Field Service Ver. 1.0 Jun. 2008
17. Malfunction code
307
T
roubleshooting
17.5.33
C3301: Fusing cooling fan motor/ 1 failure to turn
17.5.34
C3302: Fusing cooling fan motor/ 2,3 failure to turn
Relevant parts
Fusing cooling fan motor (FM13)
Printer control board (PRCB)
Step
Action
WIRING DIAGRAM
Control signal
Location (Electri-
cal component)
1
Check the FM13 connector for proper
connection and correct as necessary.
—
—
2
Check the fan for possible overload and
correct as necessary.
—
—
3
FM13 operation check
PRCB CN31-4 (REM)
PRCB CN31-5 (LOCK)
C to D-26
4
Change FM13
—
—
5
Change PRCB
—
—
Relevant parts
Fusing cover cooling fan motor (FM11)
Printer control board (PRCB)
Step
Action
WIRING DIAGRAM
Control signal
Location (Electri-
cal component)
1
Check the FM11 connector for proper con-
nection and correct as
necessary.
—
—
2
Check the fan for possible overload and
correct as necessary.
—
—
3
FM11 operation check
PRCB CN31-7 (REM)
PRCB CN31-8 (LOCK)
C to D-26
4
Change FM11
—
—
5
Change PRCB
—
—
d
-Color
M
F
201
Y109660-1 Sevice Manual