MoniMax 5100T 7. Appendix
7-
18
Error Code
Cause
Handling
4003400
Error of double notes detecting
sensor(CS5_1) for initializing
1. Check CS5_1 Sensor Cable
2. Check second Dip Switch in CDU B/D
3. Change CS5_1 Sensor
4003600
Error of CS 2, CS13 sensor during
initialization
1. Check note jam at CS2 and CS13 sensor
2. Clean CS2 and CS13 sensors
3. Reconnect CS2 and CS13 sensors
4. Replace CS2 and CS13 sensor
4003700
Error of 2 sheets detecting
sensor(CS5_1/CS5_2) for dispensing
1. Check note jam at CS5 sensor
2. Clean CS5 sensor
3. Reconnect CS5 sensors
4. Replace CS5 sensor
4003800
SRAM check error
1. Reboot ATM
2. Replace PCB on cash dispenser
4003900
Abnormal operation of the gate solenoid
during initialization or before dispensing
bill
1. Initialize after removing notes or dust over Gate
2. Check CS3 Sensor BKRT
3. Check CS3 Sensor Cable
4. Exchange Sensor after abnormal operating CS3
Gate detecting Sensor
5. Exchange Reject Solenoid 1
4003A00
This error occurs when the number of
demanded bills are more than 5 in
dispensing command for test
1. Check command that CDU is received
2. Check CDU EP ROM Version or specification
4003B00
CS15A, CS15B dark detection error
during initialization.
1. Remove notes or dust in existence CS15A
Sensor
2. Check CS15A Sensor Cable
3. Exchange Sensor after abnormal operating
CS15A Sensor
4004000
Taking out a cassette during dispensing
bills.
1. Push the cassette until making “click” sound
2. Check the catcher inside cassette guide
4004100
Error if re-driving is over 5 times during
separated rejection
1. Check notes in Reject Box
2. Rearrange notes in Cassette
3. Remove dust in CS15AB, CS31AB, CS41AB
CS1AB Sensor
4. Check dust existing in CS5 Sensor Guide
5. Check dust existing in Main Motor Encoder Slit
6. Check index value of notes each cassette
4004200
This error occurs when CS13 (the
number of dispensed bills) is smaller than
the number of demanded bills.
1. Check notes dispensed and rejected
2. Remove notes jammed in CDU
3. Remove dust in CS13 Sensor
4. Exchange sensor after abnormal operating CS13
Sensor
4004300
This error occurs when the rejected bills
are more than 10 during dispensing.
1. Check notes in Reject Box
2. Rearrange notes in Cassette
3. Remove dust in CS1AB, CS15AB, CS31AB,
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...