3-14
Configuring Your System
Server Menu
Feature
Choices or
Display Only
Description
Your Setting
System
Management
Selects sub-menu.
Console
Redirection
Selects sub-menu.
Service Partition
Type
1 to 255
Displays the partition type of
the Service Partition; the
default is 12h.
Clear Event Log
Enter
If selected, the System Event
log will be cleared
immediately.
Assert NMI on
PERR
Disabled
Enabled
If enabled, PCI bus parity
error (PERR) is enabled and
is routed to NMI.
Assert NMI on
SERR
Disabled
Enabled
If enabled, PCI bus system
error (SERR) is enabled and
is routed to NMI.
FRB-2 Policy
FRB2 Disable
Disable
Immediately
Never Disable
Allow 3 Failures
Controls the policy of the
FRB-2 timeout. This option
determines when the Boot
Strap Processor (BSP)
should be disabled if FRB-2
error occurs. Determines
when FRB2 stops.
Boot Monitoring
Disabled
Enabled
Enable or Disable the Boot
Monitoring Feature
Thermal Sensor
Disabled
Enabled
Determines whether the
temperature sensor
monitoring function is enabled
or disabled.
BMC IRQ
IRQ11
IRQ5
IRQ10
Disabled
Indicates the IRQ of the BMC
interrupt.
Post Error Pause
Disabled
Enabled
If enabled, the boot is
stopped when Post error
occurs.
AC Link
Power On
Last State
Stay off
Selects system power state
after AC loss.
Summary of Contents for EXPRESS5800/120Lf
Page 1: ... U s e r s G u i d e EXPRESS5800 120Lf ...
Page 2: ...NEC ...
Page 3: ... U s e r s G u i d e EXPRESS5800 120Lf ...
Page 9: ...Contents vii ...
Page 10: ...viii Contents ...
Page 36: ...1 20 System Overview ...
Page 99: ...Upgrading Your System 4 13 Figure 4 9 Replacing the Real Time Clock Battery ...
Page 146: ...4 60 Upgrading Your System Figure 4 60 Installing a Power Supply ...
Page 170: ...5 24 Problem Solving ...
Page 171: ...A Technical Specifications Server Unit ...
Page 174: ...A 4 Technical Specifications ...
Page 175: ...B Connectors Overview External Device Connector Pin Information ...
Page 190: ...10 Glossary ...
Page 196: ...Index 4 ...
Page 197: ...xx ...
Page 198: ... 456 01575 N00 ...