10. Service Mode
Field Service Ver. 1.0 Jun. 2008
242
Adjustment / Setting
Mode
Default value
492
Bit
7654 3210
HEX: 6C
State
0110 1100
Bit
Setting item
Setting value
Description
0
1
7-5
Select sound volume 1. (Buzzer) (Key)
6 stage adjustment of key buzzer
000
0 (No sound)
001
1
010
2
011
3
100
4
101
5
others
Not available
4-2
Select sound volume 2. (Alarm)
6 stage adjustment of key buzzer
000
0 (No sound)
001
1
010
2
011
3
100
4
101
5
others
Not available
Mode
Default value
493
Bit
7654 3210
HEX: 68 (for Europe)
HEX: 64 (for U.S)
State
0110 1000 (for Europe)
0110 0100 (for U.S)
Bit
Setting item
Setting value
Description
0
1
7-5
Monitor sound volume
6 stage adjustment of line monitor
000
0 (No sound)
001
1
010
2
011
3
100
4
101
5
others
Not available
1-0
Select priority application. (after auto clear
and panel reset)
Selects initial screen (Copy or Fax/Scan).
00
Copy
01
Fax/Scan
others
Not available
d-Color MF201