Error Code
Cause
Handling
400BC00
Communication error – Command Length
doesn’t match.
400BE00
Bill pickup sensor(CS1, CS15)
recognized has a hole and CS4 sensor
detects it or CS4 snesor detects the
gap too close
400C700
Something is detected on CS12 sensor
during dispensing bills or initialization.-
MB TTWn
400C800
Something is detected on CS14 sensor
during dispensing bills or initialization.-
MB TTW
400C900
Something is detected on CS14 sensor
after dispense operationn
400CC00
Bill is remained on the sensor in front of
cassette during resetting.
400D000
Bills are passed on CS13~CS12 sensor -
Timeout[Jam], MB TTW
400D100
Bills are passed on CS12~CS14 sensor -
Timeout[Jam], MB TTW
4DN0000
Cash Dispenser communication failure
during sending command to cash
dispenser
4DN0100
Cash Dispenser communication failure
during receiving command to cash
dispenser
4DN8100 Communication
error
of
Shutter
9712000
Failed to create file
1. Reboot ATM
2. Reinstall software
3. Replace hard disk drive
9712100
Failed to read file
1. Reboot ATM
2. Reinstall software
3. Replace hard disk drive
9712200
Failed to write file
1. Reboot ATM
2. Reinstall software
3. Replace hard disk drive
9712300
Failed to close file
1. Reboot ATM
2. Reinstall software
3. Replace hard disk drive
9712400
Failed to delete file
1. Reboot ATM
2. Reinstall software
3. Replace hard disk drive
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...