Field Service Ver. 1.0 Jun. 2008
3. Periodical check
25
Maintenance
C. Reinstall procedure
1.
Insert the transfer belt unit [1].
NOTE
• Insert the transfer belt unit with
care not to allow its docking gear to
be damaged by hitting it against the
rail or associated part.
• Do not touch the surface of the
image transfer belt unit.
• Cover the image transfer belt unit
with something such shade cloth to
protect its surface from dust or for-
eign matter.
2.
Install the transfer belt unit with two
screws [1].
NOTE
• Replace the ozone filter, which is
supplied with the transfer belt unit,
at the same time.
3.
Close the right door.
4.
Turn ON the main power switch.
5.
Select [Service Mode]
o
[Imaging Process Adjustment]
o
[Gradation Adjust] and
carry out gradation adjust.
See P.164
A02FF2C009DA
[1]
A02FF2C010DA
[1]