Wheel System - Traction
119
Service Manual – SC1500
Maintenance and Adjustments
Speed Control Programming Options
The following table lists the Speed Control parameters that can be accessed and changed using the 1311
Programmer. Note that these parameters normally do not need to be changed, and should not be changed
arbitrarily.
Parameter
as listed
on the 1311
Programmer
Range
Factory
Setting
Units
Function
Accel Max
Speed
0.2-4.0
4.0
Sets the forward acceleration rate with the speed potentiometer set
at maximum. Smaller numbers provide faster response.
Accel Min
Speed
0.2-8.0
4.0
Sets the forward acceleration rate with the speed potentiometer set
at minimum. Smaller numbers provide faster response.
Reverse
Accel Max
0.2-8.0
5.0
Sets the reverse acceleration rate with the speed potentiometer set
at maximum. Smaller numbers provide faster response.
Reverse
Accel Min
0.2-8.0
5.0
Sets the reverse acceleration rate with the speed potentiometer set
at minimum. Smaller numbers provide faster response.
M1 Max
Speed
0-100
100
%
The speed requested in forward with the throttle and speed limit
pot set to maximum in mode 1 (only Mode 1 is available).
M2 Max
Speed
0-100
100
%
Mode 2 is not available