![NEC N8100-1078F User Manual Download Page 242](http://html1.mh-extra.com/html/nec/n8100-1078f/n8100-1078f_user-manual_4225291242.webp)
9-24 Upgrading Your Server
Using Internal Disks in Disk Array Configuration
For the installation of the RAID controller board, see "PCI Board" and the manual that comes with
the RAID controller board. The DISK access lamp on the front panel of the server indicates the
access status of the hard disk drive connected to the RAID controller board. Before the access status
can be indicated, the LED connector on the RAID controller board and the LED connector on the
mother board must be connected through the LED cable supplied with the server.
Mother Board
The LED connector is at the position shown in the figure below. It can be connected in
either direction.
RAID Controller Board
The red cable of the LED cable comes out from the connector hole. Connect the connector
hole to "LED Active" of the LED connector on the RAID controller board. For the
position of the LED Active pin, see the manual supplied with the RAID controller board.
Use the interface cable supplied with the RAID controller board. Disconnect the current cable from
the server and keep it in a designated place. For details on the cable connection, see the manual
supplied with the RAID controller board.
After installing the RAID controller board, make settings such as RAID setting, using the disk array
BIOS utility of the RAID controller board. For details on the setting procedures, see the manual
supplied with the RAID controller board.
Face this side
upward.
To the mother board
LED cable
To the RAID
controller
Connect 2-pin LED cable.
Summary of Contents for N8100-1078F
Page 16: ...x This page is intentionally left blank...
Page 34: ...2 6 General Description Rear View 1 2 3 13 12 11 10 9 8 7 6 5 4...
Page 36: ...2 8 General Description Internal View 1 2 4 4 4 3 4 2 4 1 5 6 7 8 3...
Page 100: ...4 32 Configuring Your Server This page is intentionally left blank...
Page 150: ...5 50 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 170: ...6 20 Installing and Using Utilities This page is intentionally left blank...
Page 182: ...7 12 Maintenance This page is intentionally left blank...
Page 257: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Page 268: ...A 2 Specifications This page is intentionally left blank...
Page 278: ...C 4 IRQ and I O Port Address This page is intentionally left blank...
Page 328: ...F 18 Installing Windows 2000 This page is intentionally left blank...