8-36 Troubleshooting
Problems with RAID System Configuration
Fail to install the OS:
Did you create virtual disk?
→
Create virtual disks by using WebBIOS.
Fail to start the OS:
Is RAID controller inserted firmly straight into the PCI slot?
→
Install the RAID controller properly.
Is the RAID controller installed in the proper slot?
→
Check if the slot is appropriate to the RAID controller. If the same error persists,
the RAID controller may be faulty. Contact your service representative.
Are hard disk drives properly installed?
→
Install them properly.
Is SAS cable connected correctly? (Check connection status with the server, hard disk
drives, and additional HDD cage.)
→
Connect the SAS cable properly.
If the same error persists, the hard disk drive may be faulty. Contact your service
representative.
A hard disk drive fails:
→
Contact your service representative.
Rebuild fails:
Is the capacity of the hard disk drive to be rebuilt sufficient?
→
The hard disk drive to be rebuilt should have the same capacity of the failed had
disk drive.
Is RAID0 configured for virtual disk?
→
RAID0 has no data redundancy, therefore, Rebuild is disabled in the RAID0
configuration. Replace the failed hard disk drive, then create the virtual disk again.
Check Consistency fails:
Is virtual disk "Degraded"?
→
Replace the failed hard disk drive with new one, then perform Rebuild.
Is RAID0 configured for virtual disk?
→
RAID0 has no data redundancy, therefore, Check Consistency is disabled in the
RAID0 configuration.
Summary of Contents for Express5800/T120a-E N8100-1531F
Page 56: ...2 26 General Description This page is intentionally left blank ...
Page 70: ...3 14 Setting Up Your Server This page is intentionally left blank ...
Page 125: ...Configuring Your Server 4 55 Property of Physical Device of Universal RAID Utility ...
Page 178: ...4 108 Configuring Your Server This page is intentionally left blank ...
Page 276: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Page 290: ...7 14 Maintenance This page is intentionally left blank ...
Page 416: ...9 70 Upgrading Your Server This page is intentionally left blank ...
Page 428: ...A 4 Specifications This page is intentionally left blank ...
Page 436: ...C 2 IRQ This page is intentionally left blank ...
Page 475: ...Installing Windows Server 2008 D 39 4 Activate Windows The Windows activation is complete ...
Page 538: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 542: ...H 4 Product Configuration Record Table This page is intentionally left blank ...