General Information
22
Service Manual – SC1500
•
Vacuum Level Bar Graph
– displays the vacuum motor power mode as follows:
• Bottom box filled – low/quiet mode (as shown).
• Top and bottom boxes filled – high/standard mode.
• Both boxes empty – vacuum motor off.
Information Switch
•
Information Switch
– displays the Information Screen on the
graphic display. The Information Screen will also be displayed
if a significant error occurs that results in the shutdown of
some machine system. The graphic display will then display
the Information screen until next key switch cycle.
The Information Screen shows the
Hour Meter
,
Fault Codes
and
the
Battery Charge Level Indicator
•
Hour Meter
– displays the total number of run hours on the
machine.
•
Fault Codes
– displays the wrench icon
and any active
two-digit fault code. If more than one error exists, the display
will sequence through the error codes at one-second intervals.
(Refer to the
Fault Codes
subsection in the
Control System
section.)
•
Battery Charge Level Indicator
– indicates the charge level of the batteries according to the number of filled
“bars” in the battery icon.
• Five solid bars indicates a full battery charge.
• No solid bars (empty battery icon) indicates that the batteries are discharged.
Battery Status and Charger Screens
•
Battery Low Voltage Screen
– displayed when the battery
voltage drops to approximately 21.75 volts. The graphic
display will alternate between the Battery Status Screen
and the “normal” display at five-second intervals to alert the
Operator that the batteries need charging and the remaining
battery time is very short.
Note that:
• When the voltage in AGM or Gel batteries drops to 21.75 volts, the A1 Control Board switches off the
scrub motor, solution system and detergent pump, and raises the scrub deck. The vacuum motor can
still remain on.
• When the voltage in AGM or Gel batteries drops to 21.6 volts, the A1 Control Board switches off the
vacuum motor.
• When the voltage in Wet batteries drops to 20.55 volts, the A1 Control Board switches off the scrub
motor, solution system and detergent pump, and raises the scrub deck. The vacuum motor can still
remain on.
• When the voltage in Wet batteries drops to 20.4 volts, the A1 Control Board switches off the vacuum
motor.