MoniMax 5100T 7. Appendix
7-
44
F. Electronic Combination Lock
F.1 Cencon Lock
Initial Operating Instructions
Each lock is shipped from the factory in Shelved Mode, operating on a standard combination (50-25-
50). The “one time only” combination does not function when the lock is in this condition. The correct
opening procedure for a new lock is :
z
Turn the Dial left (CCW) until the letters “EC” (Enter Combination) appear on the LCD
z
Enter the factory combination of 50-25-50 by sequentially pressing those six buttons. The LCD will
display these number as they are entered.
z
When the combination has been correctly entered, the LCD will read :OPr” meaning “Open right.”
z
Turn the Dial right (CW) until it stops. The lock’s bolt is now retracted and the lock is open.
z
Turning the Dial left (CCW) will extend the lock’s bolt
Try this several times until you are comfortable with the operation of the lock.
Change Shelved Mode Combination
For System 2000 Locks with a code level of 71, or greater, you may change the Shelved Mode
combination. You may change the default Factory Combination of 50-25-50 to a new combination to
be used while the lock is still in Shelved Mode. Once you have changed the combination for the first
time, you may want to change the combination again to a different Shelved Mode combination. You
can even change it back to the Factory combination of 50-25-50
Required Items: Change Key, Current Shelved Mode Combination
Note: You can only change the Shelved Mode combination while operating in Shelved Mode. Once a
lock is “activated” in any mode, the Shelved Mode combination returns to the Factory Default of 50-25-
50
To change the Shelved Mode combination:
1. Power Lock -> EC
Turn the Dial to the left (CCW) until “EC” (Enter Combination) is displayed.
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...