Field Service Ver. 1.0 Jun. 2008
3. Periodical check
9
Maintenance
Maintenance
3.
Periodical check
3.1
Maintenance items
NOTE
• Cleaning/replacement cycle for each maintenance item of main body/options can
be evaluated with each life counter value of [Service mode]
o
[Counter]
o
[Life].
3.1.1
Main body
A. Parts to be replaced by users (CRU)
*1: The parts can be replaced either by user or service engineer.
For details of setting, see [Unit Change] on “Adjustment/Setting.”
See P.251
*2: A waste toner full condition is detected with detecting the actual waste toner emissions.
B. Maintenance call (per 30,000-sheet scan)
C. Maintenance call (per 60,000-print)
No
Class
Parts to be replaced
Cycle
Clean Replace
Descrip-
tions
1
Processing
sections
Imaging unit Y,M,C
45,000
●
*1
2
Imaging unit K
60,000
●
*1
3
Toner cartridge Y,M,C
18,500
●
*1
4
Toner cartridge K
24,000
●
*1
5
Image transfer
section
Waste toner box
(50,000)
●
*1,2
No.
Class
Parts to be replaced
Qt.
Check
Clean
Replace
Lubri-
cation
Descrip-
tions
1
Overall
Paper feed and image
conditions
●
2
Appearance
●
●
3
Scanner
section
Original glass assy
●
No.
Class
Parts to be replaced
Qt.
Check
Clean
Replace
Lubri-
cation
Descrip-
tions
1
Overall
Paper feed and image
conditions
●
2
Appearance
●
●
3
Conveyance
section
Timing roller
●
4
Image transfer
section
Around waste toner port
●
5
AD-505
Duplex transport roller
●
Y109660-1 Sevice Manual