![NEC N8100-1078F User Manual Download Page 195](http://html1.mh-extra.com/html/nec/n8100-1078f/n8100-1078f_user-manual_4225291195.webp)
Troubleshooting 8-13
Fail to power off the server:
T
Is the POWER switch enabled?
→
Restart the server and start the BIOS SETUP utility.
<Menu to check: [Security] - [Power Switch Inhibit]>
T
Is the server running in the Secure Mode?
→
The POWER switch is disabled in the Secure Mode. (Forced shutdown is also
not available.) To release the Secure Mode, enter the password specified with the
BIOS SETUP utility.
POST fails to complete:
T
Is the DIMM board installed?
→
At least two DIMM boards are required for operation.
→
DIMMs must be populated in pairs and in the following order:
#1A and #1B, and then #2A and #2B.
→
Installed DIMMs starting from the one having largest memory.
T
Is the memory size large?
→
The memory check may take a few seconds if the memory size is large. Wait for
a while.
T
Did you perform any keyboard or mouse operation immediately after you started the
server?
→
If you perform any keyboard or mouse operation immediately after start-up, POST
may accidentally detect a keyboard controller error and stops proceeding. In
such a case, restart the server once again. Do not perform any keyboard or
mouse operation until the BIOS start-up message appears when you restart the
server.
T
Does the server have contains appropriate memory boards or PCI devices?
→
Operation of the server with unauthorized devices is not guaranteed.
Summary of Contents for N8100-1078F
Page 16: ...x This page is intentionally left blank...
Page 34: ...2 6 General Description Rear View 1 2 3 13 12 11 10 9 8 7 6 5 4...
Page 36: ...2 8 General Description Internal View 1 2 4 4 4 3 4 2 4 1 5 6 7 8 3...
Page 100: ...4 32 Configuring Your Server This page is intentionally left blank...
Page 150: ...5 50 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 170: ...6 20 Installing and Using Utilities This page is intentionally left blank...
Page 182: ...7 12 Maintenance This page is intentionally left blank...
Page 257: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Page 268: ...A 2 Specifications This page is intentionally left blank...
Page 278: ...C 4 IRQ and I O Port Address This page is intentionally left blank...
Page 328: ...F 18 Installing Windows 2000 This page is intentionally left blank...