MoniMax 5100T 7. Appendix
7-
30
E.6 Miscellaneous
Error Code
Cause
Handling
1030100
Key data error from host
1. Contact to host
7000100
It’s impossible to read the version after
transferring to the CduSetup menu.
7000200
It’s impossible to read the version after
CDU Setup.
7000300
User’s setting values are different from
the actual written setting value.
9701010
Communication fail between PIN driver
(PIN SP) and pinpad
1. Check communication cable or com port is not
connected
9701012
Command sending fail to pinpad
1. Check communication cable or com port is not
connected
9701016
Data receiving fail from pinpad (EPP)
1. Check if communication cable or com port is
not connected
9701017
Data sending fail from pinpad (EPP)
1. Check if communication cable or com port is not
connected
9701031
Pinpad (EPP) configuration data reading
error
1. Reboot ATM
2. Re-install software
9701040
Failed to produce Thread for pinpad
(EPP)
1. Reboot ATM
2. Re-install software
9701060
Failed to create buffer for pinpad (EPP)
1. Reboot ATM
2. Re-install software
9701068
MapView of File Fail in Create
ShareMemory Method for EPP
1. Initialize Pin SP.
2. Call your attendant
9701070
Create Mutex Fail for SIU(Sensor)
1. Initialize Pin SP.
2. Call your attendant
9701102
COM handle is null for EPP
1. Initialize Pin SP.
2. Call your attendant
9701111
BCC error from pinpad (EPP)
1. Reboot ATM
2. Replace pinpad
9701150
Pinpad (EPP) is down when it receives
an 'Initializing’ command
1. Reboot ATM
2. Replace pinpad
9701151
Pinpad (EPP) is down when it receives
an 'Get Status' command
1. Reboot ATM
2. Replace pinpad
9701152
Pinpad (EPP) is down when it receives
an 'Clear Func Key' command
1. Reboot ATM
2. Replace pinpad
9707082
Failed the message transmission for the
fire event for VFD
ex) After connection is closed, an event
for the previous command is arrived.
It is a software error. On AP logic, check the event
for the command executed before closing
connection.
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...