4) RMS IP SETUP function is to set up information of host to connect with RMS. If you press
each button on this menu, you can set up various information.
[Touch Machine]
[No Touch Machine]
Below items are to set up to communicate with RMS when supporting TCPIP
- USE URL function is to set up RMS address as IP or URL. If setting value is “ENABLE”, use
URL as RMS address. Otherwise, use IP as RMS address.
- RMS CONNECTION TYPE function is to set up whether to connect from ATM to RMS, or
from RMS to ATM. If setting value is “ACTIVE”, connect from ATM to RMS. Otherwise,
connect from RMS to ATM.
- NAME function is to set up RMS address. If “USE URL” is “ENBLE”, input URL of RMS. Up
to a maximum of 50 characters. Otherwise, input IP of RMS. Input 15 characters such as
XXX.XXX.XXX.XXX.(Refer to display for the details)
- RMS SEND INTERVAL function is to set up the time to send the status of the ATM to the
RMS periodically. Setting up the hours as the unit and setting up 4 hours as default. Be able
to input 1~24.
- ATM LISTENING PORT function is to set up required port number when connecting from
RMS to ATM. Setting up “5555” as default.
- RMS LISTENING PORT function is to set up required port number when connecting from
ATM to RMS. Setting up “9999” as default.
5) The PASSWORD function is used to set the RMS password to connect to ATM from RMS.
6) RMS CALL BACK OPTION function provides a function for only permitted ATM to connect to
RMS. The CALL BACK EN/DISABLE function is to set up whether to use RMS CAL BACK
function. If setting value is “ENABLE”, ATM makes a call to RMS using phone number
Summary of Contents for MoniMax 5100T
Page 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Page 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Page 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Page 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Page 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Page 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Page 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Page 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Page 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Page 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Page 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Page 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Page 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Page 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Page 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Page 277: ...MoniMax 5100T 7 Appendix 7 61...