Troubleshooting 8-17
Messages displayed by RAID Controller during POST
On-screen message
Action
Memory/battery problems were detected.
The adapter has recovered, but cached data
was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Firmware version inconsistency was
detected.
The adapter has recovered, but cached data
was lost.
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
Foreign configuration(s) found on adapter
Press any key to continue, or 'C' to load the
configuration utility.
Press
C
to run the utility to import or clear
configuration.
Previous configuration cleared or missing
Importing configuration created on
MM/DD hh:mm
Press any key to continue, or 'C' to load the
configuration utility.
Contact your service representative.
An enclosure was found that contains both
SAS and SATA drives, but this controller
does not allow mixed drive types in a single
enclosure. Please correct the problem then
restart your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SAS drives were detected, but this controller
does not support SAS drives.
Please remove the SAS drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
SATA drives were detected, but this
controller does not support SATA drives.
Please remove the SATA drives then restart
your system.
Press any key to continue, or 'C' to load the
configuration utility.
RAID Controller may be faulty. Contact your service
representative to replace the RAID controller.
Invalid SAS topology detected. Please
check your cable configurations, repair the
problem, and restart your system.
Check if cable is connected properly. If the same
error persists, contact your service representative.
The battery hardware is missing or
malfunctioning, or the battery is unplugged.
If you continue to boot the system, the
battery-backed cache will not function.
Please contact technical support for
assistance.
Press 'D' to disable this warning (if your
controller does not have a battery).
<When battery is not used>
Press
D
to hide this message.
<When battery is used>
Check if battery is connected properly. If the same
error persists, contact your service representative.
Summary of Contents for Express5800/T120a-E N8100-1531F
Page 56: ...2 26 General Description This page is intentionally left blank ...
Page 70: ...3 14 Setting Up Your Server This page is intentionally left blank ...
Page 125: ...Configuring Your Server 4 55 Property of Physical Device of Universal RAID Utility ...
Page 178: ...4 108 Configuring Your Server This page is intentionally left blank ...
Page 276: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Page 290: ...7 14 Maintenance This page is intentionally left blank ...
Page 416: ...9 70 Upgrading Your Server This page is intentionally left blank ...
Page 428: ...A 4 Specifications This page is intentionally left blank ...
Page 436: ...C 2 IRQ This page is intentionally left blank ...
Page 475: ...Installing Windows Server 2008 D 39 4 Activate Windows The Windows activation is complete ...
Page 538: ...G 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 542: ...H 4 Product Configuration Record Table This page is intentionally left blank ...