![background image](http://html1.mh-extra.com/html/nec/n8100-1078f/n8100-1078f_user-manual_4225291147.webp)
Installing the Operating System with Express Setup 5-47
HostRAID
The following explains the overview of HostRAID and the setup procedure.
Overview of HostRAID
HostRAID provides RAID feature through the onboard serial ATA interface in your system.
HostRAID consists of the driver that controls disk arrays and "Adaptec Storage Manager™ -
Browser Edition" (hereinafter referred to as "ASMBE") that is a disk array management utility.
The software products are mandatory for HostRAID to function normally. Be sure to install both
software products. For the driver, refer to the setup procedure explained in this manual. For
ASMBE, refer to the "Adaptec Storage Manager™ - Browser Edition User's Guide."
Overview of the specifications
Hard disk drive:
One hard disk drive for each channel (two hard disk drives
max.)
RAID level:
RAID0 or RAID1
Operating system:
Microsoft Windows Server 2003 Standard Edition/
Enterprise Edition
Microsoft Windows Server 2003 x64 Editions
Microsoft Windows 2000 Server/Advanced Server
Configuration Method of disk arrays:
BIOS setup utility, NEC EXPRESSBUILDER and
ASMBE
Features
HostRAID enables the BIOS utility to select the disk array/standard SATA for each
channel.
Since the JAVA-based management utility ASMBE uses the browser (IE5.5 or later), the
software does not need to be installed into each client PC for management. (The software
must be installed in each server.)
Summary of Contents for N8100-1078F
Page 16: ...x This page is intentionally left blank...
Page 34: ...2 6 General Description Rear View 1 2 3 13 12 11 10 9 8 7 6 5 4...
Page 36: ...2 8 General Description Internal View 1 2 4 4 4 3 4 2 4 1 5 6 7 8 3...
Page 100: ...4 32 Configuring Your Server This page is intentionally left blank...
Page 150: ...5 50 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 170: ...6 20 Installing and Using Utilities This page is intentionally left blank...
Page 182: ...7 12 Maintenance This page is intentionally left blank...
Page 257: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Page 268: ...A 2 Specifications This page is intentionally left blank...
Page 278: ...C 4 IRQ and I O Port Address This page is intentionally left blank...
Page 328: ...F 18 Installing Windows 2000 This page is intentionally left blank...