8-18 Troubleshooting
On-screen message
Action
Your VDs that are configured for write-back
are temporarily running in write-through
mode.
This is caused by the battery being charged,
missing, or bad.
Please allow battery to charge for 24 hours
before evaluating battery for replacement.
The following VDs are affected :XX
Press any key to continue.
<When battery is not used>
Ignore this message.
<When battery is used>
Run WebBIOS or Universal RAID Utility to check if
battery is detected.
•
Battery is not detected:
– Check if battery is connected properly.
– Battery may be insufficiently charged. Halt the
system for 24 hours or longer and charge
battery.
•
Battery is detected:
– Halt the system for 9 hours or longer and
charge battery.
If the same error persists, contact your service
representative.
Invalid SAS Address present in MFC data.
Please program valid SAS Address, and
restart your system.
Contact your service representative.
Some configured disks have been removed
from your system, or are no longer
accessible. Please check your cables and
also ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
The following VDs have missing disks: xx
If you proceed (or load the configuration
utility), these VDs will be marked OFFLINE
and will be inaccessible.
Please check your cables and ensure all
disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
The following VDs are missing: xx
If you proceed (or load the configuration
utility), these VDs will be removed from your
configuration. If you wish to use them at a
later time, they will have to be imported. If
you believe these VDs should be present,
please power off your system and check
your cables to ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
All of the disks from your previous
configuration are gone. If this is an
unexpected message, then please power off
your system and check your cables to
ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
Check if cable and hard disk drives are connected
properly. If the same error persists, contact your
service representative.
Summary of Contents for Express5800/T120a-E N8100-1531F
Page 56: ...2 26 General Description This page is intentionally left blank ...
Page 70: ...3 14 Setting Up Your Server This page is intentionally left blank ...
Page 125: ...Configuring Your Server 4 55 Property of Physical Device of Universal RAID Utility ...
Page 178: ...4 108 Configuring Your Server This page is intentionally left blank ...
Page 276: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Page 290: ...7 14 Maintenance This page is intentionally left blank ...
Page 416: ...9 70 Upgrading Your Server This page is intentionally left blank ...
Page 428: ...A 4 Specifications This page is intentionally left blank ...
Page 436: ...C 2 IRQ This page is intentionally left blank ...
Page 475: ...Installing Windows Server 2008 D 39 4 Activate Windows The Windows activation is complete ...
Page 538: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 542: ...H 4 Product Configuration Record Table This page is intentionally left blank ...