MoniMax 5100T 7. Appendix
7-
24
Error Code
Cause
Handling
971D100
Partial dispense from cassette #1
1. Check the replenished amount and replenish
2. Check the notes in cassette #1
971D200
Partial dispense from cassette #2
1. Check the replenished amount and replenish
2. Check the notes in cassette #2
971D300
Partial dispense from cassette #3
1. Check the replenished amount and replenish
2. Check the notes in cassette #3
971DX00
In case partial bills dispensed by
dispensing demand when Partial
Dispense option is on.
☞
“X” means
cassette number.
9740000
Cash Dispenser communication failure
during COM port open.
9740020
Failed to create file
9740025
Failed to copy file
9740101
In case incorrect cassette type is set.
9740102
In case nonexistent Note Index is set.
9741100
When sensing CS2 Dark (Error code,
400FF00 is subdivided by location of
sensor.)
9741400
When sensing CS4A Dark (Error code,
400FF00 is subdivided by location of
sensor.)
9741800
When sensing CS4B Dark (Error code,
400FF00 is subdivided by location of
sensor.)
9742100
When sensing CS21A,B Dark (Error
code, 400FF00 is subdivided by location
of sensor.)
9742800
When sensing CS13 Dark (Error code,
400FF00 is subdivided by location of
sensor.)
9743B00
When sensing CS15A,B Dark (Error
code, 400FF00 is subdivided by location
of sensor.)
9744700
Cash picking-up fail while cash in
cassette #1 is enough
9745B00
Cash picking-up fail while cash in
cassette #2 is enough
9746B00
When sensing CS31A,B Dark (Error
code, 400FF00 is subdivided by location
of sensor.)
9747B00
When sensing CS41A, B Dark (Error
code, 400FF00 is subdivided by location
of sensor.)
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...