Table 16-4. Serial Interface Channel 0 Interrupt Request Signal Generation
Serial Transfer Mode
WUP
WAT1 WAT0
ACKE
Description
3-wire or 2-wire serial I/O mode
0
0
0
0
An interrupt request signal is generated each time 8 serial
clocks are counted.
Other than above
Setting prohibited
SBI mode
0
0
0
0/1
An interrupt request signal is generated each time 8 serial
clocks are counted (8-clock wait).
1
After address is received, if the values of the serial I/O shift
register 0 (SIO0) and the slave address register (SVA)
match, an interrupt request signal is generated.
Other than above
Setting prohibited
I
2
C bus mode (transmit)
0
1
0
0
An interrupt request signal is generated each time 8 serial
clocks are counted (8-clock wait).
Normally, during transmission the settings WAT1, WAT0
= 1, 0, are not used. They are used only when wanting
to coordinate receive time and processing systematically
using software. ACK information is generated by the
receiving side, thus ACKE should be set to 0 (disable).
1
1
0
An interrupt request signal is generated each time 9 serial
clocks are counted (9-clock wait).
ACK information is generated by the receiving side, thus
ACKE should be set to 0 (disable).
Other than above
Setting prohibited
I
2
C bus mode (receive)
0
1
0
0
An interrupt request signal is generated each time 8 serial
clocks are counted (8-clock wait). ACK information is
output by manipulating ACKT by software after an interrupt
is generated.
1
1
0/1
An interrupt request signal is generated each time 9 serial
clocks are counted (9-clock wait). To automati
cally generate ACK information, preset ACKE to 1 (enable)
before transfer start. However, in the case of the master,
set ACKE to 0 (disable) before receiving the last data.
1
1
1
1
After address is received, if the values of the serial I/O shift
register 0 (SIO0) and the slave address register (SVA)
match, an interrupt request signal is generated.
To automatically generate ACK information, preset ACKE
to 1 (enable) before transfer start.
Other than above
Setting prohibited
Remark
ACKE: Bit 5 of serial bus interface control register (SBIC)
Summary of Contents for 78014Y Series
Page 2: ...www DataSheet4U com 2 MEMO...
Page 8: ...www DataSheet4U com 8 MEMO...
Page 22: ...www DataSheet4U com 22 MEMO...
Page 30: ...www DataSheet4U com 30 MEMO...
Page 34: ...www DataSheet4U com 34 MEMO...
Page 62: ...www DataSheet4U com CHAPTER 2 OUTLINE PD78014Y Subseries 62 MEMO...
Page 78: ...www DataSheet4U com CHAPTER 3 PIN FUNCTION PD78014 Subseries 78 MEMO...
Page 94: ...www DataSheet4U com CHAPTER 4 PIN FUNCTION PD78014Y Subseries 94 MEMO...
Page 170: ...www DataSheet4U com CHAPTER 7 CLOCK GENERATOR 170 MEMO...
Page 222: ...www DataSheet4U com CHAPTER 9 8 BIT TIMER EVENT COUNTER 222 MEMO...
Page 230: ...www DataSheet4U com CHAPTER 10 WATCH TIMER 230 MEMO...
Page 262: ...www DataSheet4U com CHAPTER 14 A D CONVERTER 262 MEMO...
Page 318: ...www DataSheet4U com CHAPTER 15 SERIAL INTERFACE CHANNEL 0 PD78014 Subseries 318 MEMO...
Page 408: ...www DataSheet4U com CHAPTER 16 SERIAL INTERFACE CHANNEL 0 PD78014Y Subseries 408 MEMO...
Page 446: ...www DataSheet4U com CHAPTER 17 SERIAL INTERFACE CHANNEL 1 446 MEMO...
Page 472: ...www DataSheet4U com CHAPTER 18 INTERRUPT FUNCTIONS AND TEST FUNCTION 472 MEMO...
Page 502: ...www DataSheet4U com CHAPTER 22 PD78P014 78P014Y 502 MEMO...
Page 520: ...www DataSheet4U com CHAPTER 23 INSTRUCTION SET 520 MEMO...