function)
Specify an outgoing port for fax transfer (fax
transfer of received e-mail file) through gate-
way transmission.
(valid for G3 multi-port only) [See note.]
00
G3-1
11
G3-2
others
Not available
3
Gateway TSI
Normally
not add
Normally
add
d-Color MF201
Service Manual Y109660-1