![NEC N8100-1078F User Manual Download Page 194](http://html1.mh-extra.com/html/nec/n8100-1078f/n8100-1078f_user-manual_4225291194.webp)
8-12 Troubleshooting
SOLVING PROBLEMS
When the server fails to operate as expected, see the following to find out your problem and follow
the instruction given before asking for repair.
If the server still fails to operate successfully after solving your problem, take a note on the on-
screen message and contact your sales agent.
Problems with NEC Express Server
No screen display appears with beep:
T
Are DIMMs installed securely?
→
Check whether DIMMs are connected to the mating connectors firmly.
→
Check whether DIMMs of different specifications are installed in the specific
bank. See Chapter 9 for the specifications of DIMMs.
→
DIMMs must be populated in pairs and in the following order:
#1A and #1B, and then #2A and #2B.
→
Installed DIMMs must be the same speed and must all be registered.
When two pairs of the DIMMs are installed, the largest pair of the DIMMs must
be installed to slots #2A and #2B.
→
Installed DIMMs starting from the one having largest memory.
→
Take a note of beep code pattern, and take appropriate action according to the
table listed earlier in "Beep Codes".
Fail to power on the server:
T
Is the server is properly supplied with power?
→
Check if the power cord is connected to a power outlet (or UPS) that meets the
power specifications for the server.
→
Make sure to use the power cord provided with the server. Check the power cord
for broken shield or bent plugs.
→
Make sure the power breaker for the connected power outlet is on.
→
If the power cord is plugged to a UPS, make sure the UPS is powered and it
outputs power. See the manual that comes with the UPS for details.
Power supply to the server may be linked with the connected UPS using the BIOS
SETUP utility of the server.
<Menu to check: [Server] - [Resume on AC Power Loss]>
T
Did you press the POWER switch?
→
Press the POWER switch on the front of the server to turn of the power (the
POWER/SLEEP lamp lights).
Summary of Contents for N8100-1078F
Page 16: ...x This page is intentionally left blank...
Page 34: ...2 6 General Description Rear View 1 2 3 13 12 11 10 9 8 7 6 5 4...
Page 36: ...2 8 General Description Internal View 1 2 4 4 4 3 4 2 4 1 5 6 7 8 3...
Page 100: ...4 32 Configuring Your Server This page is intentionally left blank...
Page 150: ...5 50 Installing the Operating System with Express Setup This page is intentionally left blank...
Page 170: ...6 20 Installing and Using Utilities This page is intentionally left blank...
Page 182: ...7 12 Maintenance This page is intentionally left blank...
Page 257: ...Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Page 266: ...10 10 Internal Cabling Diagrams This page is intentionally left blank...
Page 268: ...A 2 Specifications This page is intentionally left blank...
Page 278: ...C 4 IRQ and I O Port Address This page is intentionally left blank...
Page 328: ...F 18 Installing Windows 2000 This page is intentionally left blank...