MoniMax 5100T
6. Operator Function
6- 7
z
5. 5 Reset Configuration ID
P L E A S E
W A I
T . .
C O M P L E T E D
* Cancel Key to return
Reset configuration ID to download configuration data from host
z
5. 6 Denomination
* Cancel key to return
C S T 1 :
$ _
P L E A S E
W A I T . . .
C O M P L E T E D
IF CST = 1
N E W
V A L U E
_
* Cancel key to return
C S T 1 :
$ _
C S T 2 :
$ _
P L E A S E
W A I T . . .
IF CST = 2
N E W
V A L U E
_
N E W
V A L U E
_
* Cancel key to return
036
C O M P L E T E D
* Cancel key to return
Val + ENT
Val + ENT
Val + ENT
When LCU mode is used, each cassette must be set with the correct note type defined by
Data Processor
z
5.7
NoteValue
* Cancel Key to return
T Y P E
A : $ _
T Y P E
B : $ _
T Y P E
C : $ _
N E W
V A L U E
_
N E W
V A L U E
_
N E W
V A L U E
_
T Y P E
D : $ _
C O M P L E T E D
* Cancel Key to return
N E W
V A L U E
_
Val + ENT
Val + ENT
Val + ENT
Val + ENT
There are four Note Types in NDC - NoteType1(=A), NoteType2(B), NoteType3(C), and
NoteType4(D) – and 8 Note Types in Diebold 91x – A,B,C,D,E,F,G, and H. The currency
and denomination must be set for each note type, and the correct information for this must
be informed from Data Processor. Here are two scenarios.
Scenario #1. A=USD 5, B=USD 10, C=USD 20, D=Not Used
< SET NOTE VALUE >
a. Enter 5 for note type 1(=A), and press ENTER
b. Enter 10 for note type 2(=B), and press ENTER
c. Enter 20 for note type 3(=C), and press ENTER
d. Press ENTER for note type 4(=D)
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...