Solution System
105
Service Manual – SC1500
Specifications
Component Specifications
Component
Specifications
Solution Solenoid Valve
Nominal Voltage – 24 VDC, 11 Watt
Duty – Continuous
Resistance – 55.5 Ohms ±10% @ 25° C
Solution Tank
Capacity – 12 gal. [45,4 l]
Detergent Pump
Flow per Stroke – 0.3 ml
Flow per Minute – 63 ml
Motor Type – Linear Drive
Nominal Voltage – 24 VDC
Pump Solenoid Coil Resistance – 38.5 Ohms
Pulse Frequency – 3.5 Hz
Pulse Width – 110 ms
Pulse Current – 0.7 A
Pulse Power Consumption – 15 W
Detergent Cartridge
Capacity
1 gallon [4 liters]
Nominal Solution Flow Rates
The nominal solution flow are listed in the following table. Note that these flow rates are based on a half-full
solution tank.
Solution
Setting
Deck Type
Nominal Flow Rate
Low
20” Disk
0.15 (gal./min.) / 0.57 l/min.
Medium
20” Disk
0.35 (gal./min.) / 1.32 l/min.
High
20” Disk
0.50 (gal./min.) / 1.89 l/min.
Low
20” REV
™
0.1 (gal./min.) / 0.38 l/min.
Medium
20” REV
™
0.165 (gal./min.) / 0.62 l/min.
High
20” REV
™
0.219 (gal./min.) / 0.83 l/min.